Title: Sales Opportunities


1
Sales Opportunities
VersiStart i II
2
VersiStart i II Range
  • Ranges
  • 23 Models
  • 18A 200A
  • 7.5kW 220kW _at_ 400VAC
  • Voltage Ranges
  • 200 440VAC
  • 200 575VAC
  • Protection
  • IP20 18 100 A 140 200 A (when
    installed with optional finger
    guards)
  • IP00 140 200 A
  • Certification

3
VersiStart i II Highlights
  • Easy and economic to install
  • Soft start/stop plus motor/system protection
  • Fast and easy to configure
  • Compact design minimises panel space
  • Integrated bypass
  • Relay outputs to assist system integration
  • Offers the most popular soft start and soft stop
    methods
  • Essential motor and system protection
  • Built-in thermal model
  • Balanced Vector Control
  • Serial Communication Modules Modbus, DeviceNet,
    Profibus, USB

4
Industry Types
Water Supply Local government, water utilities etc
Water Treatment Local government, waste water
sewage utilities etc
Irrigation
Food Beverage Slaughter houses, frozen foods,
cool stores, beverage manufacturers etc
Forestry Saw Mills, Pulp Paper Processors etc
Quarries Mining
HVAC Building Services
Petrochemical Production
Marine
Generator Set Supplies
5
Water Supply
Pumps
6
Water Treatment
Pumps
Aerators
Milliscreens
7
Irrigation
Pumps
8
Food and Beverage
Pumps
Compressors
Conveyors
Fans
9
Forestry
Slabber
Chippers
Edgers
Debarkers
Hydraulic Power Packs
Fans
Refiners
Pumps
10
Quarrying and Mining
Crushers
Conveyors
Screens
Fans
Pumps
11
HVAC Building Services
Chiller Compressors
Fans
Pumps
12
Petrochemical Production
Compressors
Fans
Pumps
13
Marine
Winches
Compressors
Fans
Pumps
14
Generator Set Supplies
Large Machines run off Limited Supplies
15
Soft Start Benefits for Pumps
  • Gentle Acceleration
  • Minimises pressure surges during start thus
    preventing mechanical damage to pipes, valves,
    transducers, etc.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply.
    This is very important where large pumps are
    installed in residential areas.
  • Limits demand on the supply. This can reduce
    reticulation costs when supplying power to large
    pumps installed in remote areas, e.g. farm
    irrigation pumps.
  • Related VS i II Functions Current Limit ,Current
    Ramp

16
Soft Start Benefits for Pumps
  • Soft Stop
  • Timed Voltage Ramp extends and control the pump
    stopping, eliminating the damaging effects of
    fluid hammer often associated with uncontrolled
    pump stopping.
  • This will reduce the need for regular
    maintenance/repair and extend the life of pumps,
    valves, pipes, transducers, etc.
  • New installation costs can be reduced because the
    system design need not allow for repetitive high
    pressure surges. For example, pressure surge
    tanks and motorised valves become unneccessary
    and the specification of pipes, valves,
    transducers, etc, can be reduced.
  • Related VS i II Function Soft Stop Time

17
Soft Start Benefits for Pumps
  • Motor Overload Protection - Dual Thermal Model
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • In the petrochemical industry this feature can be
    vital for safety. If excessive motor temperature
    goes undetected, a hazardous situation exists.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

18
Soft Start Benefits for Pumps
  • Phase Sequence Protection
  • The sequence of the incoming three phase supply
    is monitored. If a change is detected, the VS i
    II will prevent a start.
  • This is important in applications where damage
    can occur if the pump runs in reverse direction.
  • Related VS i II Function Phase Sequence
    Protection

19
Soft Start Benefits for Pumps
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor in the
    event of a jammed or stalled pump.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that set for the
    instantaneous overload protection, the VS i II
    will immediately trip.
  • This will prevent damage to the motor, pump and
    couplings caused by abnormally large solids
    jamming the pump, eg tree debris in a flood pump
    or large rocks in a slurry pump.
  • Related VS i II Function Fixed at 600 of Motor
    FLC

20
Soft Start Benefits for Compressor Chillers
  • Gentle Acceleration
  • Minimises torque transients during start thus
    preventing mechanical damage to couplings, belts,
    bearings and the compressor.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply.
  • Related VS i II Functions Current Limit,
    Current Ramp
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Related VS i II Function Motor Trip Class

