DMC Calibration
Klaus Neumann Product Manager
2
DMC - Camera Head Production
  • Raw Die
  • DMC Assembly
  • Delivery

3
Zeiss Jena Clean Room Facilities
4
DMC Calibration - Overview
Platform
Single Head
Radiometry
Online Platform
Geometry
Radiometry
Geometry
PRC PPS S/W Component
DMCORI PPS S/W Component
DMC Post Processing
Ulbricht Sphere
Collimator
homogeneous virtual image radiometry
mosaicking geometric quality assessment
Initial EO for all 8 camera heads
Adjusted, homogeneous pixel sensitivity Color
Balance
Interior Orientation Data
Internal Calibration Data
Calibration CD
5
Geometric Calibration
  • Designed for DMC
  • Rotationtable with 0.3 mgon accuracy
  • Circular Targets
  • Fully automatic

Zeiss Jena
6
Radiometry
  • Calibration with Ulbricht Sphere

7
DMC Environmental Tests
RTCA / DO 160 E ( ISO 7137) EN
61000-6-22001Electromagnetic compatibility (EMC)
Part 6-4 Generic standards Section 2 Immunity
for industrial environments Section 4 Emission
standard for industrial environments Part 4
Testing and measurement techniques Section 2
Electrostatic discharge immunity test Section 5
Surge immunity test EN550111998 Industrial,
scientific and medical (ISM) radio-frequency
equipment -Radio disturbance characteristics
-Limits and methods of measurement
8
DMC Environmental Tests
Vibration -Sinus DO 160 E Section 8
(Vibration) Figure 8-3 Category M (5 -500 Hz)
(Standard Sinusidal Vibration Test curves for
equipment installed in fixed wing aircraft with
reciprocating or turbo propeller engines)
-Random ISO 9022-37 Category 21 (1,4 g rms _at_
20-2000 Hz) Shock 15 g _at_ 11ms according ISO
9022-30 Category 01 Temperature -Temp-Burn In
according own specification Operating
Temperature 0 40C T1 30min T2 4h T3
30min (In minimum 4 cycles) -Storage Temperature
(according own specification)DMC Camera -20C
70C (T1 1h T2 48h T3 1h)All other
Equipment -40C 70C (T1 1h T2 48h T3
1h) Pressure -Under pressure RTCA / DO 160 E
Section 4 (Temperature Altitude)Category C1
10700 m (guaranteed for customers only 8000m)
T0 T1 30min T1T2 0 T2T3 4h Temperature
20C
9
Factory Acceptance and Certification
  • Factory acceptance Test
  • 1st images taken and processed
  • Test procedure includes GPS simulated flight
  • Test Flight
  • Full Mission -gt Test field Elchingen
  • 500m flying height
  • 5cm GSD
  • 8 control points
  • AT is run to determine platform calibration

10
Standard DIN 18740-4Geometric Calibration
Protocol
  • Geometric Calibration Protocol for each camera
    module or spectral channel
  • For mosaicked images the relative orientation of
    the cameras for each exposure
  • Alignment of the IMU to the focal plane

?
11