Title: Three-Phase Power Quality Measurement Products PA-9
1Three-Phase Power Quality Measurement
ProductsPA-9
Plus
2PA-9 DESIGN OBJECTIVES
Plus
- Use The Latest Technology To Deliver the Highest
Performance At Lowest Price. - One of the Most Powerful Digital Signal
Processors. - Co-Microprocessor Design.
- Utilizes Low Cost, Hi-Density Digital Camera
Memory. - Utilizes High Performance Graphical Display.
- Update Future Features via Flash Reprogrammable
Firmware - A Worldwide Product
- CE Approved (Completed with current PA-9Plus)
- Expand to meet Relevant IEEE/IEC Standards
- EN 50160, 61000 4-30, 61000 4-15 and IEEE 1159
- Support multiple languages
- English and French now, with Spanish to follow
- Others as required
3Result The PA-9 Power Analyzer
Plus
- Evolving from
- 17 Years Experience Manufacturing Power Quality
Monitoring Products - Listening To Suggestions From Our 600 Customers
- Experience From Our Very Successful Products like
the PA-9 and PA-7 Power Analyzers (1600
instruments installed). - Our Intent
- Extend This Success Worldwide to Utility and
Industrial Marketplaces
4 Plus
The PA-9 Exterior
5 KEY FEATURES
Optional Data Transfer Card
Mouse Type Navigation System
DB9 RS232 Port
Simplified Instruction Sheet
Aux Power Input
6 KEY FEATURES
- 4 (Differential) Voltage/5 Current Channels 9
Total Inputs - Range Voltage 600V AC or DC
Current (0-6000 Amps) Based on CT Chosen
(20-6000 Amps) - 256 Samples/Cycle Simultaneously Read On Every
Input Channel (TRMS through 63rd Harmonic) - Sub-Cycle Event Capture to 65 Microsecond Events
- All Common Connection Configurations Supported
for Power Measurements - Immediate Local Info and Analysis using onboard
Graphical Display (Waveforms/Charts/Harmonics/Phas
ors/Flicker) - Instrument Self-Powers from Either Phase A
Voltage (90-600v AC ,110-600v DC) OR Secondary
Power Input Channel - Field-Update Firmware via Internet
7 KEY FEATURES
- 4 Simultaneous Recordings
- RMS Voltage/Current (Long Term Trend)
- Out of Limits Log (for Sag/Swell/Harmonics/Transie
nt Events) - Waveforms (by Event, THD/TDD/Harmonic Trending,
or Time) - All Power Flow Parameters
- 12MB Non-volatile Internal Memory (No Batteries
or Moving Parts Needed) - 115Kbps RS-232 Maintenance Port
- Optional Internal Modem
- Optional Removable Compact Flash Transfer Memory
(No PC Required to Program Instrument or Retrieve
Data) - Remotely Analyze Data prior to Download, and
Selective Data Download Capabilities - Weatherproof Package Portable, Sturdy, and
Rugged
8 IEC SPECIFIC KEY FEATURES
- EN 50160 Measurements
- Flicker Per IEC 61000-4-15 For Both 50 And 60 Hz
- Display Pst And Plt Values. Pst On A Sliding One
Minute Interval - Dynamic Frequency Measurements from 20 To 70 Hz
- Trending Of Frequency Based On A Minimum Sliding
5 Cycle Period - Ideal for Generator Startups
- Trending Of Harmonics Up To The 63rd Harmonic
- RMS Trending Of All IEC Report Parameters
- Low Voltage 4th Channel Standard 0.1 Volt To 500
Volts Peak - Language Support In Pa-9 Plus And Metrosoft
- English and French Available First, Spanish To
Follow - New Metrosoft Supports All New Features With
Firmware Included - Optional New Report Generator For Customer
Specific Reporting
9 RMS Recording
- Parameters to consider
- Fast Sampling Rate (Fixed at 256/cycle)
- RMS Response Time (or Integration Time) User
Settable To 1 cycle or longer. - Storage Interval
- User Settable 1 cycle to 4 Hours. Save Min RMS,
Max RMS, Overall RMS per Storage Interval. - Standard Cycle by Cycle Recording Capability for
Motor Inrush Studies - Our Instrument Memory Recording Techniques
Conserve Memory and Guarantees Capture of Lowest
Highest Signal Values per Storage Interval.
10The Scan Line can move to display values in window
Notice the large current swells due to a
lightning strike
11 Out-Of-Limits Events Log
- User Sets Following Limits By Channel
- High/Low RMS Limits (both V I)
- Sub-Cycle Impulse Magnitude.
- THD
- Recorder Captures up to 1000 Events Outside of
User Preset Limits And Logs Them With Duration In
Out-Of-Limits Log.
12Stored DataEvent / Out of Limits Data
- Out of Limits- While recording, continuously
monitors for excedances of user defined limits
for upper lower V/I, sub-cycle (65uS), and
THD. - Monitors all connected channels, for analysis
between load / source side.
13 Waveform Capture
- Waveforms Are Captured Via
- Event Trigger
- Time Trigger
- THD/TDD/Individual Harmonic Trending
- User Trigger from Front Panel
- User Specifies Number of Pre-Trigger Cycles (Max
2) and Number of Post-Trigger Cycles To Capture.
14Instrument Front Panel Waveform Display
15Loss of Voltage After a Lightning Strike
16Applications for PA-9Waveform Capture - Motor
Inrush
Plus
- Waveform capture triggered on Rising Current
- Three phase chiller start-up inrush.
- Display all captured cycles on one screen.
