Title: DMC Calibration
1DMC Calibration
Klaus Neumann Product Manager
2DMC - Camera Head Production
3Zeiss Jena Clean Room Facilities
4DMC Calibration - Overview
Platform
Single Head
Radiometry
Online Platform
Geometry
Radiometry
Geometry
PRC PPS S/W Component
DMCORI PPS S/W Component
DMC Post Processing
Ulbricht Sphere
Collimator
homogeneous virtual image radiometry
mosaicking geometric quality assessment
Initial EO for all 8 camera heads
Adjusted, homogeneous pixel sensitivity Color
Balance
Interior Orientation Data
Internal Calibration Data
Calibration CD
5Geometric Calibration
- Designed for DMC
- Rotationtable with 0.3 mgon accuracy
- Circular Targets
- Fully automatic
Zeiss Jena
6Radiometry
- Calibration with Ulbricht Sphere
7DMC Environmental Tests
RTCA / DO 160 E ( ISO 7137) EN
61000-6-22001Electromagnetic compatibility (EMC)
Part 6-4 Generic standards Section 2 Immunity
for industrial environments Section 4 Emission
standard for industrial environments Part 4
Testing and measurement techniques Section 2
Electrostatic discharge immunity test Section 5
Surge immunity test EN550111998 Industrial,
scientific and medical (ISM) radio-frequency
equipment -Radio disturbance characteristics
-Limits and methods of measurement
8DMC Environmental Tests
Vibration -Sinus DO 160 E Section 8
(Vibration) Figure 8-3 Category M (5 -500 Hz)
(Standard Sinusidal Vibration Test curves for
equipment installed in fixed wing aircraft with
reciprocating or turbo propeller engines)
-Random ISO 9022-37 Category 21 (1,4 g rms _at_
20-2000 Hz) Shock 15 g _at_ 11ms according ISO
9022-30 Category 01 Temperature -Temp-Burn In
according own specification Operating
Temperature 0 40C T1 30min T2 4h T3
30min (In minimum 4 cycles) -Storage Temperature
(according own specification)DMC Camera -20C
70C (T1 1h T2 48h T3 1h)All other
Equipment -40C 70C (T1 1h T2 48h T3
1h) Pressure -Under pressure RTCA / DO 160 E
Section 4 (Temperature Altitude)Category C1
10700 m (guaranteed for customers only 8000m)
T0 T1 30min T1T2 0 T2T3 4h Temperature
20C
9Factory Acceptance and Certification
- Factory acceptance Test
- 1st images taken and processed
- Test procedure includes GPS simulated flight
- Test Flight
- Full Mission -gt Test field Elchingen
- 500m flying height
- 5cm GSD
- 8 control points
- AT is run to determine platform calibration
10Standard DIN 18740-4Geometric Calibration
Protocol
- Geometric Calibration Protocol for each camera
module or spectral channel
- For mosaicked images the relative orientation of
the cameras for each exposure
- Alignment of the IMU to the focal plane
?
11(No Transcript)