21
Soft Start Benefits for Compressor Chillers
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals
  • Phase Sequence Protection
  • The rotation of the incoming three phase supply
    is monitored. If a change is detected, the VS i
    II will prevent a start.
  • This is important in applications where damage
    can occur if the compressor runs in reverse
    direction.
  • Related VS i II Function Phase Sequence
    Protection

22
Soft Start Benefits for Compressor Chillers
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor in the
    event of a jammed or stalled compressor.
  • It can also detect failure of the Off Loader
    device.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the Instantaneous
    overload protection, the VS i II will immediately
    trip.
  • This will prevent damage to the motor, compressor
    and couplings caused by a lock up situation. eg
    liquid ammonia entering the compressor.
  • Related VS i II Function Fixed at 600 of Motor
    FLC

23
Soft Start Benefits for Fans
  • Gentle Acceleration
  • Minimises torque transients during start thus
    preventing mechanical damage to couplings, belts
    and bearings.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Related VS i II Function Motor Trip Class

24
Soft Start Benefits for Fans
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals
  • Phase Sequence Protection
  • The rotation of the incoming three phase supply
    is monitored. If a change is detected, the VS i
    II will prevent a start.
  • This is important in applications where damage
    may occur if the fan runs in reverse direction.
  • Related VS i II Function Phase Sequence
    Protection

25
Soft Start Benefits for Fans
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor in the
    event of a jammed or stalled fan.
  • Can give early indication of bearing failure.
  • Related VS i II Function Excess Start Time
  • Fan Load Monitoring
  • Via an optional remote operator a 4-20mA analogue
    output can be used to monitor the fan loading.
    This allows the VS i II to be directly interfaced
    with a building management system without the
    need for extra equipment.
  • Related VS i II Function 4-20mA Output (Motor
    Current)

26
Soft Start Benefits for Conveyors
  • Gentle Acceleration
  • Minimises torque transients and extends starting
    time for gentle run up of the conveyor.
  • Reduces the risk of product damage caused by
    jerky starts.
  • Provides optimimum conveyor starting regardless
    of product loading, i.e. loaded/unloaded.
  • Prevents mechanical damage to couplings, belts
    and bearings.
  • Prevents conveyor belt slap during start.
  • Reduces stress on counter balances and weights.
  • Related VS i II Functions Current Limit, Current
    Ramp

27
Soft Start Benefits for Conveyors
  • Minimum start current
  • Reduces electrical disturbance on the supply.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Soft Stop
  • Extends conveyor stopping time thus reducing the
    risk of product damage caused by sudden stops.
  • Related VS i II Functions Soft Stop Time
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Related VS i II Function Motor Trip Class

28
Soft Start Benefits for Conveyors
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals
  • Phase Sequence Protection
  • The rotation of the incoming three phase supply
    is monitored. If a change is detected, the VS i
    II will prevent a start.
  • This is important in applications where damage
    can occur if the conveyor runs in reverse
    direction.
  • Related VS i II Function Phase Sequence
    Protection

29
Soft Start Benefits for Conveyors
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor caused by a
    jammed or excessively overloaded conveyor during
    start up.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will immediately
    trip.
  • This will prevent damage to the motor, conveyor
    and couplings caused by severe product overload
    or a stalled conveyor .
  • Related VS i II Function Fixed at 600 of Motor
    FLC

30
Soft Start Benefits for Crushers
  • Gentle Acceleration
  • Minimises torque transients for gentle crusher
    starting thus extending coupling, belt and
    bearing life.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply.
  • Limits the demand on the supply. This is
    important in remote sites where generator sets
    are used for reticulation.
  • Related VS i II Functions Current Limit, Current
    Ramp

31
Soft Start Benefits for Crushers
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Maximises product throughput by allowing the
    motor to operate at its upper thermal limit.
  • Provides reliable motor protection while allowing
    the crusher to ride through temporary product
    overload situations.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

32
Soft Start Benefits for Crushers
  • Phase Sequence Protection
  • The rotation of the incoming three phase supply
    is monitored. If a change is detected, the VS i
    II will prevent a start.
  • This is important in applications where damage
    can occur if the crusher runs in reverse
    direction.
  • Related VS i II Function Phase Sequence
    Protection
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor caused by a
    jammed or excessively overloaded crusher during
    start up.
  • Related VS i II Function Excess Start Time

