Title: Sales Opportunities
1Sales Opportunities
VersiStart i II
2VersiStart i II Range
- Ranges
- 23 Models
- 18A 200A
- 7.5kW 220kW _at_ 400VAC
- Voltage Ranges
- 200 440VAC
- 200 575VAC
- Protection
- IP20 18 100 A 140 200 A (when
installed with optional finger
guards) - IP00 140 200 A
- Certification
-
3VersiStart i II Highlights
- Easy and economic to install
- Soft start/stop plus motor/system protection
- Fast and easy to configure
- Compact design minimises panel space
- Integrated bypass
- Relay outputs to assist system integration
- Offers the most popular soft start and soft stop
methods - Essential motor and system protection
- Built-in thermal model
- Balanced Vector Control
- Serial Communication Modules Modbus, DeviceNet,
Profibus, USB
4Industry Types
Water Supply Local government, water utilities etc
Water Treatment Local government, waste water
sewage utilities etc
Irrigation
Food Beverage Slaughter houses, frozen foods,
cool stores, beverage manufacturers etc
Forestry Saw Mills, Pulp Paper Processors etc
Quarries Mining
HVAC Building Services
Petrochemical Production
Marine
Generator Set Supplies
5Water Supply
Pumps
6Water Treatment
Pumps
Aerators
Milliscreens
7Irrigation
Pumps
8Food and Beverage
Pumps
Compressors
Conveyors
Fans
9Forestry
Slabber
Chippers
Edgers
Debarkers
Hydraulic Power Packs
Fans
Refiners
Pumps
10Quarrying and Mining
Crushers
Conveyors
Screens
Fans
Pumps
11HVAC Building Services
Chiller Compressors
Fans
Pumps
12Petrochemical Production
Compressors
Fans
Pumps
13Marine
Winches
Compressors
Fans
Pumps
14Generator Set Supplies
Large Machines run off Limited Supplies
15Soft Start Benefits for Pumps
- Gentle Acceleration
- Minimises pressure surges during start thus
preventing mechanical damage to pipes, valves,
transducers, etc. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply.
This is very important where large pumps are
installed in residential areas. - Limits demand on the supply. This can reduce
reticulation costs when supplying power to large
pumps installed in remote areas, e.g. farm
irrigation pumps. - Related VS i II Functions Current Limit ,Current
Ramp
16Soft Start Benefits for Pumps
- Soft Stop
- Timed Voltage Ramp extends and control the pump
stopping, eliminating the damaging effects of
fluid hammer often associated with uncontrolled
pump stopping. - This will reduce the need for regular
maintenance/repair and extend the life of pumps,
valves, pipes, transducers, etc. - New installation costs can be reduced because the
system design need not allow for repetitive high
pressure surges. For example, pressure surge
tanks and motorised valves become unneccessary
and the specification of pipes, valves,
transducers, etc, can be reduced. - Related VS i II Function Soft Stop Time
17Soft Start Benefits for Pumps
- Motor Overload Protection - Dual Thermal Model
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - In the petrochemical industry this feature can be
vital for safety. If excessive motor temperature
goes undetected, a hazardous situation exists. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
18Soft Start Benefits for Pumps
- Phase Sequence Protection
- The sequence of the incoming three phase supply
is monitored. If a change is detected, the VS i
II will prevent a start. - This is important in applications where damage
can occur if the pump runs in reverse direction. - Related VS i II Function Phase Sequence
Protection
19Soft Start Benefits for Pumps
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor in the
event of a jammed or stalled pump. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that set for the
instantaneous overload protection, the VS i II
will immediately trip. - This will prevent damage to the motor, pump and
couplings caused by abnormally large solids
jamming the pump, eg tree debris in a flood pump
or large rocks in a slurry pump. - Related VS i II Function Fixed at 600 of Motor
FLC
20Soft Start Benefits for Compressor Chillers
- Gentle Acceleration
- Minimises torque transients during start thus
preventing mechanical damage to couplings, belts,
bearings and the compressor. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply.
