Title: Legacy Adaptor (KX-NS8290) Test Environments Setup Manual


1
Legacy Adaptor (KX-NS8290) Test Environments
Setup Manual
1. Example of test configuration -gt Please
refer to page. 2. NS1000
setup procedure -gt Please refer to
page. (1) KX-NS1000 (Ver
002.xxxx) Setup Procedure (2) KX-NS1000 (Ver
001.xxxx) Setup Procedure 3. Legacy
Adaptor setup procedure -gt Please refer to
page. (1)Initial
Configuration (2)Setting for the test
configuration 4. Legacy Adopter Log capture
manual -gt Please refer to
page.
TEST Config
NS1000 SETUP
NS8290 SETUP
Log Capture
2
TEST Config
Legacy Adaptor (KX-NS8290)
PRI30 Line Status
System Status
SPEED
PRI30
LINK/ACT
Initial SW
VoIP LAN
AC-Adaptor
3
TEST Config
Example of test configuration
PRI Network
According to the your test environment,
please set a fixed IP address for the NS8290
and NS1000.
Legacy Adaptor
IP192.168.0.151 (default)
AC-Adaptor
Ether
Fast Ether (100M) L2SW with or without PoE
Ether
Ether
PC for Web-MC
Not use PRI23 port
Analog TEL(2W)
KX-NS1000
IP192.168.0.101 (default)
IP-PT
4
TEST Config
Legacy Adaptor Test Logical Channel Connection
Legacy Adaptor
KX-NS1000
SIP Server
SIP Trunk
SIP ID 401
SLT I/F
SIP-Trunk I/F 01
SIP ID 402
PRI Network
SIP-Trunk I/F 02
ex101
SIP ID 403
SIP-Trunk I/F 03
PR I/F


IP-PT I/F
SIP ID 423
SIP-Trunk I/F 23
or
or
SIP ID 430
ex103
SIP-Trunk I/F 30
5
NS1000 SETUP
KX-NS1000 (Ver 002.xxxx) Setup Procedure (1/7)
1)Select Virtual
2)Select V-SIPGW16
3)Set Total number of cards as 2.
4)Set to the OUS state for each slot.
6
NS1000 SETUP
KX-NS1000 (Ver 002.xxxx) Setup Procedure (2/7)
1)Select Port Propertty
7
NS1000 SETUP
KX-NS1000 (Ver 002.xxxx) Setup Procedure (3/7)
1)Select Trunk Adopyer
8
NS1000 SETUP
KX-NS1000 (Ver 002.xxxx) Setup Procedure (4/7)
1)Set the Trunk Adaptor IP address of port1
2)Push Apply button
3)Push Next button
9
NS1000 SETUP
KX-NS1000 (Ver 002.xxxx) Setup Procedure (5/7)
1)Push Finish button
10
NS1000 SETUP
KX-NS1000 (Ver 002.xxxx) Setup Procedure (6/7)
1) check that the setting of IP address are
reflected in each port
11
NS1000 SETUP
KX-NS1000 (Ver 002.xxxx) Setup Procedure (7/7)
1)Set to the INS state for each slot.
12
NS1000 SETUP
KX-NS1000 (Ver 001.xxxx) Setup Procedure (1/6)
1)Push Virtual button
NOTE In case of PBX Version of NS1000 is Ver
001.xxxx, must be installed in advance 16ch
IP-TRUNK license key X 2 licences.
13
NS1000 SETUP
KX-NS1000 (Ver 001.xxxx) Setup Procedure (2/6)
1)Select V-SIPGW16 tab
2)Set Total number of cards as 2.
14
NS1000 SETUP
KX-NS1000 (Ver 001.xxxx) Setup Procedure (3/6)
1)Set to the OUS state for each slot.
15
NS1000 SETUP
KX-NS1000 (Ver 001.xxxx) Setup Procedure (4/6)
1)Select Port Property menu
16
NS1000 SETUP
KX-NS1000 (Ver 001.xxxx) Setup Procedure (5/6)
Please set the parameters of the port properties
as follows.In case of parameters except User
Name and Authentication ID can be set all
ports by using COPY function. In case of User
Name and Authentication ID, please configure
each port
No Slot Port Main Main Account Account Account Register
No Slot Port Channel Attribute SIP Server IP Address User Name Authenti -cation ID Authenti -cation Pass Register Server IP Address
1 31 1 Basic Channel 192.168.0.151 401 401 1234 192.168.0.151
2 31 2 ? ? 402 402 ? ?
