PWO/APD/CSP Development at Hiroshima U. - PowerPoint PPT Presentation

1 / 18
About This Presentation
Title:

PWO/APD/CSP Development at Hiroshima U.

Description:

Title: PWO/APD/CSP Development at Hiroshima U. Author: Kenta Shigaki Last modified by: Kenta Shigaki Created Date: 5/27/2004 1:14:32 AM Document presentation format – PowerPoint PPT presentation

Number of Views:99
Avg rating:3.0/5.0
Slides: 19
Provided by: KentaS5
Category:

less

Transcript and Presenter's Notes

Title: PWO/APD/CSP Development at Hiroshima U.


1
PWO/APD/CSP Developmentat Hiroshima U.
  • Hiroshima ALICE-PHOS Group
  • (T.Sugitate, K.Shigaki, et al.)
  • 17 August, 2004, at CERN

2
- Presentation Outline -
  • Recent Activities on PWO/APD/CSP at Hiroshima
    University
  • readout electronics status update
  • CSP design version 3
  • continuing property studies of key components
  • better expertise on PWO/APD handling
  • calorimeter prototype performance evaluation
  • beam tests at KEK-PS and Hiroshima-REFER
  • Summary and Outlook
  • Official Business

3
- Pre-amplifier Design Revised (Ver.3) -
  • slightly modified layout (see next slide)
  • no circuit change from version 2
  • proposed and discussed in July, 2004
  • version 3 status and plan
  • 100 boards in production
  • delivery expected in late-September, 2004
  • 50 of them w/o capacitor C5 mounted
  • to decouple test input pin from signal lines
  • to be sent to Iouri at CERN for evaluation
  • shipping planned in October, 2004

4
- New Pre-amplifier Layout (Ver.3) -
  • version 3 mask (black) overlaid on
    version 2 photo (green)
  • components moved (from yellow to red) to make
    space around APD soldering holes

5
- Pre-amplifier Task and Schedule -
  • early decision of CSP version required
  • version 2 or 3 on 1st PHOS module ?
  • need to complete mass production in JFY04 (ending
    March, 2005)
  • CSP for 1st PHOS module coming soon
  • to be ready for assembly by late-January, 2005

6
- Past PWO Crystal Property Studies -
  • Furukawa Co. Ltd. in Tokyo, Japan

density 8.28 g/cm3 radiation length 0.89
cm Moliere radius 2.2 cm peak emission
420-440 ns refractive index 2.3
Y-doped PbWO4
transmittance measured with Hitachi U3010
spectrophotometer
20 x 20 x 200 mm
ALICE-PHOS operation point
ALICE-PHOS operation point
light yield
mean decay time
7
- Recent PWO Crystal Property Studies -
  • RINC Co. in Minsk, Belarus
  • adopted by CMS
  • investigated similar properties as Furukawas
  • ref. graduation thesis by K.Yokoyama
  • (available only in Japanese)
  • North Crystal Co. in Apatity, Russia
  • adopted by ALICE-PHOS
  • detailed investigation ongoing at Hiroshima
  • further comparison of crystals in progress

8
- Expertise on PWO/APD Handling -
  • cooling with Peltier modules
  • stable operation down to 0 ºC
  • better ground handling to reduce noise
  • successful operation of APD readout system

9
- Prototype Performance Evaluation -
  • prototype components
  • PWO crystals Furukawa (Japan) / RINC (Belarus)
    / North Crystal (Russia)
  • PMT Hamamatsu R1450
  • APD Hamamatsu S8664
  • pre-amplifier Hiroshima ver.1/2
  • cooling Peltier modules
  • tests in Japan
  • Tohoku-LNS (2002) photons at 0.8 1.2 GeV
  • Hiroshima-REFER (2003/04) electrons at 150 MeV
  • KEK-PS (2004) electrons at 0.5 2 GeV

10
- Past Beam Tests at LNS/REFER -
  • w/ PMT readout
  • sE/E 2.5 /?E GeV ? 1.3
  • sx 2.3 mm/?E GeV
  • noise problem with APD at room temp.

counts a.u.
Etotal 141 MeV s/Etotal 7.3 2.8 /?E
total energy MeV
11
- Recent Beam Test at KEK-PS -
  • prototype w/ real ALICE-PHOS components
  • NC PWO Hamamatsu APD
  • electron enriched non-separated (IT) beam
  • negatively charged
  • electron/beam 1 before online enrichment
  • beam momentum scan
  • 0.5 GeV/c 2.0 GeV/c
  • APD HV scan
  • 380 430 V (400 V nominal)

12
- KEK-PS T564 (16-23 June, 2004) -
  • 31.3 M total (mixed) triggers
  • including 664 K electron triggers
  • successful operation of APD readout

13
- PWO/APD/CSP/Readout Signals -
ADC distributions
pre-amplifier output
punch-through hadrons
electrons
shaping amplifier output
14
- Hiroshimas Prototype Performance -
  • sE/E 5.5 at 1 GeV/c, 3.1 at 2 GeV/c
  • with quick and rough near-line calibrations
  • including significant beam momentum spread
  • analysis ongoing to subtract external
    contributions

electrons in center cell selected
gas cherenkov hit required
15
- cf. Kurchatovs Prototype Performance -
  • Kurchatov 16?16 prototype
  • sE/E at 25 ºC
  • 1.3 /E GeV ? 3.6 /?E GeV ? 1.1

16
- Summary and Outlook -
  • charge-sensitive preamplifier (CSP) design
    revised version 3 in test production
  • CSP for 1st PHOS module by January, 2005
  • continuing basic property investigation of PHOS
    key components (PWO/APD/readout)
  • several prototypes fabricated/tested
  • better local expertise
  • independent PHOS prototype performance evaluation
    in progress

17
- Official Business -
  • applied for ALICE associate collaboration
  • together with Tokyo and Tsukuba Universities
  • approval requested at next ALICE meeting
  • official PHOS participation expected soon

18
- PHOS Collaboration at Hiroshima U. -
  • 3 staffs, 10 graduate students
  • H.Harada, K.Haruna, K.Hirashita, K.Homma,
    K.Hosokawa, R.Kohara, Y.Nakamiya, M.Ouchida,
    H.Sakata, K.Shigaki, T.Sugitate, D.Toyoda,
    Y.Tsuchimoto, K.Yokoyama
  • Hiroshima PHOS web page
  • http//www.hepl.hiroshima-u.ac.jp/quark/pwo/
Write a Comment
User Comments (0)
About PowerShow.com