AN INTRODUCTION TO THE CIRRUS PRO RANGE OF FIRE DETECTION DETECTORS

presentation player overlay
About This Presentation
Transcript and Presenter's Notes

Title: AN INTRODUCTION TO THE CIRRUS PRO RANGE OF FIRE DETECTION DETECTORS


1
AN INTRODUCTION TO THE CIRRUS PRO RANGE OF FIRE
DETECTION DETECTORS
  • Presented by
  • Chris Malone
  • Export Sales Manager

2
(No Transcript)
3
Contents
  • Different Technologies
  • Understanding Cloud Chamber Detectors
  • Cirrus Pro Series Detector Range
  • Applications
  • Design Concepts
  • Cirrus Pro Sampling Pipe
  • Detector Configurations

Cirrus Pro Series Aspirating Fire Detectors
The worlds most versatile fire detector
4
Aspirating Smoke/Fire DetectorsMain Manufacturers
Vesda - Laser based Optical smoke
detector Stratos - Laser based Optical smoke
detector ICAM Laser Based Optical smoke
detector Wagner Optical based smoke detector
Cirrus Pro Series Aspirating Fire Detectors
Cirrus Pro Cloud Chamber fire detector
The worlds most versatile fire detector
5
Cirrus Pro Series Cloud Chamber Aspirating Fire
Detectors How do they work? What do they detect?
6
Cirrus Pro Series Aspirating Fire Detectors
The worlds most versatile fire detector
7
  • These are sub micron carbon particles
  • They are 0.0025mirco-meters in size
  • They exist in normal air all the time
  • We breath them in continuously
  • In normal conditions only combustion generates
    the massive quantities that the the Cloud
    Chamber can interpret as a fire condition

Cirrus Pro Series Aspirating Fire Detectors
The worlds most versatile fire detector
8
The Cloud Chamber detects this increase in
particle generation
The problem is that these particles are INVISIBLE
9
(No Transcript)
10
Dust particles cannot provide enough cloud
density to cause an alarm from the cloud chamber
11
Cirrus Pro Series Aspirating Fire
Detector Product Range
12
Cirrus Pro 100
  • Unique cloud chamber detection principle
  • Up to 100mtrs - 25mm o/d sampling pipe
  • Single sampling pipe port, single exhaust port
  • Pre-Alarm, Fire 1, Fire 2 Fire 3
    indications
  • Power Healthy and Common Fault indicators
  • Local Buzzer, Silence Reset buttons
  • Vast sensitivity range (incipient - heavy
    polluted)
  • Fixed or Variable sensitivity options
  • Detector text, Alarm text Pipe text
  • 3 Programmable time zones per day
  • Transport Time logging feature
  • Option for Repeat Display Network
    Configuration

13
Cirrus Pro 200
  • Unique cloud chamber detection principle
  • Up to 200mtrs - 25mm o/d sampling pipe
  • Four sampling pipe inlet ports, single exhaust
    port
  • Pre-Alarm, Fire 1, Fire 2 Fire 3
    indications
  • Power Healthy and Common Fault indicators
  • Local Buzzer, Silence Reset buttons
  • Vast sensitivity range (incipient - heavy
    polluted)
  • Fixed or Variable sensitivity options
  • Detector text, Alarm text Pipe text
  • 3 Programmable time zones per day
  • Transport Time logging feature
  • Option for Repeat Display Network
    Configuration

14
Cirrus Pro 200D
  • Unique cloud chamber detection principle
  • Multifunction Display Programmer
  • Up to 200mtrs - 25mm o/d sampling pipe
  • Four sampling pipe inlet ports, single exhaust
    port
  • Pre-Alarm, Fire 1, Fire 2 Fire 3
    indications
  • Power Healthy and Common Fault indicators
  • Local Buzzer, Silence Reset buttons
  • Vast sensitivity range (incipient - heavy
    polluted)
  • Fixed or Variable sensitivity options
  • Detector text, Alarm text Pipe text
  • 3 Programmable time zones per day
  • Transport Time logging feature
  • Option for Repeat Display Network
    Configuration

