Title: The VIMOS IFU Pipeline


1
The VIMOS IFU Pipeline
  • Carlo Izzo

2
The VIMOS IFU
3
The VIMOS IFU
HR and MR mode
LR mode
4
The VIMOS IFU
5
Flat fields
6
IFU pipeline - historical background
  • The IFU pipeline was delivered by the VIRMOS
    Consortium on June 2003. No documentation was
    available, and only LR spectral observations were
    supported at the time. The IFU DRS was also
    declared not to be suitable for automatic data
    reduction.
  • On July 2003 it was decided to rewrite the IFU
    pipeline from scratch. Valuable suggestions about
    IFU data reduction issues were provided by Eric
    Emsellem and Arlette Rousset-Pecontal (Centre de
    Recherche Astronomique de Lyon), and by Martin
    Roth (Astro-physikalisches Institut Potsdam).
  • The new ESO VIMOS pipeline, based on the CPL, was
    designed and developed in about eight months. It
    was delivered to Paranal on March 2004, and to
    the user community on July 2004.

7
VIMOS IFU pipeline recipes
  • vmifucalib
  • Input a sequence of flat field and one arc lamp
    exposures.
  • Produces the extraction mask (spectral tracing
    wavelength calibration), and the relative
    transmission correction.
  • vmifuscience
  • Input scientific exposure, extraction mask, and
    relative transmission correction. Optionally, a
    spectral response curve.
  • Produces the extracted, wavelength calibrated,
    transmission corrected spectra, and a
    reconstructed image of the field-of-view.
    Optionally, a relative flux correction can be
    applied.
  • vmifustandard
  • Analogous to vmifuscience, it produces also a
    spectral response curve.

8
vmifucalib
_________________________________
9
vmifucalib
10
vmifuscience
11
vmifucalib
Extracted scientific spectra
Reconstructed FOV image
12
Spectral extraction
13
Fiber profile
14
Fiber profile
(pixel)
15
Problems
  • Instrument instability ruins the scientific
    reduction online, and enforces the acquisition of
    night calibrations
  • Contamination between multiplexed spectra may
    occasionally prevent an accurate tracing and a
    correct fiber identification
  • The extraction mask cannot be aligned to a dark
    scientific exposure

16
It would be nice
  • WCS on reconstructed images of the field-of-view
  • Alignment and sum of jittered exposures
  • Optimal extraction
  • More interactivity

17
THE END