33
Soft Start Benefits for Crushers
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will immediately
    trip.
  • This will prevent damage to the motor, crusher
    and couplings caused by severe product overload
    or a stalled crusher while running, eg, oversized
    rock jammed in crusher rollers.
  • Related VS i II Function Fixed at 600 of Motor
    FLC
  • Crusher Load Monitoring and Control
  • Via an optional remote operator a 4-20mA analogue
    output can be used to monitor the crusher
    loading. This allows the VS i II to be directly
    interfaced with the infeed conveyor control
    system to maximise product throughput.
  • Related VS i II Function 4-20mA Output (Motor
    Current)

34
Soft Start Benefits for Generator Sets
  • Optimum Starting Performance
  • The VS i II will optimise the starting
    performance of any motor supplied by a generator
    set.
  • Start current is minimised reducing the kVA
    demand on the alternator and the kW demand on the
    primemover.
  • Load is gradually applied to the alternator. This
    will assist in maintaining a constant voltage and
    frequency during start providing a more overall
    stable system.
  • New motors may be used on existing generator sets
    already operating at near full capacity.
  • Possibility of reduced generator set sizing on
    new installations where motors are a signicant
    part of the load.
  • Related VS i II Functions Current Limit, Current
    Ramp

35
Soft Start Benefits for Generator Sets
  • Frequency Protection
  • The VS i II monitors the supply frequency and can
    be set to trip if it falls outside the protection
    tolerance. This is useful on generator set
    applications for detecting under and over
    frequency situations. The allowable frequency
    tolerance is greater during start enabling the
    generator set to ride through the motor starting
    conditions.
  • Related VS i II Function 40Hz lt Operating Range
    lt 72Hz
  • Phase Loss Protection
  • Motor line currents are monitored and if a
    programmed imbalance is detected the VS i II will
    trip. This is useful for detecting a problem in
    the alternator section of the generator set.
  • Related VS i II Function Highest and lowest
    currents on the three phases vary by an average
    of 30 for more than 3 seconds.

36
Soft Start Benefits for Generator Sets
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will immediately
    trip.
  • Severe overload situations can cause the
    generator set to become unstable and run below
    its safe operating speed. This can be avoided
    using the instantaneous overload protection
    function.
  • Related VS i II Function Fixed at 600 of Motor
    FLC

37
Soft Start Benefits for Chippers
  • Gentle Acceleration
  • Minimises torque transients for a gentle run up
    of the chipper. This reduces mechanical stress on
    couplings, belts and knife blades thus lowering
    maintenance costs.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply by
    minimising the required start current. This is
    important at remote sites where supply is
    limited.
  • Related VS i II Functions Current Limit, Current
    Ramp.

38
Soft Start Benefits for Chippers
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Maximum product throughput can be achieved
    without the risk of motor failure.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

39
Soft Start Benefits for Chippers
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor and knife
    blades caused by a jammed or excessively
    overloaded chipper during start up.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will immediately
    trip.
  • Lock up situations are common in chipper
    applications. Instantaneous overload protection
    will reduce the risk of knifeblade damage due to
    torque shocks experienced under these conditions
  • Related VS i II Function Fixed at 600 of Motor
    FLC

40
Soft Start Benefits for Chippers
  • Chipper Load Monitoring and Control
  • Via an optional remote operator a 4-20mA analogue
    output signal can be used to monitor chipper
    loading and can be interfaced with the infeed
    conveyor control system to maximise product
    throughput.
  • Related VS i II Function 4-20mA Output (Motor
    Current)

41
Soft Start Benefits for Aerators
  • Gentle Acceleration
  • Increases mechanical stability during start up to
    reduce risk of tipping.
  • Minimises torque transients during start thus
    preventing mechanical damage to couplings and
    bearings.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply.
  • Related VS i II Functions Current Limit, Current
    Ramp

42
Soft Start Benefits for Aerators
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

43
Soft Start Benefits for Aerators
  • Phase Sequence Protection
  • The rotation of the incoming three phase supply
    is monitored. If a change is detected, the VS i
    II will prevent a start.
  • This is important in applications where damage
    can occur if the aerator runs in reverse
    direction.
  • Related VS i II Function Phase Sequence
    Protection

44
Soft Start Benefits for Milliscreens
  • Gentle Acceleration
  • Milliscreens commonly use small motors with
    gearboxes to produce high output torque. The VS i
    II will reduce mechanical stress on gearboxes,
    couplings, belts and bearings.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Motor Overload Protection
  • The VS i II mathematically calculates the motor
    windings and body temperature allowing for safe
    use of the motors thermal capacity.
  • Related VS i II Function Motor Trip Class

