Studies on fast ion distribution - PowerPoint PPT Presentation

1 / 11
About This Presentation
Title:

Studies on fast ion distribution

Description:

Studies on fast ion distribution Correlated with the spectroscopy diagnostics measurements Gerarda Apruzzese http://www.afs.enea.it/apruzzes/ CRE Frascati - ENEA – PowerPoint PPT presentation

Number of Views:49
Avg rating:3.0/5.0
Slides: 12
Provided by: apruz
Category:

less

Transcript and Presenter's Notes

Title: Studies on fast ion distribution


1
Studies on fast ion distribution
  • Correlated with
  • the spectroscopy diagnostics measurements
  • Gerarda Apruzzese
  • http//www.afs.enea.it/apruzzes/
  • CRE Frascati - ENEA
  • Culham, July the 24th

2
Aim of this work
  • Analysis of the positive and negative aspects of
    the diagnostics using the CX spectrum
  • and
  • their possible development at JET

3
Diagnostics compared in the analysis
  • the diagnostic FIDA
  • developed in DIII-D
  • W.W.Heidbrink et al., PPCF 49, (2007)
    1457-1475
  • the fast ion CXRS diagnostic
  • developed in Textor
  • Proceedings of the 17th Topical Conference
    on High-Temperature Plasma Diagnostics,
    Albuquerque, New Mexico, May 2008

4
FIDA Diagnostic( Fast Ion Da Analysis)
  • Measurement of the vertical component of
    perpendicular energy
  • CX emission spectrum of re-neutrals generated by
    beam
  • CX ( beam - plasma ions) fast ions
  • CX ( fast ions beam )
    re-neutrals

5
FIDA measurements in DIII-D
Successful on DIII-D in detecting both NB and
ICRH accelerated D
Y.Luo and W.W. Heidbrink, RSI 78, 033505 (2007)
6
For FIDA success it is necessary
  • Vertical views ( Doppler shift only due to
    gyromotion of fast ions)
  • Good hardware ( f of spectrometer, detector,
    system for avoiding detector saturation)
  • Beam modulation ( for subtracting the background)

7
Complications of FIDA
  • The extracted signal is 10 times less the
    detected signal so
  • GOOD HARDWARE and APPROPRIATE OPTICAL VIEW
    are required
  • Spectral overlap with BES spectrum
  • Intense cold Dalpha light
  • Halo (from CX plasma-beam)

8
The fast ion CXRS diagnostic
  • Using the Fokker-Plank code to simulate the Da
    beam emission spectrum
  • Good results on Textor, where a favourable
    viewing geometry permits to separate the
    contributions due to the fast ions and the beam
    emission spectrum (BES)

9
CX measurements at TEXTOR
spectrum
simulation
Blu wing (slowing down)
Red wing (BES)
10
Situation at JET
  • First and preliminary analysis done by von
    Hellermann and Delabie using the technique of
    fast ion CX diagnostic. Good results.
  • http//users.jet.efda.org/pages/d-task-force/
    meetings/2008/080626/Delabie.ppt
  • FIDA diagnostic requires a vertical viewing line
  • avoiding the divertor region (characterised by
    strong emission) and dedicated equipment.

11
Next step
  • for FIDA firstly, check of vertical view
  • for fast ion CX
  • Prepare future upgrading of spectrometer (Textor
    group)
  • Extend the simulation modelling in order to
    include effects of instabilities on slowing down
    distribution function (Frascati and Textor
    groups)
Write a Comment
User Comments (0)
About PowerShow.com