Title: SmartVFD HVAC, BYPASS, NXL, NXS Introduction
1- SmartVFD HVAC, BYPASS, NXL, NXS Introduction
2Honeywell SmartVFD Today and tomorrow
SmartVFD BYPASS SmartVFD HVAC Disconnect 2-Contac
tor 3-Contactor Auto-Bypass HOA
SmartVFD COMPACT 480 VAC .5-7.5HP 208/230VAC,
1in, .25-3HP 208/230VAC, 3in .25-3HP 115VAC,
1in .15-1.5HP 575Vac, 1HP-7.5HP NEMA1 Kit Modbus
Std
- SmartVFD HVAC
- 480 VAC 1.5-250HP
- 230VAC 1125HP
- 575VAC - 1-150HP
- Graphic Interface
- Std fieldbus protocals
3SmartVFD HVAC
- Intuitive Interface
- Easy Commissioning
- Standard Communication
- Reliable Protection
- Effective Operation/Monitoring
The SmartVFD for Smart Buildings
4Intuitive Interface
- High resolution
- Intuitive commissioning
- Manual in keypad
- Help screens
- Real time clock
- Local/Remote Button
- Memory in keypad
Intuitive, Effective, Consistant SMART
5Easy Communications
- Standard
- RS485
- BACnet
- N2
- Modbus
- Ethernet
- Modbus/TCP
- BACnet/IP
- Option Cards
- LonWorks
- Profibus
- CANopen
- DeviceNet
- Ethernet
Built-in Communications
6Built-In Protection
- DC Choke
- Built in resistors for upfront protection
- Varnished boards
- RFI filter standard
- Built in Fan
- NEMA12 extra fan
Harmonic, RFI, Environmental Protection
7SMART Software
- Start-up Wizard Pump/Fan
- Power loss ride through
- Fire mode
- Pump and Fan Cascade
- Ramp Time Optimizer
- Maintenance Counters
- Pump Soft Fill
- 2 PID Controllers
The SmartVFD for Smart Buildings
8SmartVFD BYPASS
- Low total installed cost
- Compact size
- Easy component access
- NEMA 1, 12, 3R
- All configurations
- Disconnect
- 2-contactor
- 3-contactor
- 3-contactor with AutoBypass, HOA
9Features
10Bypass Options
11Smart VFD HVAC Mechanical Construction MR4
- Rectifying ,
- brake and IGBT
- IP21 or 54
- Plates and
- sealing
12Smart VFD HVAC Cabling
- Sealing
- No throughput clamps needed in IP21
- No throughput clamps needed in IP54
- EMC
- 360 grounding with easy clamps inside the
drive (consertrig) - Input cables
- MCMK no shield needed
- Motor cables
- Max lenght
- MR4 100m
- MR5 and MR6 150m
- MR7 200m
- C2 MCCMK and C3/IT MCMK
- Grounding
- 2 PE wires needs to be connected to ground to
fulfill EN61800-5-1. - Fuses and cable sizes MR4-9
- Chapter 4.1.1.X in installation manual
13Smart VFD HVAC Fieldbus RS-485
- RS485 2 Wires always included in Vacon 100 HVAC
- BACnet
- N2
- Modbus
- RS485 4 Wires
- Keypad
- PC Tools
14Smart VFD HVAC Fieldbus Ethernet
- Ethernet module is integrated to the main
processor - Supported General Protocols
- TCP/IP (basic protocol)
- DHCP, AUTOIP, IPConfig
- FTP (Future Option)
- HTTP, simple web browser interface (Future
option) - Supported Industrial Protocols
- Modbus/TCP
- BacNet IP
- Vacon HMI protocol (for PC tool usage)
- Ethernet/IP and Profinet (Future option)
- Cable max lenght 100m (to switch)
15Smart VFD HVAC Control Board
- ARM9 Processor (200MHz)
- Flash Memory 32Mb
- RAM Memory 128Mb
16 www.honeywell.com