- Related VS i II Functions Current Limit,
Current Ramp - Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Related VS i II Function Motor Trip Class
21Soft Start Benefits for Compressor Chillers
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals - Phase Sequence Protection
- The rotation of the incoming three phase supply
is monitored. If a change is detected, the VS i
II will prevent a start. - This is important in applications where damage
can occur if the compressor runs in reverse
direction. - Related VS i II Function Phase Sequence
Protection
22Soft Start Benefits for Compressor Chillers
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor in the
event of a jammed or stalled compressor. - It can also detect failure of the Off Loader
device. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the Instantaneous
overload protection, the VS i II will immediately
trip. - This will prevent damage to the motor, compressor
and couplings caused by a lock up situation. eg
liquid ammonia entering the compressor. - Related VS i II Function Fixed at 600 of Motor
FLC
23Soft Start Benefits for Fans
- Gentle Acceleration
- Minimises torque transients during start thus
preventing mechanical damage to couplings, belts
and bearings. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply.
- Related VS i II Functions Current Limit, Current
Ramp - Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Related VS i II Function Motor Trip Class
24Soft Start Benefits for Fans
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals - Phase Sequence Protection
- The rotation of the incoming three phase supply
is monitored. If a change is detected, the VS i
II will prevent a start. - This is important in applications where damage
may occur if the fan runs in reverse direction. - Related VS i II Function Phase Sequence
Protection
25Soft Start Benefits for Fans
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor in the
event of a jammed or stalled fan. - Can give early indication of bearing failure.
- Related VS i II Function Excess Start Time
- Fan Load Monitoring
- Via an optional remote operator a 4-20mA analogue
output can be used to monitor the fan loading.
This allows the VS i II to be directly interfaced
with a building management system without the
need for extra equipment. - Related VS i II Function 4-20mA Output (Motor
Current)
26Soft Start Benefits for Conveyors
- Gentle Acceleration
- Minimises torque transients and extends starting
time for gentle run up of the conveyor. - Reduces the risk of product damage caused by
jerky starts. - Provides optimimum conveyor starting regardless
of product loading, i.e. loaded/unloaded. - Prevents mechanical damage to couplings, belts
and bearings. - Prevents conveyor belt slap during start.
- Reduces stress on counter balances and weights.
- Related VS i II Functions Current Limit, Current
Ramp
27Soft Start Benefits for Conveyors
- Minimum start current
- Reduces electrical disturbance on the supply.
- Related VS i II Functions Current Limit, Current
Ramp - Soft Stop
- Extends conveyor stopping time thus reducing the
risk of product damage caused by sudden stops. - Related VS i II Functions Soft Stop Time
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Related VS i II Function Motor Trip Class
28Soft Start Benefits for Conveyors
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals - Phase Sequence Protection
- The rotation of the incoming three phase supply
is monitored. If a change is detected, the VS i
II will prevent a start. - This is important in applications where damage
can occur if the conveyor runs in reverse
direction. - Related VS i II Function Phase Sequence
Protection
29Soft Start Benefits for Conveyors
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor caused by a
jammed or excessively overloaded conveyor during
start up. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will immediately
trip. - This will prevent damage to the motor, conveyor
and couplings caused by severe product overload
or a stalled conveyor . - Related VS i II Function Fixed at 600 of Motor
FLC
30Soft Start Benefits for Crushers
- Gentle Acceleration
- Minimises torque transients for gentle crusher
starting thus extending coupling, belt and
bearing life. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply.