45
Soft Start Benefits for Milliscreens
  • Phase Sequence Protection
  • The rotation of the incoming three phase supply
    is monitored. If a change is detected, the VS i
    II will prevent a start.
  • This is important as damage can occur to the
    gearbox and milliscreen if run in reverse
    direction.
  • Related VS i II Function Phase Sequence
    Protection
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor caused by a
    seized gearbox, couplings, belts and bearings
    during start up.
  • Related VS i II Function Excess Start Time

46
Soft Start Benefits for Slabbers
  • Gentle Acceleration
  • Minimises torque transients for a gentle run up
    of the slabber. This reduces mechanical stress on
    couplings and saw blades extending equipment life
    and lowering maintenance costs.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply by
    minimising the required start current. This is
    important at remote sites where supply is
    limited.
  • Related VS i II Functions Current Limit, Current
    Ramp

47
Soft Start Benefits for Slabbers
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Maximum product throughput can be achieved
    without the risk of motor failure.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

48
Soft Start Benefits for Slabbers
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor and saw
    blades caused by a jammed or excessively
    overloaded slabber during start up.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will immediately
    trip.
  • Lock up situations are common in slabber
    applications. Instantaneous overload protection
    will reduce the risk of sawblade damage due to
    torque shocks experienced under these conditions
  • Related VS i II Function Fixed at 600 of Motor
    FLC

49
Soft Start Benefits for Slabbers
  • Slabber Load Monitoring and Control
  • Via an optional remote operator a 4-20mA analogue
    output signal can be used to monitor slabber
    loading and can be interfaced with the infeed
    conveyor control system to maximise product
    throughput.
  • Related VS i II Function 4-20mA Output (Motor
    Current)

50
Soft Start Benefits for Edgers Arbors
  • Gentle Acceleration
  • Minimises torque transients for a gentle run up
    of the edger.
  • Reduces mechanical stress on couplings and saw
    blades extending equipment life and lowering
    maintenance costs.
  • Prevents sawblade de-alignment.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply by
    minimising the required start current. This is
    important at remote sites where supply is
    limited.
  • Related VS i II Functions Current Limit, Current
    Ramp

51
Soft Start Benefits for Edgers Arbors
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Motor thermal model will provide optimum
    protection without nuisance tripping.
  • Maximum product throughput can be achieved
    without the risk of motor failure.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

52
Soft Start Benefits for Edgers Arbors
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor and saw
    blades caused by a jammed or excessively
    overloaded edger during start up.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will
    immediately trip.
  • Jamming is common in edger applications.
    Instantaneous overload protection will reduce the
    risk of sawblade damage and de-alignment under
    these conditions.
  • Related VS i II Function Fixed at 600 of Motor
    FLC

53
Soft Start Benefits for Edgers Arbors
  • Edger Load Monitoring and Control
  • Via an optional remote operator a 4-20mA analogue
    output signal can be used to monitor edger
    loading and can be interfaced with the infeed
    conveyor control system to maximise product
    throughput.
  • Related VS i II Function 4-20mA Output (Motor
    Current)

54
Soft Start Benefits for Debarkers
  • Gentle Acceleration
  • Minimises torque transients for a gentle run up
    of the debarker.
  • Reduces mechanical stress on couplings and saw
    blades extending equipment life and lowering
    maintenance costs.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply by
    minimising the required start current. This is
    important at remote sites where supply is
    limited.
  • Related VS i II Functions Current Limit, Current
    Ramp

55
Soft Start Benefits for Debarkers
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Motor thermal model will provide optimum
    protection without nusiance tripping.
  • Maximum product throughput can be achieved
    without the risk of motor failure.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

56
Soft Start Benefits for Debarkers
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor, ring gear
    and saw blades caused by a jammed or excessively
    overloaded debarker during start up.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will
    immediately trip.
  • In the case of a jammed log, instantaneous
    overload protection will reduce the risk of ring
    gear and saw blade damage.
  • Related VS i II Function Fixed at 600 of Motor
    FLC

57
Soft Start Benefits for Debarkers
  • Debarker Load Monitoring and Control
  • Via an optional remote operator a 4-20mA analogue
    output signal can be used to monitor edger
    loading and can be interfaced with the infeed
    conveyor control system to maximise product
    throughput.
  • Related VS i II Function 4-20mA Output (Motor
    Current)

