SNS Fast Beam Loss Monitors Final Design Review - PowerPoint PPT Presentation

1 / 11
About This Presentation
Title:

SNS Fast Beam Loss Monitors Final Design Review

Description:

... Highest light output of any liquid (80% anthracene) Excellent light transmission (2.5m, min 1/e attenuation) High Flash point (48oC, 118oF) PMT ... – PowerPoint PPT presentation

Number of Views:78
Avg rating:3.0/5.0
Slides: 12
Provided by: MartinKe3
Category:

less

Transcript and Presenter's Notes

Title: SNS Fast Beam Loss Monitors Final Design Review


1
SNS Fast Beam Loss Monitors Final Design
Review
  • David M. Gassner

2
BLM System Design Features
  • Ion Chambers
  • Wide Dynamic Range (IC 6 Decades) (2 dn, 4 up)
  • Gain adjustment (per channel)
  • Beam intensities
  • Detector shielding
  • Response Time
  • Ion Chamber
  • Micro-second response. Data can be available for
    multi-turn, per cycle, and per second intervals.
  • Order of 5-10 turns to generate Permit Link Fail
    (35 KHz BW 10us)
  • FBLM, Liquid Cell/ PMT
  • Fast (ns), within turn loss data
  • Wide dynamic range
  • FBLM Test
  • LED mounted inside Scintillator/PMT assembly
  • Can be pulsed remotely

3
BLM Distribution
Total 18 FBLMs
4
HEBT Loss Monitors
169 meters BLM Location Quantity Quads 37 Co
llimator 2 Cavities 2 Dump
2 BIG 1 Moveable 8 FBLM Location
Quantity Upstream 1 Bend 1 Dump 1
5
Ring Loss Monitors
248 meter circumference BLM Location
Quantity Quad 44 Injection
7 Collimators 7 RF 5 Extraction
5 Moveable 7 FBLM Location
Quantity Injection 2 Straight Sec.
End 4 Bends 4 Extraction 2
6
RTBT Loss Monitors
150 meters BLM Location Quantity Quads
27 Collimators 4 Dump
2 Target 3 Moveable 4 FBLM
Location Quantity Extraction 1 Collimators 1
Target area 1  
7
Liquid Cell/Photo-Multiplier Loss Monitor
  • Detector
  • Available commercially from Bicron, Model MAB.
  • BC-505 Liquid (1,2,4 Trimethybenzene)
  • More Rad hard than plastics, (about 10Xs)
  • Highest light output of any liquid (80
    anthracene)
  • Excellent light transmission (2.5m, min 1/e
    attenuation)
  • High Flash point (48oC, 118oF)
  • PMT - Hamamatsu 2060, 10 stage.
  • Sensitivity on order of 100uC/R, Relative to
    itself.

8
Loss Signals
  • Fast Loss Monitor Applications
  • Fast instabilities
  • Kicker errors
  • Momentum errors
  • Beam in Gap
  • Ring wire scanner data
  • Two Modes
  • Integrated signal over bunch duration, read out
    via digitizer clocked revolution frequency.
  • Losses within bunch. Signals buffered and sent
    through wideband mux to fast digitizer (1 GS/s).

9
FBLM - Liquid Cell Photo Multiplier
10
Data Acquisition Control
  • Buffer Electronics
  • Wideband amp, drives two outputs.
  • Loss Data
  • All channels digitized through standard 60 MS/s
    14 bit ADC.
  • Selected channels at 1 GS/s via mux, (Example
    LeCroy 374 Scope)
  • Data transferred to high level via Channel
    Access.
  • Multiplexer for 1 GS/s
  • Keithley
  • 7001 High Density Switch system
  • 7016A 50 Ohm, Dual 1X4, 2 GHz Mux cards
  • LED Test Pulse
  • Remote control
  • Timing
  • HV Bias Control
  • EPICs Driver to ISEG VME based Bias Supply

11
HV Bias
  • ISEG HV Bias Supply
  • VME High Voltage Power Supplies in 2 slot width
  • 1 channel and 2 channel versions in same
    dimensions
  • LCD display for voltage or current
  • variable rate of change of output voltage
  • switched polarity
  • integrated protection and control circuits
  • output overload and short circuit protected
  • SHV connector on front side
  • Full control via VMEbus
  • EPICs drivers
  • 1.2k/channel
  • Model VHQ 202M, 0-2kV, 3mA