- Limits the demand on the supply. This is
important in remote sites where generator sets
are used for reticulation. - Related VS i II Functions Current Limit, Current
Ramp
31Soft Start Benefits for Crushers
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Maximises product throughput by allowing the
motor to operate at its upper thermal limit. - Provides reliable motor protection while allowing
the crusher to ride through temporary product
overload situations. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
32Soft Start Benefits for Crushers
- Phase Sequence Protection
- The rotation of the incoming three phase supply
is monitored. If a change is detected, the VS i
II will prevent a start. - This is important in applications where damage
can occur if the crusher runs in reverse
direction. - Related VS i II Function Phase Sequence
Protection - Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor caused by a
jammed or excessively overloaded crusher during
start up. - Related VS i II Function Excess Start Time
33Soft Start Benefits for Crushers
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will immediately
trip. - This will prevent damage to the motor, crusher
and couplings caused by severe product overload
or a stalled crusher while running, eg, oversized
rock jammed in crusher rollers. - Related VS i II Function Fixed at 600 of Motor
FLC - Crusher Load Monitoring and Control
- Via an optional remote operator a 4-20mA analogue
output can be used to monitor the crusher
loading. This allows the VS i II to be directly
interfaced with the infeed conveyor control
system to maximise product throughput. - Related VS i II Function 4-20mA Output (Motor
Current)
34Soft Start Benefits for Generator Sets
- Optimum Starting Performance
- The VS i II will optimise the starting
performance of any motor supplied by a generator
set. - Start current is minimised reducing the kVA
demand on the alternator and the kW demand on the
primemover. - Load is gradually applied to the alternator. This
will assist in maintaining a constant voltage and
frequency during start providing a more overall
stable system. - New motors may be used on existing generator sets
already operating at near full capacity. - Possibility of reduced generator set sizing on
new installations where motors are a signicant
part of the load. - Related VS i II Functions Current Limit, Current
Ramp
35Soft Start Benefits for Generator Sets
- Frequency Protection
- The VS i II monitors the supply frequency and can
be set to trip if it falls outside the protection
tolerance. This is useful on generator set
applications for detecting under and over
frequency situations. The allowable frequency
tolerance is greater during start enabling the
generator set to ride through the motor starting
conditions. - Related VS i II Function 40Hz lt Operating Range
lt 72Hz - Phase Loss Protection
- Motor line currents are monitored and if a
programmed imbalance is detected the VS i II will
trip. This is useful for detecting a problem in
the alternator section of the generator set. - Related VS i II Function Highest and lowest
currents on the three phases vary by an average
of 30 for more than 3 seconds.
36Soft Start Benefits for Generator Sets
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will immediately
trip. - Severe overload situations can cause the
generator set to become unstable and run below
its safe operating speed. This can be avoided
using the instantaneous overload protection
function. - Related VS i II Function Fixed at 600 of Motor
FLC
37Soft Start Benefits for Chippers
- Gentle Acceleration
- Minimises torque transients for a gentle run up
of the chipper. This reduces mechanical stress on
couplings, belts and knife blades thus lowering
maintenance costs. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply by
minimising the required start current. This is
important at remote sites where supply is
limited. - Related VS i II Functions Current Limit, Current
Ramp.
38Soft Start Benefits for Chippers
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Maximum product throughput can be achieved
without the risk of motor failure. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
39Soft Start Benefits for Chippers
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor and knife
blades caused by a jammed or excessively
overloaded chipper during start up. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will immediately
trip. - Lock up situations are common in chipper
applications. Instantaneous overload protection
will reduce the risk of knifeblade damage due to
torque shocks experienced under these conditions - Related VS i II Function Fixed at 600 of Motor
FLC
40Soft Start Benefits for Chippers
- Chipper Load Monitoring and Control
- Via an optional remote operator a 4-20mA analogue
output signal can be used to monitor chipper
loading and can be interfaced with the infeed
conveyor control system to maximise product
throughput. - Related VS i II Function 4-20mA Output (Motor
Current)
41Soft Start Benefits for Aerators
- Gentle Acceleration
- Increases mechanical stability during start up to
reduce risk of tipping. - Minimises torque transients during start thus
preventing mechanical damage to couplings and
bearings. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply.
- Related VS i II Functions Current Limit, Current
Ramp
42Soft Start Benefits for Aerators
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
43Soft Start Benefits for Aerators
- Phase Sequence Protection
- The rotation of the incoming three phase supply
is monitored. If a change is detected, the VS i
II will prevent a start. - This is important in applications where damage
can occur if the aerator runs in reverse
direction. - Related VS i II Function Phase Sequence
Protection
44Soft Start Benefits for Milliscreens
- Gentle Acceleration
- Milliscreens commonly use small motors with
gearboxes to produce high output torque. The VS i
II will reduce mechanical stress on gearboxes,
couplings, belts and bearings. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply.
