Title: AQ Overview
1AQ Overview
2AQ Definition
- Annual Quantity (AQ) is a value held for each
meter point that reflects the expectation as to
the volume of gas that a meter point will consume
within 1 gas year. The AQ is derived from
historic consumption and consumption patterns to
derive the most accurate AQ - AQs or derivatives of AQ, are utilised in many
xoserve and Shipper processes, including - Network Analysis Planning
- Energy Balancing
- Safety
- GT Pricing
- Billing / RbD Transportation Charges
- Read Frequency
- Emergency Contacts
- Site Classification
31 AQ System Calculation The Uniform Network
Code Defined AQ Calculation (NDM Only)
UNWC Section H.3
- RMQ Relevant Metered Quantity Calculation
- (Read 2 Read 1) Asset CV Value
(No. Of Days 365) - Calculation of Consumption Only Not AQ
- Actual Uniform Network Code Defined xoserve
System Calculation (H.3.4.1)
RMQ Relevant metered Quantity or Consumption
based on Reads and Asset INCLUDES Actual CV
values and not default value
CWAALP Cumulative Weather Adjusted Annual Load
Profile Includes Daily Adjustment Factors, Load
Profiles, Normal Seasonal Variables, Weather
Sensitivity etc. for both actual and forecasts
41 AQ Calculation Important Points
- AQ System Calculation will use any valid read on
xoserve systems. - Aim to identify erroneous AQ calculations.
- System Calculation starts in April each year.
- If system is unable to determine 2 reads within
specified parameters, AQ will be Carried Forward
same AQ Value for previous Gas Year will be
applied in next Gas Year. - Manual Analysis will take place on
- Threshold Crossers
- LSP AQ Calculation
- WC Calculation
- Primes Subs
5Section 1 AQ System Calculation Daily Metered
(DM) AQ Calculation
UNWC Section G.1.6.2
System Calculation Date
DM Consumption 1 YEAR
Consumption 1 Start Read
Consumption 2 End Read
- 1 Years Consumption for DM sites is 365 Days (or
366 days for Leap Years)
- Reads on a day denote the end of the previous
days consumption, therefore consumption 365 (End
Read) will be derived from the read on day 366
- DM AQs are NOT Adjusted to seasonal normal
temperature (NDM AQs are)
61 AQ System Calculation Non-Daily Metered
(NDM) AQ Calculation
UNWC Section H.3
D - 3Years
Target Read Date
System Calculation Date
NDM Consumption End Read minus 42 / 50 Weeks
End Read
Start Read OR Start Read
Read 2 minus 6 Months 1 Day
- All Reads used in System AQ Calculation have to
be within 3 years of the calculation date. - End Read is the latest dated valid read prior to
the system calculation - Target Read Date (Start Read) is End Read minus
50 weeks for Monthly Read Meters, 42 Weeks for
Non-Monthly Read Meters - Start Read is the latest valid read prior to
Target Read Date (but not less than 3 years since
calculation date) OR if no valid read exists
before the Target Read Date, the earliest dated
read after the Target Read Date BUT before the
End Read minus 6 months 1 day - If no valid read exists earlier than the End Read
minus 6 months and 1 day, no AQ calculation will
take place, current AQ will be carried forward
7AQ Timetable
- April xoserve Recalculates SSP Meter Point AQs
- May xoserve Recalculates LSP Meter Point AQs
- May xoserve Recalculates Meter Point Winter
Consumptions (WC) - By June 6th All SSP Threshold Crosser T04
Notification Files Released - June 7th SSP AMENDMENT WINDOW OPENS
- By June 30th All LSP T04 Notification Files
Released - July 1st LSP AMENDMENT WINDOW OPENS
- July 31st AQ Appeals Window Closes
- August 13th Last Day For Shipper Amendment Files
- September 1st Supply Point Revision Commences
- September 14th NRO / NRL Files Released to
Shippers (S91, S92, T68) - September 15th Appeals Window Opens
