Title: ACTIVA ROOFTOP 45-90kW
1ACTIVA ROOFTOP 45-90kW
Product Presentation
2Contents
- Customer Value Proposition
- ACTIVA rooftops at a glance
- Construction Details
- Features benefits
- New Option Accessories
- Competition Comparison
- Documentation
- Future Strategy
3Customer value proposition
- The new ACTIVA rooftops come to cover our
customer needs, as they use R410A refrigerant,
are better performing than existing units, and
incorporate many new features which are more and
more demanded in the market.
4ACTIVA rooftops at a glance
- Main Advantages Features
- R410A Refrigerant
- Improved efficiency and low noise level
- Tandem configuration (up to 52ºC with 1 comp.)
- New models HP Gas
- Sizes 45 -60-75-90 kW
- New PCB YKN2Open (JCI protocol)
- New options and accessories
- Energy recovery
- Return fan
- F6, F7 filters as options G4 as std pre-filter
100 Compatible with existing roofcurbs(suituable
for JCI Rooftop replacement)
5Construction Details
Upper View
Isometric View
ELECTRICAL BOX
AR_ 45/60
EVAPORATING SECTION
CONDENSING SECTION
AIR FILTERS
Outdoor Air
ReturnAir
SupplyAir
6Construction Details
Pressure gauges
Charge valves
7Features Benefits
- TANDEM CIRCUIT
- Possibility to work at partial load
- Higher efficiencies when working at partial load
- Higher lock-out temperatures (up to 52º
whenworking at partial load) - Less piping components
- Cost Saving
8Features Benefits
New Board and control YKN2Open
- Auto restart and Random start
- Last 10 lockouts stored in a non-volatile memory
- Compressors runtime priority
- Lockout and Incident level of protections
- Reset the lockout from thermostat
- Unique defrost strategy with coil dry cycle
included - 4 stages Hot water coil with minimum supply air
temp
9Features Benefits
- New quiet outdoor fan with external bell to
reduce air turbulences and sound level while
increasing efficiency
10Features Benefits
- Liquid line filter-dryer - Discharge
temperature cut-off switch - - Suction
accumulator (on heat pumps) - Liquid sight
glasses - Crankcase heater
- High and low pressure switches - Suction line
antifreeze thermostat
11Features Benefits
12Features Benefits
Full range of OPTIONS ACCESSORIES available
13New Options AccessoriesENERGY RECOVERY
- Energy Recovery The concept
14New Options AccessoriesENERGY RECOVERY
Energy Recovery in ACTIVA
15New Options AccessoriesENERGY RECOVERY
- Energy Recovery in ACTIVA
- Enthalpy wheel
- Energy recover for sensible and latent heat (?
75) - Wheel material imbedded in matrix (Silica gel)
- Casing made in stainless steel.
- Permanently lubricated bearings 20 years
lifetime min! - Easy to clean
- Airflow adjustment in installation
16New Options AccessoriesENERGY RECOVERY
- Energy Recovery Most commonly used technologies
Total energy recovered (kWh)
Heat Pipe
Active Recovery
Energy needs
Entalphy Wheel
Plate ex-changer
Water Glycol
17New Options AccessoriesRETURN FAN
- Return Fan EC plug technology with backguard
blades - Automatic fan speed control through EC
Technology - More efficient
- Quiet operation (no magnetic noise)
- Differential pressure sensors to automatically
adjust the airflow to the setting point - Compact design
- Easy installation and set up
- Soft start
- Motor protection included
- Counterrotating flaps to release excess of
pressure
18New Options AccessoriesRETURN FAN
Return fan Why EC?
19New Options AccessoriesAIR FILTERING
Gravimetric efficiencyAm()
Filter Class
Opacimetric efficiencyEm()
As per EN 779
Delivered as standard
Available as Option for Rooftop and Heat Recovery
20Competitors Comparison
21Competitors Comparison
Source Eurovent
22Documentation
- Technical Documentation
- New look, easy to read, with more detailed user
information, installation instructions and tech
specs, supported by more pictures, Warnings,
potential risks and safety advices. - Delivered wit the unit 4 separate documents
CD - Generalities Describes a short Introduction to
the product, unit identification, Plate
descriptions (serial number and rating plate), CE
Declaration and manufacturer contact. - User Guide Description of the unit, operation
instructions, troubleshooting, maintenanceAvaila
ble in 6 languages. - Quick Installation Guide Detailed information
that will drive you through the installation
process (placement, duct connection and
electrical wiring)Available in 6 languages - CD ROM Installation Contains info on how to
install the CD. - CD ROM Contains above mentioned information
Full
installation guide (including technical data)
All options and accessories
instructions in all 6 languages - Available languages EN ES FR GR IT - NL
23Documentation
- Technical Documentation
- Quick installation guide includes 4 pages to be
used as a checklist for commissioning and write
down installed data.
24Future and Strategy
- Current ACTIVA models will be complemented with
the rest of Rooftop product family, upgraded to
R410 Refrigerant - Small rooftops (up to 40kW) will be launched end
of 2010. Same features as ACTIVA and - 1 new size 17 kW
- Compact design
- Inverter supply fan
- IP54 as an option
- Large Rooftops (up to 180 kW) will be launched
summer 2011 with same features as ACTIVA and - 2 new sizes 100 180 kW (Range 100, 120, 150
180 kW) - Complete new cabinet new distribution
- Inverter supply fan
25THANKS FOR YOUR ATTENTION