Calculation of evaporator surface
3
Problem statement
  • 10,000 lb/hr of distilled water is required from
    untreated water.steam is available at 300oF , and
    the condenser will vent to the atmosphere. How
    much surface is required.?

4
(No Transcript)
5
Assumptions
  • Pressure drop through the condenser and lines of
    about 5psi.
  • The saturation temperature in the evaporator
    shell will be 19.7psia or 226oF.

6
Heat Balance
Q m? H
  • Qevap10,0009619,610,000 Btu/hr
  • Q300oF10,5509109,610,000 Btu/hr

7
(No Transcript)
8
Temperature head
  • ?t 300 226 74oF

9
Overall coefficient
  • From Fig.14.7 at a heat head of 74oF and a vapor
    temperature of 226 oF , the coefficient is 86.5
    of base .
  • Using a base of 700 Btu/(hr)(ft2)
  • UD 7000.865 605

10
(No Transcript)
11
Surface area
  • A Q/(UD)(?t)
  • 9,610,000/(605)(74)
  • 2150 ft2

12
Reference
  • Chapter 14 , D . Q. KERN