Interacciones hiperfinas de impurezas en s - PowerPoint PPT Presentation

About This Presentation
Title:

Interacciones hiperfinas de impurezas en s

Description:

Interacciones hiperfinas de impurezas en s lidos Dr. Alberto F. Pasquevich Departamento de F sica Universidad Nacional de La Plata Estudios de F sica de Estado ... – PowerPoint PPT presentation

Number of Views:72
Avg rating:3.0/5.0
Slides: 37
Provided by: AlbertoPa7
Category:

less

Transcript and Presenter's Notes

Title: Interacciones hiperfinas de impurezas en s


1
Interacciones hiperfinas de impurezas en sólidos
  • Dr. Alberto F. Pasquevich
  • Departamento de Física
  • Universidad Nacional de La Plata

2
Estudios de Física de Estado Sólido mediante
Correlaciones Angulares Perturbadas
  • Dr. Alberto F. Pasquevich
  • Departamento de Física
  • Universidad Nacional de La Plata

3
Alberto F. Pasquevich Departamento de
Física Universidad Nacional de La Plata. La Plata
- Argentina
4
Equipo de Correlaciones Angulares Perturbadas
5
DESCRIPCIÓN NAIVE (SEMI-CLÁSICA) DE LA TÉCNICA PAC
6

DESCRIPCIÓN NAIVE (SEMI-CLÁSICA) DE LA TÉCNICA PAC
7
Las correlaciones angulares direccionales fueron
predichas en el año 1940 por Hamilton y
comprobadas experimentalmente por Brady y Deutsch
en los años 1947-50. La influencia de los campos
extranucleares sobre la correlación angular fue
estudiada por Goertzel en 1946 y la primera
sonda utilizada fue el 111Cd Aeppli, 1951.
8
(No Transcript)
9
Interacción cuadrupolar eléctrica.
10
Tensor Gradiente de Campo Eléctrico
11
I 5/2
? 0
12
(No Transcript)
13
(No Transcript)
14
(No Transcript)
15
Vzz 0
? 0
? 0,3
? 0,7
? 1,0
16
? 0
? 0.05
? 0,10
? 0,15
17
Espectros R(t) de 181Ta en K2ZrF6 tomados con
equipos con diferente resolución temporal a)
CsF ( 0,8 ns) b) NaI(Tl) ( 3 ns)
Martinez, 1981
18
Interacción Magnética
19
(No Transcript)
20
(No Transcript)
21
A comparison between PAC and its sister MS
  • Advantages of PAC,
  • It is insensitive to temperature, in contrast to
    MS, where the recoilless fraction is strongly
    temperature dependent and prevents using MS at
    too high temperatures.
  • The amount of probe nuclei which is needed, is
    orders of magnitude lower than for MS. An
    absolute amount of 1011-1012 PAC probes is
    sufficient. Hence, if the studied nucleus
    represents an impurity in a material, it has
    negligible effect on the matrix.

22
A comparison between PAC and its sister MS
  • Disadvantages,
  • If interactions become too strong, the
    oscillations in R(t) become too fast to detect.
  • If the interaction is too weak, a single
    oscillation takes longer than the time interval
    where enough statistics can be gathered. This
    determines the lower limit of the detectable
    interaction strengths. In MS only such a lower
    limit is present.
  • Another advantage of MS is that it can measure
    the s- electron density in the nucleus by the
    isomer shift, a quantity not probed by PAC.

23
A comparison between PAC and its sister MS
  • Finally, PAC is suited for some nuclei, which are
    inaccessible by MS and vice versa (the most
    common PAC-nuclei are 111Cd parent 111In, 181Ta
    parent 181Hf and 100Pd parent 100Rh).
  • The above aspects of PAC and MS indicate
    complementarily of using the two methods.

24
(No Transcript)
25
(No Transcript)
26
t(ns)
27
(No Transcript)
28
(No Transcript)
29
true stop and start
30
(No Transcript)
31
(No Transcript)
32
(No Transcript)
33
Espectrómetros PAC de 4 Detectores (lógica
slow-fast)
Depto. de Física, La Plata
ISKP, Bonn
34
ISKP, Bonn
35
(2) Separación isotópica
(6)Target
(1) evap. 111InCl3
ISKP, Bonn
36
Instituut voor Kern- en Stralingsfysica
Leuven - Brussels (2003)