- Related VS i II Functions Current Limit, Current
Ramp - Motor Overload Protection
- The VS i II mathematically calculates the motor
windings and body temperature allowing for safe
use of the motors thermal capacity. - Related VS i II Function Motor Trip Class
45Soft Start Benefits for Milliscreens
- Phase Sequence Protection
- The rotation of the incoming three phase supply
is monitored. If a change is detected, the VS i
II will prevent a start. - This is important as damage can occur to the
gearbox and milliscreen if run in reverse
direction. - Related VS i II Function Phase Sequence
Protection - Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor caused by a
seized gearbox, couplings, belts and bearings
during start up. - Related VS i II Function Excess Start Time
46Soft Start Benefits for Slabbers
- Gentle Acceleration
- Minimises torque transients for a gentle run up
of the slabber. This reduces mechanical stress on
couplings and saw blades extending equipment life
and lowering maintenance costs. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply by
minimising the required start current. This is
important at remote sites where supply is
limited. - Related VS i II Functions Current Limit, Current
Ramp
47Soft Start Benefits for Slabbers
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Maximum product throughput can be achieved
without the risk of motor failure. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
48Soft Start Benefits for Slabbers
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor and saw
blades caused by a jammed or excessively
overloaded slabber during start up. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will immediately
trip. - Lock up situations are common in slabber
applications. Instantaneous overload protection
will reduce the risk of sawblade damage due to
torque shocks experienced under these conditions - Related VS i II Function Fixed at 600 of Motor
FLC
49Soft Start Benefits for Slabbers
- Slabber Load Monitoring and Control
- Via an optional remote operator a 4-20mA analogue
output signal can be used to monitor slabber
loading and can be interfaced with the infeed
conveyor control system to maximise product
throughput. - Related VS i II Function 4-20mA Output (Motor
Current)
50Soft Start Benefits for Edgers Arbors
- Gentle Acceleration
- Minimises torque transients for a gentle run up
of the edger. - Reduces mechanical stress on couplings and saw
blades extending equipment life and lowering
maintenance costs. - Prevents sawblade de-alignment.
- Related VS i II Functions Current Limit, Current
Ramp -
- Minimum Start Current
- Reduces electrical disturbance on the supply by
minimising the required start current. This is
important at remote sites where supply is
limited. - Related VS i II Functions Current Limit, Current
Ramp
51Soft Start Benefits for Edgers Arbors
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Motor thermal model will provide optimum
protection without nuisance tripping. - Maximum product throughput can be achieved
without the risk of motor failure. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
52Soft Start Benefits for Edgers Arbors
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor and saw
blades caused by a jammed or excessively
overloaded edger during start up. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will
immediately trip. - Jamming is common in edger applications.
Instantaneous overload protection will reduce the
risk of sawblade damage and de-alignment under
these conditions. - Related VS i II Function Fixed at 600 of Motor
FLC
53Soft Start Benefits for Edgers Arbors
- Edger Load Monitoring and Control
- Via an optional remote operator a 4-20mA analogue
output signal can be used to monitor edger
loading and can be interfaced with the infeed
conveyor control system to maximise product
throughput. - Related VS i II Function 4-20mA Output (Motor
Current) -
54Soft Start Benefits for Debarkers
- Gentle Acceleration
- Minimises torque transients for a gentle run up
of the debarker. - Reduces mechanical stress on couplings and saw
blades extending equipment life and lowering
maintenance costs. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply by
minimising the required start current. This is
important at remote sites where supply is
limited. - Related VS i II Functions Current Limit, Current
Ramp
55Soft Start Benefits for Debarkers
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Motor thermal model will provide optimum
protection without nusiance tripping. - Maximum product throughput can be achieved
without the risk of motor failure. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
56Soft Start Benefits for Debarkers
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor, ring gear
and saw blades caused by a jammed or excessively
overloaded debarker during start up. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will
immediately trip. - In the case of a jammed log, instantaneous
overload protection will reduce the risk of ring
gear and saw blade damage. - Related VS i II Function Fixed at 600 of Motor
FLC
57Soft Start Benefits for Debarkers
- Debarker Load Monitoring and Control
- Via an optional remote operator a 4-20mA analogue
