Specifications for beam diagnostics C - PowerPoint PPT Presentation

About This Presentation
Title:

Specifications for beam diagnostics C

Description:

Title: LCLS R & D Author: Heinz-Dieter Nuhn Last modified by: limborg Created Date: 1/8/1998 9:45:11 PM Document presentation format: On-screen Show – PowerPoint PPT presentation

Number of Views:57
Avg rating:3.0/5.0
Slides: 23
Provided by: Heinz46
Category:

less

Transcript and Presenter's Notes

Title: Specifications for beam diagnostics C


1
Specifications for beam diagnostics Cécile
Limborg, SLACNovember 3, 2003
  • Thermal emittance measurement
  • Gun Spectrometer
  • Straight-Ahead Spectrometer
  • Direct measurements
  • With transverse deflecting cavity
  • Conclusions

2
(No Transcript)
3
Gun Spectrometer
4
Imaging on first screen
  • Uniformity of emission
  • Thermal emittance measurement Solenoid scan
  • Optimal screen position ( z gt 50 cm)
  • Solenoid scan (operating range) linear up to
    3.4kG

5
Thermal emittance measurement

Example of SDL Data
Method
6
Gun Spectrometer
7
Gun Spectrometer measurement
  • Measurements
  • Energy
  • Absolute energy
  • alignment using laser (YAG1 to entrance linac)
  • spectrometer field calibration
  • Correlated Energy Spread for all charges
  • Uncorrelated energy spread for low charges
  • Introducing a time-energy correlation (injection
    phase or unbalance)
  • Slice thermal emittance
  • Relay imaging system from YAG1 to spectrometer
    screens
  • Point-to-point imaging
  • Uniformity of line density

8
Gun Spectrometer measurement
  • Modes of operation
  • Nominal (quads off) point-to-point in both
    planes
  • Resolution 10 keV
  • Drawback large beam size on screen
  • Smaller beam size (quads on)
  • Resolution of 10keV
  • Good energy resolution and small beam size high
    R16 , low R11, zero R12 on secondary screen
  • Resolution of 3 keV
  • Small beam sizes

9
Gun SpectrometerMode1 No quadrupole on
Bending magnet ? 84.46 degrees ? 26.4 degrees
Resolving power ?xo atYAG1 1.78 mm (for
nominal case, 1nC) ?xoR11lt ?? R16 ? ?? gt
2.3.10-3 ? ?E gt 12 keV
10
Gun SpectrometerMode1 No quadrupole on
At IMAGE (view screen 1, 1.5 diameter)
At SOURCE Nominal 1nC, 150keV Correlated energy
spread
11
Gun Spectrometer- Mode1 No quadrupole on
Low charge No correlated energy spread (by
adjusting ?inj or Field balance)
Resolution about 10 keV
12
Gun Spectrometer- Mode 2 quadrupoles on Screen
1
Resolution of 10 keV smaller beam size
13
Gun Spectrometer- Mode 3 quadrupoles on Screen
2
Resolution of 3 keV small beam size
14
Gun Spectrometer Can Measure Uniformity of Line
Charge Density
  • can resolve a minimum of 5 modulation at gun
    exit

15
End Spectrometer
  • 35 ? bending angle dipole magnet
  • Point-to-point imaging of the 75 ?m waist (OTR5)
    at 4.6 m from entrance spectrometer

16
End Spectrometer
  • Point-to-point imaging of the 75 ?m waist (OTR5)

17
End Spectrometer - Quadrupoles on
  • Various modes of operation with point-to-point
    imaging in both planes
  • R34 R12 0 , R16 -3 R11
  • Nominal tuning less than 10keV resolution
  • Reduced to 5 keV if beam size reduced to 37 ??m
    at waist

good resolving power, ?xoR11lt ?? R16
18
End-Spectrometer Used with Transverse Cavity

SOURCE Waist
IMAGE
Direct representation of Longitudinal Phase Space
19

Resolve less than 10 keV
20
CONCLUSIONS
  • Thermal emittance
  • Standard 3 screen emittance available
  • Gun Spectrometer design finalized
  • Absolute energy, energy spread
  • Uncorrelated energy spread for low charges
  • Slice thermal emittance
  • Longitudinal uniformity
  • End Spectrometer design finalized
  • Absolute energy
  • Slice emittance
  • Close to 5 keV resolution
  • Direct measurement of phase space

21
LIST OF REFERNCES
  • Diagnostics
  • 6 Gun Spectrometer C.Limborg , March 03
    updated October
  • 7 Gun Spectrometer, Revision 1, C.Limborg,
    LCLS-InJTech Note
  • 8 Gun Spectrometer, Revision 2, C.Limborg,
    LCLS-InJTech Note
  • 9 Straight-Ahead Spectrometer, C.Limborg,
    April 03, LCLS-InJTech Note
  • 10 Straight-Ahead Spectrometer, Revsion 1,
    C.Limborg, Oct03, LCLS-InJTech Note

22
  • BACK- UP
  • SLIDES
Write a Comment
User Comments (0)
About PowerShow.com