Title: Wet Areas
1Wet Areas
2Definitions BCA Part 3.8.1
Wet Area an are within a building, supplied
with water from a water supply Includes
bathrooms, showers, laundries and sanitary
compartments. Does Not Include Kitchens, bar
area, kitchenettes or domestic food preparation
areas Water Resistant means the property of a
system or material that restricts moisture
movement and will not degrade under conditions of
moisture. Waterproof System Combination of
elements that are required to achieve a
waterproof barrier, may include membrane,
substrate, bond breakers, sealants etc
3Risk Potential For Wet AreasAS 3740
- High Risk Shower Recesses
- Medium Risk Rest of Bathroom Laundry
- Low Risk WC Room immediate area around a
kitchen sink, bar or similar
4AS 3740 High Risk
- Means high probability of damage to structure if
water within high risk area is not contained and
discharged to drainage outlet.
5BCA Requirements High Risk Area
6BCA Requirements High Risk Area
7AS 3740 Medium Risk
- Accidental spillage must be contained to with in
the room. - It is imperative that water not be allowed to
pass into concealed spaces or to adjoining rooms - Drainage not neccessary
8BCA Requirements Medium Risk Area
9BCA Requirements Medium Risk Area
10AS 3740 Low Risk
- Risk of accidental spillage is low requirement to
stop water traversing to adjoining rooms
11BCA Requirements Low Risk
12High Risk Area
13High Risk Area
14Preformed Shower Bases
15Preformed Shower Bases
- Must be fully supported
- Recessed Into Walls
16Preformed Shower Bases
17Bath Installation
18Bath Installation
19Definition
- Hob Upstand at the perimeter to a shower area
20Hob Requirements BCA
21Hob Construction Detail (Internal)
22Hob Construction Detail (External)