3 31 3 ? ? 403 403 ? ?
4 31 4 ? ? 404 404 ? ?
31 ? ? ? ?
13 31 13 ? ? 413 413 ? ?
14 31 14 ? ? 414 414 ? ?
15 31 15 ? ? 415 415 ? ?
16 31 16 ? ? 416 416 ? ?
17 32 1 ? ? 417 417 ? ?
18 32 2 ? ? 418 418 ? ?
19 32 3 ? ? 419 419 ? ?
20 32 4 ? ? 420 420 ? ?
32 ? ? ? ?
29 32 13 ? ? 429 429 ? ?
17
NS1000 SETUP
KX-NS1000 (Ver 001.xxxx) Setup Procedure (6/6)
Activate the virtual card to push the INS
button for each slot..
18
NS8290 SETUP
Initial Configuration (1/7)
Username ? INSTALLER Password ? 1234
http//192.168.0.151/WebMC/users/login
19
NS8290 SETUP
Initial Configuration (2/7)
1)Push Install button
20
NS8290 SETUP
Initial Configuration (3/7)
1)Push Next button
21
NS8290CE SETUP
Initial Configuration (4/7)
1)Push next button
22
NS8290 SETUP
Initial Configuration (5/7)
1)According to the your test environment,
set a fixed IP address
1)Push next button
23
NS8290 SETUP
Initial Configuration (6/7)
1)Push next button
24
NS8290 SETUP
Initial Configuration (7/7)
1)Please set KX-NS8290CE password
2)Push next button
25
NS8290 SETUP
Setting for the test configuration (1/9)
1)After all the initialization procedure
finished, KX-NS8290CE will display this home
menu. 2)Please push this icon, and enter the
path configuration menu.
26
NS8290 SETUP
Setting for the test configuration (2/9)
2)Push OUS button
1)Enter the SIP card property menu by select
the 2.SIP Card Property
27
NS8290 SETUP
Setting for the test configuration (3/9)
1) Set with reference to the note below
2)Push Apply
NOTE If the PBX Version of NS1000 is Ver
001.xxxx, please set the Activation Key Mode as
"YES". In that case, Authentication ID setting of
"SIP port Property" shown in the following pages,
is required. Otherwise, the settings that are
shown in this and subsequent pages is not
required.
28
NS8290 SETUP
Setting for the test configuration (4/9)
1)Enter the SIP port property menu by select
the 3.SIP Port Property
29
NS8290 SETUP
Setting for the test configuration (5/9)
1)Set the Authntication Password of port1
as 1234.
2)Push the Copy button
30
NS8290 SETUP
Setting for the test configuration (6/9)
1) Click here
2)Select the port number, from port2
until port30
3) Push Copy button
31
NS8290 SETUP
Setting for the test configuration (7/9)
1)Enter the SIP card property menu by select
the 2.SIP Card Property
32
NS8290 SETUP
Setting for the test configuration (8/9)
1)Push INS button
33
NS8290 SETUP
Setting for the test configuration (9/9)
1)After all the settings has been completed,
please save the system data
2) When you close the Web maintenance
console, please press the LOGOUT button
34
Log Capture
Legacy Adaptor Error Log Capture
2) Push Minor Button
1) Utility -gt 3.Log -gt 1.Error Log
3) Push Save Button to store data to PC
35
Log Capture
Legacy Adaptor Syslog Capture
1) Utility -gt 3.Log -gt 2. Syslog
2) Push Save Button to store data to PC
36
Log Capture
Legacy Adaptor ISDN/QSIG Protocol Trace Capture
3) Push Start Button
2) Select Accumulation Trace
4) Push Capture Button to store data to PC
1) Utility -gt 4.Monitor/Trace -gt 1.ISDN/QSIG
Protocol Trace
Write a Comment