Title: AGENDA


1
Features and Mysteries of BOL chambers
  • AGENDA
  • Xray tomograph -BOL0 results (Martin)
  • BOL0 and BOL2 Features (Graziano)
  • Discussion (All)

2
BOL0 - Hypothesis
  • OBSERVATIONS BOL0
  • Y-pitch between inner wire-layers 20um too large
  • Y-Pitch between outer wire-layers only slightly
    too large
  • Y-Pitch between multilayers 75um too small
  • Hypothesis
  • Glue shrimp between tubes and spacer?
  • (2x500um glue gap)
  • --gt measured lt5um effect for 1mm gap
  • Xplate deforms during gluing. In particular the
    flange
  • --gt presented today
  • Additionally
  • Re-analysis of BOL0 construction RASNIK readings
    cumulative effects lead to better agreement!

s
3
Floppy Xplate wrt tubes
Rotation of unknown relative size
_at_longbeam
Longbeam constraints body Xplate locally
Tube-length bends body
Tube direction bends flanges
Away from longbeam
s
4
Sag Adjustment
Rotation of unknown relative size
Longbeam constraints body Xplate locally
Tube-length constraints flanges
Tube direction bends flanges
Away from longbeam flange bends differently!
BOL0 is scanned with sag-adjustment (partially)
on! (Longbeam sag is assymetric in BOL0)
When we are optimistic deformation is symmetric
for up/down ML.
s
5
Sag Compensation
Rotation of unknown relative size
Longbeam constraints body Xplate locally
Tube-length constraints flanges
Tube direction bends flanges (temporary)
s
6
XP deformation
During BOL2 construction, the flange of the HV
xplate was measured with micro-gauges LBF
Longbeam- Flange BF Body- Flange
For now, BOL2 is still equipped with gauges,
located on the inner side of the HV-xplate
s
7
Gluing BOL-0
  • Stability Xplates during gluing

Layer 1
Yrasnik2 x Sag
Layer 1 dSag7um
Layer 2
Start glue
Layer 3
Layer 2 dSag10um
  • The sag of the xplates in layer 1 and 2 change in
    time.
  • Layer 3,4,5,6 Sag stable

s
8
Sag Compensation
BOL2
Layer 1
Start -15/2 um
  • During gluing of
  • layer 1 and 2, significant changes in xplate sag
    were observed
  • In-stable reduction valves?
  • Effect of glue viscosity?

End -38/2 um
Layer 2
Start 30/2 um End 50/2 um
1 deg
s
9
Conclusions
  • OBSERVATIONS BOL0
  • Y-pitch between inner wire-layers 20um to large
  • Y-Pitch between outer wire-layers only slightly
    to large
  • Effects largely explained by RASNIK measurements
    during construction.
  • Flange deformation of order 10um could be
    baked in.
  • Y-Pitch between multilayers 75um to small
  • Flange deformations of this order are certainly
    observed. However these deformations appear
    symmetric and elastic.
  • Needs more study -gt effects of kinematic mounts
  • direct -in situ- measurement dY of Frascati comb
    and towers

s
10
Test _at_CERN inTomograph (BOL0)
Analysis of Martin Woudstra
Wire positions RMS 16mm
s
11
Parallelogram-ness
For stability bare spacer
Checks distance wrt Comb _at_ RO side
BOL
RO
rail
s
12
Landing-Tool
  • Problems with lowering gluing tube layers on tube
    layers due to glue viscosity
  • Landing tool pre-aligns chamber and ensures flat
    landing in glue.

BOL
Tower
Effective Easy
s
13