LHCb VErtex LOcator - PowerPoint PPT Presentation

About This Presentation
Title:

LHCb VErtex LOcator

Description:

LHCb VErtex LOcator For precision measurements of CP-violation at CERN (GENEVE) HALF of DETECTOR Secondary vacuum container Si strip detector Vacuum vessel – PowerPoint PPT presentation

Number of Views:85
Avg rating:3.0/5.0
Slides: 2
Provided by: marc4179
Category:
Tags: comic | lhcb | locator | strip | vertex

less

Transcript and Presenter's Notes

Title: LHCb VErtex LOcator


1
LHCb VErtex LOcator For precision measurements of
CP-violation at CERN (GENEVE)
HALF of DETECTOR
Secondary vacuum container
Vacuum vessel
Exit foil
Vacuum pump
Prototype foil of the Secondary vacuum container
SILICON MODULE
PROJECT DESCRIPTION Design and production of the
Silicon VErtex LOcator for the LHCb experiment at
CERN. During collisions of the two proton beams
in the 'Large Hadron Collider' (LHC) B-mesons
will be produced. The decay of these B-mesons is
not invariant under Charge and Parity reversal
they show CP-violation. The B-mesons travel about
7 mm before decaying into other particles. The
micro vertex has been designed to do an accurate
measurement of the decay position (vertex) of
these B-mesons. The VErtex LOcator consists of
a row of silicon detectors, each 0.3 mm thick.
Charged particles that traverse the silicons
generate an electrical charge which can be
measured. The silicons are positioned
perpendicular to the proton beam at a radial
distance of 8 mm from the beam. To be close to
the proton proton interaction and with a minimum
amount of material in front, the sensors have to
be placed in a secondary vacuum box During the
filling and ramping of the LHC ring the detectors
have to moved out by 30 mm in order to prevent
radiation damage. For the actual measurements
they have to be moved in again with a position
accuracy of 0.05 mm. The whole VErtex LOcator is
placed inside the vacuum system. The detectors
and the read-out electronics are constructed from
radiation hard components. The heat produced by
the electronics is taken care of by a cooling
system that uses CO2 as refrigerant. The signals
from the detector are transported outside the
vacuum system for further analysis through 22,000
signal cables. PROJECT GROUPS NIKHEF, VU (The
Netherlands), Liverpool University (UK), CERN,
Lausanne University (Switzerland), ASIC lab.
University Heidelberg (Germany)
LHC-b detector
VErtex LOcator
VErtex LOcator
www.nikhef.nl/pub/experiments/bfys/lhcb/vertex/
Write a Comment
User Comments (0)
About PowerShow.com