output signal can be used to monitor edger
loading and can be interfaced with the infeed
conveyor control system to maximise product
throughput. - Related VS i II Function 4-20mA Output (Motor
Current)
58Soft Start Benefits for Hydraulic Power Packs
- Gentle Acceleration
- Hydraulic Power Packs are commonly used to power
conveyor systems which feed logs through process
machinery. Torque transients are minimised for a
gentle run up. - Reduces mechanical stress on fluid couplings and
other moving parts extending equipment life and
lowering maintenance costs. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply by
minimising the required start current. This is
important at remote sites where supply is
limited. - Related VS i II Functions Current Limit, Current
Ramp
59Soft Start Benefits for Hydraulic Power Packs
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Maximum product throughput can be achieved
without the risk of motor failure. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
60Soft Start Benefits for Hydraulic Power Packs
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor and other
moving equipment caused by a jammed log in the
process line during start up. - Related VS i II Function Excess Start Time
-
61Soft Start Benefits for Refiners
- Gentle Acceleration
- Minimises torque transients for a gentle run up
of the refiner. This reduces mechanical stress on
couplings, belts and knife blades thus lowering
maintenance costs. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply by
minimising the required start current. This is
important at remote sites where supply is
limited. - Related VS i II Functions Current Limit, Current
Ramp
62Soft Start Benefits for Refiners
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Maximum product throughput can be achieved
without the risk of motor failure. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
63Soft Start Benefits for Refiners
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor and knife
blades caused by a jammed or excessively
overloaded refiner during start up. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will immediately
trip. - Lock up situations are common in refiner
applications. Instantaneous overload protection
will reduce the risk of knifeblade damage due to
torque shocks experienced under these conditions. - Related VS i II Function Fixed at 600 of Motor
FLC
64Soft Start Benefits for Refiners
- Refiner Load Monitoring and Control
- Via an optional remote operator a 4-20mA analogue
output signal can be used to monitor edger
loading and can be interfaced with the infeed
conveyor control system to maximise product
throughput. - Related VS i II Function 4-20mA Output (Motor
Current)
65Soft Start Benefits for Winches
- Gentle Acceleration
- Minimises torque transients for gentle winch
starting thus extending coupling, winch line and
bearing life. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply.
- Limits the demand on the supply. This is
important in marine situations where generator
sets are used for reticulation. - Related VS i II Functions Current Limit, Current
Ramp
66Soft Start Benefits for Winches
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Provides reliable motor protection while allowing
the winch to ride through temporary overload
situations. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
67Soft Start Benefits for Winches
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor caused by a
jammed or excessively overloaded winch during
start up. - Related VS i II Function Excess Start Time
- Instantaneous Overload Protection
- Motor current is monitored and if the level
detected is higher than that of the instantaneous
overload protection, the VS i II will immediately
trip. - This will prevent damage to the motor, winch line
and couplings caused by severe overload or a
stalled winch line. - Related VS i II Function Fixed at 600 of Motor
FLC
68Soft Start Benefits for Screens
- Gentle Acceleration
- Reduces mechanical stress on couplings bearings
and other moving parts extending equipment life
and lowering maintenance costs. - Related VS i II Functions Current Limit, Current
Ramp - Minimum Start Current
- Reduces electrical disturbance on the supply by
minimising the required start current. This is
important at remote sites where supply is
limited. - Related VS i II Functions Current Limit, Current
Ramp
69Soft Start Benefits for Screens
- Motor Overload Protection
- The VS i II allows the maximum time that the
motor can run at locked rotor current at 600. - Maximum product throughput can be achieved
without the risk of motor failure. - Related VS i II Function Motor Trip Class
- Motor Thermistor Protection
- Motor thermistors can be connected directly into
the VS i II thermistor input. - This eliminates the need for special control
equipment to be installed. - Related VS i II Function Thermistor Input
Terminals
70Soft Start Benefits for Screens
- Excess Start Time
- If a successful start is not achieved within the
excess start time setting, the VS i II will trip.
- This will prevent damage to the motor and other
moving equipment caused by jamming during start
up. - Related VS i II Function Excess Start Time
-