Anti-HBc detection in ULTRIO not-repeatable reactive blood donors - PowerPoint PPT Presentation

1 / 9
About This Presentation
Title:

Anti-HBc detection in ULTRIO not-repeatable reactive blood donors

Description:

Anti-HBc detection in ULTRIO not-repeatable reactive blood donors Piotr Grabarczyk, Ewa Brojer Institute of Haematology and Transfusion Medicine, Poland – PowerPoint PPT presentation

Number of Views:38
Avg rating:3.0/5.0
Slides: 10
Provided by: PiotrGra
Learn more at: https://www.nibsc.org
Category:

less

Transcript and Presenter's Notes

Title: Anti-HBc detection in ULTRIO not-repeatable reactive blood donors


1
Anti-HBc detection in ULTRIO not-repeatable
reactive blood donors
  • Piotr Grabarczyk, Ewa Brojer
  • Institute of Haematology and Transfusion
    Medicine, Poland

2
HBV DNA screening in Poland
  • Obligatory HBV DNA screening in all blood donors
    since January 2005
  • PCR Cobas in pools of 24 donations (since 2007 in
    pools of 6)
  • TMA ULTRIO in single donations

3
ULTRIO TMA not-repeatable reactives
  • DEFINITION
  • Triplex ()
  • Discrimination HBV (-) HCV (-) HIV(-)
  • VERIFICATION METHODS
  • alternative NAT tests (Cobas, Arthus)
  • HCV RNA(-), HIV RNA(-) and HBV DNA(-) false
    positive triplex assay
  • HBV DNA positive testing for anti-HBc to
    distinguish occult and window period infection

4
S/co TMA value and anti-HBc detection in samples
reactive in ULTRIO assay(2005)
250 191 donations screened 9 positives
(triplex/dHBV) 129 not-repeatable
S/co of ULTRIOgt10
reactive (0.05)
12 HBV DNA ()
in PCR (10) 5/9 (56) anti HBc
positive
S/co of ULTRIOgt10

10/12 (83,3) anti-HBc positive
5
Aim of the study (2006)
  • Analysis of S/Co distribution in samples with not
    -repeatable results of ULTRIO TMA
  • Assessment of anti-HBc frequency in all samples
    with not-repeatable results in ULTRIO TMA

6
HBV DNA screening yield in 2006
  • 247 263 donations
  • 1 positive
    366 not-repeatable
    reactive (0,14)
  • 3 (0,8)HBV DNA positive 363
    negative in
  • in PCR
    PCR

S/co of TMAgt10
7
S/co of ULTRIO test in 363 HBV DNA negative
not-repeatable samples
S/co
8
Anti-HBc frequency in HBV DNA negative samples
with not-repeatable results of ULTRIO test
dependence on S/co value
Anti-HBc frequency in donors negative in TMA
assay 7
ULTRIO S/co value
9
Instead of conclusions
  • Are the anti-HBc positive donors with
    not-repeatable ULTRIO results infected with
    occult HBV with virus load below sensitivity of
    the assay?
  • What is the clinical significance of such
    infections?
  • Can anti-HBc testing be useful in confirmatory
    procedure?
Write a Comment
User Comments (0)
About PowerShow.com