Title: PERMITS


1
PERMITS INSPECTIONS DEPARTMENT
  • 2003 INTERNATIONAL RESIDENTIAL CODE
  • IRC

2
IMPORTANT DATES
  • New codes will affect all plans submitted after
    September 1, 2005
  • Any existing project or plans submitted prior to
    September 1 will be reviewed and inspected under
    old codes
  • Inspections for permits issued after September 1
    will be conducted under the new codes effective
    November 1, 2005

3
IRC 2003 SECTION 100
CODE SECTION
DESCRIPTION
  • PLAN REVIEW
  • CERTIFICATION OF MAIN STRUCTUARAL ELEMENTS AND
    COMPONENTS REQUIRED FOR APPROVAL
  • COMPLETE PLANS MUST HAVE
  • 4 ELEVATIONS FRONT, REAR, BOTH SIDES
  • CROSS SECTION TO ALLOW FOR ADEQUATE DETAIL
  • FLOOR PLANS FOR ALL LEVELS
  • ONLY MINOR REVISIONS ALLOWED
  • R506.2.1 GARAGE SLABS EXCEEDING REQUIREMENTS MUST
    BE ENGINEERED
  • gt2CLEAN SAND OR GRAVEL 6 BASE

4
IRC 2003 SECTION 100
CODE SECTION
DESCRIPTION
  • R105.7 BY LOCAL AMENDMENT
  • THE PERMIT HOLDER OR HIS AGENT SHALL POST THE
    PERMIT INSPECTION RECORD ON THE JOB SITE IN AN
    ACCESSABLE AND CONSPICUOUS PLACE TO ALLOW THE
    BUILDING OFFICIAL TO MAKE THE REUIRED ENTRIES

5
(No Transcript)
6
IRC 2003 SECTION 300
CODE SECTION
DESCRIPTION
  • R301.5 DECK LOADS
  • REDUCED FROM 60 PSF TO 40 PSF
  • R303.3 BATHROOM MECHANICAL EXHAUST
  • MINIMUM 50 CFM INTERMITENT
  • MINIMUM 20 CFM CONTINUOUS
  • FANS MUST BE VENTED TO EXTERIOR OF
    BUILDING THROUGH ROOF OR GABLE END AND
    TERMINATE WITH AN APPROVED CAP

7
IRC 2003 SECTION 300
CODE SECTION
DESCRIPTION
  • R305 MINIMUM CEILING HEIGHT FOR
    HABITABLE AREAS
  • REDUCED FROM 76 TO 70
  • R308.4 SAFETY GLAZING
  • WINDOWS IN AROUND STAIRWAYS LANDINGS
    WITHIN 60 OF FLOOR
  • R309 GARAGE FIRE SEPARATION
  • ½ DRYWALL STANDARD
  • 5/8 TYPE X ON CEILING WITH ROOM ABOVE PLUS
    ½ ON ALL SUPPORTING WALLS
  • 4 STEP DOWN IS NO LONGER REQUIRED FLOOR
    MUST SLOPE TOWARD DOORS OR DRAIN
  • 20 MINUTE RATED DOOR MIN. SELF CLOSING NO
    LONGER REQUIRED

8
IRC 2003 SECTION 300
CODE SECTION
DESCRIPTION
  • R310 EMERGENCY EGRESS (BEDROOMS)
  • WINDOWS
  • 24 CLEAR OPENING HEIGHT
  • 20 CLEAR OPENING WIDTH
  • 5.7 SQ.FT. NET CLEAR OPENING
  • IRC ADDRESSES SPECIFIC INFORMATION ON
    DESIGN OF WINDOW WELLS FOR EMERGENCY EGRESS

9
IRC 2003 SECTION 300
  • CODE SECTION
    DESCRIPTION
  • R310 EMERGENCY EGRESS (BASEMENTS)
  • EMERGENCY EGRESS REQUIRED FROM ALL
    BASEMENT AREAS (FUTURE HABITABLE SPACE)
  • BEDROOMS OR SLEEPING AREAS
  • DOORS, STAIRWAYS, BILCO DOORS, EMERGENCY
    WINDOWS ARE ALL ACCEPTABLE

10
THIS IS NOT AN APPROVED MEANS OF EGRESS !!!
11
IRC 2003 SECTION 300
CODE SECTION
DESCRIPTION
  • R311 MEANS OF EGRESS
  • ACCESSABLE STORAGE AREAS UNDER STAIRWAYS
    MUST BE DRYWALLED.
  • NO CHANGE IN STAIR REQUIREMENTS 8 1/4 MAX
    RISER 9 MAX TREAD
  • R312 GUARD RAILS/ HAND RAILS
  • MAXIMUM OPENING CHANGED FROM 6 TO 4

12
IRC 2003 SECTION 300
CODE SECTION
DESCRIPTION
  • R313.1 SMOKE DETECTORS
  • MUST BE INSTALLED
  • ON ALL FLOORS
  • IN ALL BEDROOMS
  • VICINITY OF ALL SLEEPING AREAS
  • R321.1 BUILDING ADDRESSES NOW REQUIRED
  • 4 HIGH FOR SINGLE FAMILY
  • 6 HIGH FOR MULTI-FAMILY
  • MUST BE CLEARLY VISIBLE FROM STREET