15
Cirrus Pro 200DSC
  • Unique cloud chamber detection principle
  • Multifunction Display Programmer
  • Up to 200mtrs - 25mm o/d sampling pipe
  • Four sampling pipe inlet ports, single exhaust
    port
  • Pre-Alarm, Fire 1, Fire 2 Fire 3
    indications PER PIPE
  • Power Healthy and Common Fault indicators
  • Local Buzzer, Silence Reset buttons
  • Vast sensitivity range (incipient - heavy
    polluted)
  • Fixed or Variable sensitivity options
  • Detector text, Alarm text Pipe text
  • 3 Programmable time zones per day
  • Transport Time logging feature
  • Option for Repeat Display Network
    Configuration

16
Cirrus Pro 200
  • Unique cloud chamber detection principle
  • In excess of 200mtrs - 25mm o/d sampling pipe
  • (subject to pipe calculation program
    verification)
  • Four sampling pipe inlet ports, single exhaust
    port
  • Pre-Alarm, Fire 1, Fire 2 Fire 3
    indications
  • Power Healthy and Common Fault indicators
  • Local Buzzer, Silence Reset buttons
  • Vast sensitivity range (incipient - heavy
    polluted)
  • Fixed or Variable sensitivity options
  • Detector text, Alarm text Pipe text
  • 3 Programmable time zones per day
  • Transport Time logging feature
  • Option for Repeat Display Network
    Configuration

17
Cirrus Pro 200D
  • Unique cloud chamber detection principle
  • Multifunction Display Programmer
  • In excess of 200mtrs - 25mm o/d sampling pipe
  • (subject to pipe calculation program
    verification)
  • Four sampling pipe inlet ports, single exhaust
    port
  • Pre-Alarm, Fire 1, Fire 2 Fire 3
    indications
  • Power Healthy and Common Fault indicators
  • Local Buzzer, Silence Reset buttons
  • Vast sensitivity range (incipient - heavy
    polluted)
  • Fixed or Variable sensitivity options
  • Detector text, Alarm text Pipe text
  • 3 Programmable time zones per day
  • Transport Time logging feature
  • Option for Repeat Display Network
    Configuration

18
Cirrus Pro 200DSC
  • Unique cloud chamber detection principle
  • Multifunction Display Programmer
  • In excess of 200mtrs - 25mm o/d sampling pipe
  • (subject to pipe calculation program
    verification)
  • Four sampling pipe inlet ports, single exhaust
    pipe port
  • Pre-Alarm, Fire 1, Fire 2 Fire 3
    indications PER PIPE
  • Power Healthy and Common Fault indicators
  • Local Buzzer, Silence Reset buttons
  • Vast sensitivity range (incipient - heavy
    polluted)
  • Fixed or Variable sensitivity options
  • Detector text, Alarm text Pipe text
  • 3 Programmable time zones per day
  • Transport Time logging feature
  • Option for Repeat Display Network
    Configuration

19
Cirrus Pro RDP (Remote Display Programmer)
  • Multifunction Display Programmer
  • May be assigned to individual Cirrus Pro
    detector
  • May be assigned to a network of Cirrus Pro
    detectors
  • Network Status indication
  • Power Healthy and Common Fault indicators
  • Global Network - Silence Reset buttons
  • Local Buzzer with mute facility
  • Remote access/control to any networked Cirrus
    Pro detector
  • Can provide detector text, alarm text pipe
    text per device
  • Can provide Real Time and Historic graph
    data per device

20
Categories
  • High Sensitive Applications
  • General Sensitivity Applications
  • Harsh Environment Applications
  • Special Risk Applications
  • Sensitive Applications

21
High Sensitive applications include.
Data Storage
Control Rooms
Computer Rooms
22
General Sensitive applications include
23
Harsh Environment applications include
Cold Storage
Specialist Production
Food Production
24
Special Risk applications include
Cabinet Protection
Rotunda Areas
Test Rooms
25
Sensitive Applications include
Historic Buildings
High Ceilings
Ornate Ceilings
26
Cirrus Pro Series Aspirating Fire Detectors
The worlds most versatile fire detector
27
  • CIRRUS PRO TCP-IP CONNECTIONS

28
(No Transcript)
29
(No Transcript)
30
Köszönöm THE END
Cirrus Pro Series Aspirating Fire Detectors
The worlds most versatile fire detector
Write a Comment
User Comments (0)
About PowerShow.com