1- The Smartest Line-Interactive UPS with Pure Sine
Wave Output in High Frequency Technology
JPX
2Features
- Microprocessor controlling
- High Frequency Design with High Power Density
- Boost and Buck voltage regulation
- Pure Sine Wave Output
- Selectable output voltage via front panel
- Selectable operating mode via front panel
- Provide Overload, Short-Circuit, Overheat and Fan
fail Protection. - Available to connect external battery cabinet to
extend the backup time - Hot-Swappable / User replaceable battery design
3Features
- Available for various installation environment
with individual UPS EBM case - Output THDlt5 with PFC load under Battery Mode
- Intelligent Slot for SNMP monitoring
- Available for 19 rack installation above 1.5Kva
- Green Power function to save battery energy with
no load - Smart RS232 and USB communication port
- Available to switch on UPS without battery
- EPO switch for operation safety
4Models
- R750/500 Slim Type with 1U High
5Models
- 1500/2000VA 19 Tower-Rack 2-in-1. UPS and EBM
is in different chassis. 2U High.
6Models
- 3000VA 19 Tower-Rack 2-in-1. 2U High.
7Specification
8Specification
9Rear Panel - 750/1Kva
- Input Power Cord
- Outlets
- RS232
- USB
- RJ11/RJ45 connector
T1000
R750
10Rear Panel 1.5/2Kva
UPS
EBM
- Inlet
- External Outlets
- SNMP Slot
- RS232
- USB
- External Battery Connector
- EPO Connector
- RJ11/RJ45
11Rear Panel 3Kva
- Inlet
- Outlets
- SNMP Slot
- RS232
- USB
- Output NFB
- External Battery Connector
- EPO Connector
- RJ11/RJ45
12LED Panel
- ON/OFF Switch
- Self-Test/Silence
- Configuration Key
- Enter Key
- Load Level
- Battery Level
- Fault LED
- Bad Battery LED
- OPV Indicator
- Operating mode indicator
- Line Mode LED
- Battery Mode LED
13Selectable Output Voltage
- The JPX provides the configuration key to let the
user select the suitable output voltage by
himself for 220Vac or 230Vac or 240Vac.
14Selectable Operating Mode
- The JPX also provides the function to let the
user to setup the acceptable operating mode for
its application. - Normal Acceptable AC input voltage for /-20.
- Generator No change to voltage window. However,
the low frequency transfer point is changed to
40Hz and there is no limitation for high
frequency transfer point. - Wide Range The acceptable AC input voltage will
be changed to - -30 20. But the AVR transfer point would be
not changed.
15Comparison Table
Item JPX SGP APC Smart
Intelligent Charging System V V V
Auto-Restart when Power Return V V V
Automatic self-test V V V
AVR Function V V V
Cold-Start V V V
Flexible management Card V V V
Audible Alarm V V V
LED indicators V V V
Remote Management V V V
16Comparison Table
Item JPX SGP APC Smart
RS232/USB Ports V RS232 V
Hot-swappable Battery V V V
Failure Notification V V V
EPO 1.5Kva X 2.2Kva
Adjustable voltage-transfer points V X V
Adjustable voltage sensitivity V X V
Adjustable output voltage V X V
External battery connector 1.5Kva X XL models