High Definition Exposure - PowerPoint PPT Presentation

1 / 21
About This Presentation
Title:

High Definition Exposure

Description:

Title: Slide 1 Author: Sir Speedy Last modified by: Marci Hickey Created Date: 9/5/2002 7:02:12 PM Document presentation format: Letter Paper (8.5x11 in) – PowerPoint PPT presentation

Number of Views:38
Avg rating:3.0/5.0
Slides: 22
Provided by: SirSp
Category:

less

Transcript and Presenter's Notes

Title: High Definition Exposure


1
  • High Definition Exposure
  • No Longer for the Little Guy

2
eXact Platemaking
  • Won the 2003 FPPA Technology Innovator Award
  • Tagline Digital Quality at Analog Prices
  • Further development has shown that we also
    improve digital plates
  • Wholeheartedly embracing the inevitable
  • Introducing today another innovation

3
eXact and DigitalA Marriage Made in Heaven
4
Digital Platemaking Today
  • Advancements in ablation
  • Advancements in plate technologies
  • Assume a bump curve is required because of no
    advancements in exposure technology
  • Sacrifices in tonal range due to oxygen depletion

5
Is a Bump Curve Necessary?
  • With banklight exposure it is
  • As the UV is slowly being delivered to the plate,
    oxygen is being depleted thereby shrinking the
    dots
  • What would happen if you could deliver greater
    amounts of UV to the photopolymer in shorter
    periods of time?

6
Cortrons Answer to Digital Exposure
  • Eliminate the need for the bump curve
  • Linear exposure is possible (1-98)
  • Recapture the lost tonal range

7
Introducing
  • eXact Scanning Exposure

8
What is Scanning Exposure?
  • A beam emitting light source that rapidly
    traverses the photopolymer delivering a set
    number of joules
  • Developed in conjunction with some of the top
    trade shops in the US

9
Why Scanning Exposure?
  • Inherent difficulties with bank light systems
  • Point light systems have not been proven for
    larger plate sizes
  • Fixed reflector systems like the eXact 3040 are
    more efficient for smaller formats
  • Easily adapted to other formats

10
How it Has Been Adapted
  • eXact 5280 SE
  • eXact ITR
  • Other formats planned shortly

11
eXact 5280 SE
  • Dual headed, patented liquid cooled light source
  • 16 wide beam of light
  • Chilled bed
  • Digitally integrated
  • Selectable exposure based on plate size
  • Touchscreen operation

12
(No Transcript)
13
(No Transcript)
14
(No Transcript)
15
eXact ITR
  • Up to 90 sleeves
  • Up to 52 repeat
  • Single or double plasma source design
  • Post expose and de-tack option
  • Programmable exposure speeds

16
(No Transcript)
17
(No Transcript)
18
(No Transcript)
19
eXact 3648
  • Development nearly completed
  • Scanning exposure and de-tack
  • Chilled bed
  • Taking orders with deliveries beginning in June

20
Benefits of Scanning Exposure
  • Ability to eliminate the CTP bump curve
  • Recapture the lost tonal range through linear
    exposure
  • Faster exposures
  • Uniform floors
  • Plate-to-plate consistency
  • Less rejects
  • Better quality analog and digital plates
  • Easily adapted to other formats

21
eXact
  • No Longer Just for the Little Guys
Write a Comment
User Comments (0)
About PowerShow.com