13
IRC 2003 SECTION 300
CODE SECTION
DESCRIPTION
  • R317 DWELLING UNIT FIRE SEPARATION
  • DUPLEX 1 HOUR SEPARATION
  • TOWNHOUSES (SEMI DETACHED)
  • 2 HR SEPARATION WALL WITH PARAPET OR
    INSTALLATION OF FIRE-RETARDENT SHEATHING 4
    ON EITHER SIDE OF SEPARATION WALL
  • NO OPENINGS PERMITTED WITHIN 4 OF
    SEPARATION WALL
  • NO SPRINKLER EXCEPTION

14
IRC 2003 SECTION 400
CODE SECTION
DESCRIPTION
  • R403.1.4.1 FROST DEPTH FOUNDATION
  • NOT REQUIRED FOR FREE STANDING ACCESSORY
    STRUCTURES lt 400 SQ.FT.
  • PERMITS ARE NO LONGER REQUIRED FOR
    ACCESSORY BUILDINGS UNDER 200 SQ.FT.

15
IRC 2003 SECTION 400
CODE SECTION
DESCRIPTION
  • R404.1 FOUNDATIONS
  • HOUSE LOCATION SURVEY REQUIRED BEFORE
    FOUNDATION INSPECTION
  • NEW TABLES BASED ON SOIL TYPE AND BACKFILL
    HEIGHT
  • SPECIFIC REINFORCEMENT REQUIREMENTS

16
IRC 2003 SECTION 400
CODE SECTION
DESCRIPTION
17
IRC 2003 SECTION 400
CODE SECTION
DESCRIPTION
  • R408.5.1 PIERS
  • MUST BE SUPPORTED BY EARTH ON ALL SIDES IN
    CRAWL SPACES
  • CANNOT BE FORMED ON TOP OF GROUND

18
IRC 2003 SECTION 400
CODE SECTION
DESCRIPTION
  • R406 WATER/DAMP PROOFING
  • WATERPROOFING ONLY REQUIRED WHEN PROOF OF
    HIGH WATER TABLE OR SEVERE SOIL CONDITION
    IS SUBMITTED
  • ENGINEERS REPORT REQUIRED BY
  • OPTION OF BUILDER
  • REQUEST OF INSPECTOR

19
IRC 2003 SECTION 500
CODE SECTION
DESCRIPTION
  • R502.8 SPANS, CUTTING, NOTCHING
  • BASICALLY THE SAME ONLY MINOR MODIFICATIONS
    TO TABLES
  • JOIST BLOCKING OVER GIRDERS
  • REQUIRED WHERE JOISTS DO NOT OVER LAP AT
    LEAST 3
  • EXAMPLE 12OC TO 16OC

20
(No Transcript)
21
IRC 2003 SECTION 600
CODE SECTION
DESCRIPTION
  • R602.3 STUD SPACING

22
IRC 2003 SECTION 600
CODE SECTION
DESCRIPTION
  • R602.3.1 STUD SPACING FOR WALLS gt 10
  • IRC SPECIFIES STUD SIZE SPACING FOR
    WALLS GREATER THAN 10 FOR VARIOUS LOADING
    SITUATIONS

23
IRC 2003 SECTION 700
CODE SECTION
DESCRIPTION
  • R7 WALL COVERINGS
  • EXTERIOR BRICK VENIER SUPPORT IRC OFFERS
    ALTERNATIVE DESIGNS THAT IF INSTALLED PER
    CODE ENGINEERS DESIGN IS NOT REQUIRED

24
(No Transcript)
25
IRC 2003 SECTION 800
CODE SECTION
DESCRIPTION
  • R7 RAFTERS AND JOISTS
  • CHANGES IN SPAN TABLES
  • RESULTS ABOUT THE SAME
  • ALLOWS FOR INTERPOLATION

26
IRC 2003 SECTION 800/900
CODE SECTION
DESCRIPTION
  • R802.10.5 TRUSS WALL CONNECTIONS
  • TRUSS CONNECTIONS REQUIRED
  • DESIGNED TO RESIST MIN. 175 POUNDS OF
    LIFT
  • R900.0 ROOF ASSEMBLIES
  • ICE PROTECTION
  • REQUIRED FOR SLOPES lt 412
  • 30 LBS FELT OR EQUIVELANT

27
IRC 2003 ENERGY CODE
CODE SECTION
DESCRIPTION
  • MARYLAND STATE ENERGY CODE
  • As part of the International Energy Conservation
    Code the state of Maryland has adopted the
    Maryland Energy Code with no local amendments
    allowed. At this time Washington County does not
    perform energy code inspections, with the
    exception of verifying proper installation, flame
    and smoke developed index on exposed insulation,
    but recognizes the importance of energy
    conservation.
  • R316.1 FLAME SPREAD INDEX lt 25
  • SMOKE-DEVELOPED INDEX lt 450
  • R318.1 VAPOR RETARDER SHALL BE INSTALLED
  • ON THE WARM-IN-WINTER SIDE OF
    INSULATION