(Inrush decay envelop) - Same click and drag zoom and scan line features.
17 Real Time Harmonic Analysis
- FFT Done Every 6 Cycles.
- Harmonic Analysis And Direction Of Harmonic Power
Flow Presented On Display. - Generally A Very Good Indicator Of The Harmonics
Source
18Harmonic Analysis In Software
Here we see we have a total THD of 55.5, with
the largest expected contributions from the
odd-ordered 5th, 7th, 11th, and 13th harmonics.
19 Demand Recording
- User Specifies Demand Interval, Fixed Or Sliding
Window, Configuration (Wye, Delta etc). - All Power Parameters Are Recorded (KW, KVAR, KVA,
pf, dpf etc). - Power Data Can Be Measured and Recorded As Fast
As Every Cycle
20Stored True RMS Voltage / Current
- Pa-9 can display
- MIN, MAX, and TRMS values for all channels for
entire test. (Press HOME, select Stored Data,
RMS Interval) - Trending graphs of any parameter (ex. VA MIN
trended over entire test) - MEGPA9IEC Software Tabular Report (right)
- MIN, MAX, RMS Reported at every storage
interval. - Data for trending graphs
- with scan line
- click and drag zooming (next)
21Demand Data (with power flow option)
- MEGPA9IEC Software allows
- Printing and exporting of text data reported
every storage interval - Trending graphs with click and zoom capabilities
- Scan line reporting and vector diagrams (next)
22Demand Graph with scan line feature and vector
diagram.
23MEGPA9IEC Software
- Complimentary 32-bit Software Package available
online (http//www.megger.com) - Compatible with Win 95/98/NT/2000/ME/XP
- Generates Extensive Graphs/Reports
- Supports Download by Exception
- Preview What Is Recorded Inside PA-9
- Download Only What Is Needed
- Enhanced Communications Via Serial or Modem
Connections - Provides Direct Export of Data to Other Windows
Applications EXCEL or WORD
24Hardware User Interface
- 115 Kbps communications port
- Optional Internal Modem
- Fully Graphical display
- View real time and stored data (text and
graphical) - 12 MB base memory
- Optional Removable Memory 64, 128, 256, 512MB
capable - PC Card Reader Included
- Large, tactile keypad for easy operation even
with gloves on.
25Hardware Packaging
- Rugged enclosure
- High impact
- Smaller package (13x10x6)
- NEMA 4X Weatherproof
- Lockable hasps
- Protective handles on input connector side.
- Lightweight (15 lbs./ 6.8 Kg.)
- Wide temperature range (-20C to 50C)
26Hardware Voltage Channels
- 4 Voltage Channels
- 150/600VAC DC auto-ranging.
- Safety banana jack inputs
- Right angle prevents accidental pull out
- Unfused Leads Standard, Fused Leads optional.
- Resolution .1 full scale.
- Accuracy .25 rdg .05 full scale.
27Hardware Current Channels
- 5 Current Channels
- Resolution .1 Full Scale
- Accuracy .25 rdg .05 range probe accuracy.
- Current probes
- CP-6000CE - 600/6000A
- Powered from PA-9!
- 1 reading accuracy!
- 20/100/1000 CTs available for Metering
Secondaries or Larger Current Loads - Optional Adapter cable mates most Legacy CTs to
the PA-9 Plus - On-site CT Selection Directly Without
Reprogramming.
28Hardware Power Supply
- 90-600VAC or 110-600VDC Operation.
- Power From V(A channel) or IEC Auxiliary Input
standard - No separate, regulated 120VAC power source
required - No need for Long Extension Cords or Step-Down
transformers - Internal, Rechargeable No-Maintenance Battery.
- Ride through 15 minute outage.
- 10 Year Non-Volatile Memory Data Retention.
- External Safety Ground Lug.
29Summary Unique Features
- No Other Single Instrument Combines All The
Following Features - 9 Channels (4V/5I). Measure AC or DC Voltage.
- Simultaneously Record RMS/Power/Waveforms.
- Capture Events As Fast As 65 Microseconds.
- Trigger Events on Current Inputs As Well As
Voltage. - Capture 2 Pre-trigger Cycles Many Post-trigger.
- 256 Sample/Cycle Rate FFT Every Few Cycles.
- THD/TDD/Individual Harmonics Trending
- Display Direction of Harmonic Power Flow.
- Selectively Download Explicit Data from Recording
Session - Recorder Simultaneously Stores up to 60 User
Defined Setups - Self-Power From Unregulated AC/DC Voltage being
Recorded. - Fully Weatherproof with Wide Industrial
Temperature Range.
30Key Front Panel Displays
- Store Up To 60 Field Selectable Setups.
- Modify CTs Settings In The Field
- Review Event Log On Site
31PA-9 Starter Kit
Plus
- Example Starter Kit includes
- PA-9 Plus, w/Full 12 MB internal memory
- Full RMS, Event, Power Flow, Energy, Flicker,
Harmonics, and Frequency Recording Capabilities - Removable Memory Option with 64MB Compact Flash
Card - (3) 600/6000 Amp flexible current probes
(powered from instrument ) - ca-pa9-11- kit of 4 (unfused) voltage cables with
alligator clips and a set of neutral jumper
cables - ca-rs232 - Communications cable
- SC-PA9 soft sided carry case
- MEGPA9IEC - 32 bit Windows 95/98/NT/2000/ME/XP
Software - Complete 1 Year Warranty
32 - Thank You For The Opportunity to Show You This
Remarkable Instrument! - For more information, please contact us at
- http//www.megger.com