5(No Transcript)
6 Acute Respiratory
Distress (COPD, Asthma) ?1. Initiate O2 via
Mask or Cannula according to distress 2. ALS
Crews initiate CPAP 15-25 L/min (5-10 cm H2O)
according to distress. 3. Administer
Albuterol up to 5.0 mg via nebulizer at 8-10 L/
minute. 4. Monitor EKG and Vital
signs. 5. Initiate IV with saline lock or NS
at KVO rate. 6. Contact Medical Control
Pediatric Doses (ages 2-12) Albuterol up
to 5.0 mg via Nebulizer at 8-10 l/min.
7(No Transcript)
8Boussignac CPAP System
- Select the appropriate size face mask for your
patient - - Child Mask (Size 3)
- - Small Adult Mask (Size 4)
- - Medium Adult Mask (Size 5)
- - Large Adult Mask (Size 6)
9Boussignac CPAP System
- Set Oxygen flow to deliver CPAP in cmH2O of water
pressure - - 15 liters 5cmH2O
- - 20 liters 7.5 cmH2O
- - 25 liters 10 cmH2O
10Boussignac CPAP System
- Connect funnel end of Green Oxygen Tubing to an
O2 source capable of delivering flow up to 25
liters/min. - This provides the full range of CPAP needed for
clinical use (5-10cmH2O). - Typically a D size cylinder in the field.
11Boussignac CPAP System
- Insert white end of the Boussignac CPAP into the
face mask.
12Boussignac CPAP System
- If required, insert a pressure manometer between
the Boussignac CPAP and the face mask.
13Boussignac CPAP System
- Explain to the patient how the Boussignac CPAP
will help their breathing. - Gently hold the mask to the patients face
insuring a good face/mask seal. - Turn the flow control device to the desired
liters/min, generally 15 l/min, to begin the
CPAP. - Gradually adjust the flow to achieve the desired
level of CPAP.
14Boussignac CPAP System
- Secure the Boussignac CPAP System to the patient
with the head strap. - Check around the mask for any leaks.
- Adjust the mask and/or head strap accordingly.
15Boussignac CPAP System
- If the patient requires suctioning of the oral
cavity, insert French size suction catheter
through the open end of the Boussignac CPAP
System. - CPAP pressure will not be affected.
16Boussignac CPAP System
- CO2 can be monitored with either a nasal cannula
or an in-line CO2 adapter.
17Boussignac CPAP System
- When transporting the patient in the ambulance,
connect the Green Oxygen delivery tube to the
wall Oxygen in the vehicle.
18(No Transcript)
19Boussignac CPAP System Nebulizer
- Fill the nebulizer with the prescribed
medication.
20Boussignac CPAP System Nebulizer
- Insert the 22 mm male end of the nebulizer into
the face mask. - Insert the 22 male end (white) of Boussignac CPAP
into the nebulizer.
21Boussignac CPAP System Nebulizer
- Connect the funnel end of the nebulizers gas
delivery tube to a gas source. - Turn on gas source to 6 liters/min. to power the
nebulizer. - Maintain O2 flow to Boussignac CPAP System at 15
l/min. (5cmH2O).