58
Soft Start Benefits for Hydraulic Power Packs
  • Gentle Acceleration
  • Hydraulic Power Packs are commonly used to power
    conveyor systems which feed logs through process
    machinery. Torque transients are minimised for a
    gentle run up.
  • Reduces mechanical stress on fluid couplings and
    other moving parts extending equipment life and
    lowering maintenance costs.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply by
    minimising the required start current. This is
    important at remote sites where supply is
    limited.
  • Related VS i II Functions Current Limit, Current
    Ramp

59
Soft Start Benefits for Hydraulic Power Packs
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Maximum product throughput can be achieved
    without the risk of motor failure.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

60
Soft Start Benefits for Hydraulic Power Packs
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor and other
    moving equipment caused by a jammed log in the
    process line during start up.
  • Related VS i II Function Excess Start Time

61
Soft Start Benefits for Refiners
  • Gentle Acceleration
  • Minimises torque transients for a gentle run up
    of the refiner. This reduces mechanical stress on
    couplings, belts and knife blades thus lowering
    maintenance costs.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply by
    minimising the required start current. This is
    important at remote sites where supply is
    limited.
  • Related VS i II Functions Current Limit, Current
    Ramp

62
Soft Start Benefits for Refiners
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Maximum product throughput can be achieved
    without the risk of motor failure.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

63
Soft Start Benefits for Refiners
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor and knife
    blades caused by a jammed or excessively
    overloaded refiner during start up.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will immediately
    trip.
  • Lock up situations are common in refiner
    applications. Instantaneous overload protection
    will reduce the risk of knifeblade damage due to
    torque shocks experienced under these conditions.
  • Related VS i II Function Fixed at 600 of Motor
    FLC

64
Soft Start Benefits for Refiners
  • Refiner Load Monitoring and Control
  • Via an optional remote operator a 4-20mA analogue
    output signal can be used to monitor edger
    loading and can be interfaced with the infeed
    conveyor control system to maximise product
    throughput.
  • Related VS i II Function 4-20mA Output (Motor
    Current)

65
Soft Start Benefits for Winches
  • Gentle Acceleration
  • Minimises torque transients for gentle winch
    starting thus extending coupling, winch line and
    bearing life.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply.
  • Limits the demand on the supply. This is
    important in marine situations where generator
    sets are used for reticulation.
  • Related VS i II Functions Current Limit, Current
    Ramp

66
Soft Start Benefits for Winches
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Provides reliable motor protection while allowing
    the winch to ride through temporary overload
    situations.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

67
Soft Start Benefits for Winches
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor caused by a
    jammed or excessively overloaded winch during
    start up.
  • Related VS i II Function Excess Start Time
  • Instantaneous Overload Protection
  • Motor current is monitored and if the level
    detected is higher than that of the instantaneous
    overload protection, the VS i II will immediately
    trip.
  • This will prevent damage to the motor, winch line
    and couplings caused by severe overload or a
    stalled winch line.
  • Related VS i II Function Fixed at 600 of Motor
    FLC

68
Soft Start Benefits for Screens
  • Gentle Acceleration
  • Reduces mechanical stress on couplings bearings
    and other moving parts extending equipment life
    and lowering maintenance costs.
  • Related VS i II Functions Current Limit, Current
    Ramp
  • Minimum Start Current
  • Reduces electrical disturbance on the supply by
    minimising the required start current. This is
    important at remote sites where supply is
    limited.
  • Related VS i II Functions Current Limit, Current
    Ramp

69
Soft Start Benefits for Screens
  • Motor Overload Protection
  • The VS i II allows the maximum time that the
    motor can run at locked rotor current at 600.
  • Maximum product throughput can be achieved
    without the risk of motor failure.
  • Related VS i II Function Motor Trip Class
  • Motor Thermistor Protection
  • Motor thermistors can be connected directly into
    the VS i II thermistor input.
  • This eliminates the need for special control
    equipment to be installed.
  • Related VS i II Function Thermistor Input
    Terminals

70
Soft Start Benefits for Screens
  • Excess Start Time
  • If a successful start is not achieved within the
    excess start time setting, the VS i II will trip.
  • This will prevent damage to the motor and other
    moving equipment caused by jamming during start
    up.
  • Related VS i II Function Excess Start Time