- October 1st AQs IMPLEMENTED
8Section 3 AQ Amendments
UNWC Section G.1.6
- An AQ Amendment is a challenge by the owning
Shipper to change the AQ Value to be applied on
1st October - Shipper is challenging the data that xoserve has
used to calculate AQ by using new or more valid
data - Amendments occur during the AQ Review period ONLY
- If the amendment is Accepted, the amended AQ will
go live automatically on 1st October - If the amendment is Rejected, the xoserve
calculated AQ will go live on 1st October
93 AQ Amendments Reasons For Amendment
UNWC Section G.1.6
- 1 Reads
- An Amendment can be submitted where
- The Read/s used by xoserve are incorrect
therefore resulting in an erroneous calculation
-The Shipper has more recent reads available than
those used by xoserve - 2 Meter Asset Discrepancy
- An Amendment can be submitted where
- xoserve has calculated the AQ using incorrect
MATERIAL asset data. This Includes - Imperial / Metric Indicator
- No. of Dials
- No. of Units
- Correction Factor
- Each of the above will have a direct impact on
the calculated AQ - In addition to the Amendment, the Asset change
should be submitted to xoserve to ensure future
accuracy of consumption and AQ calculations
103 AQ Amendments Reasons For Amendment
UNWC Section G.1.6
- 3 Carry Forwards
- xoserve has been unable to recalculate the AQ
the current AQ is applied. Reasons for Carry
Forwards can include - xoserve has been unable to calculate an AQ due to
a lack of consumption history - Analysis has determined that the proposed AQ may
be erroneous - For Amendments where the Supply Point is a
Smaller Supply Point and will remain as a Smaller
Supply Point (lt73,200) - Amended AQ must change by /- 20
- The Shipper requested AQ is measured against the
xoserve proposed AQ (not current AQ) - Amendments within this tolerance will be
automatically rejected - N.B Uniform Network Code states Focus of
Amendments should be balanced Amendment requests
should reflect the true, seasonally adjusted,
annual consumption anticipated at the Supply
Meter Point requiring increases as well as
reductions in the AQ
11AQ Amendments
- Total AQ Amendments
Received 2,521,057 - Total Accepted 2,372,206 (94.1)
- Total Rejected 148,851 (5.9)
- - Inclusive of Referrals
- Total Referrals 12,647
- Total Accepted 4,943 (39.1)
- Total Rejected 7,704 (60.9)
AQ Review 2007
12Meter Points Calculated
- Large Supply Points
- Total Meter Points Calculated 421,704
- Current Energy 268 TWH
- First Sweep calc 272 TWH
- xoserve Calculated Energy 260 TWH
- Final Applied Energy 01/10 251 TWH
- (Incl. 4.5 TWH SSP - LSP 39,106 M.Points)
- Small Supply Points
- Total Meter Points Calculated 21,080,879
- Current Energy 399 TWH
- First Sweep calc 402 TWH
- xoserve Calculated Energy 395 TWH
- Final Applied Energy 01/10 385 TWH
- (Incl. 2.3 TWH LSP - SSP 51,491
M.Points) - Approximate figures
AQ Review 2007
13SSP Energy Movement
Small Supply Point (Domestic) Movement
AQ Review 2007
14WHAT IS AN AQ APPEAL?
- An AQ (Annual Quantity) Appeal is a challenge to
the current AQ value on UK Link. - The AQ Appeals window is open from 15th September
until 31st July - Applies to the following categories of site
- Large Supply Point to Large Supply Point Changes
- (gt73,200 to gt73,200)
- Small Supply Point to Large Supply Point Changes
- (lt73,201 to gt73,200)
- Large Supply Point to Smaller Supply Point
Changes - (gt73,200 to lt 73,201)
- Small Supply Point to Small Supply Point changes
cannot be Appealed
15AQ Appeal Process Flow
Shipper determines current AQ value is not
reflective of actual consumption
- Spec Calc File Rejected with Rejection Reason
- ASO File will include S72 Rejection Record
REJECT
Is AQ Acceptable?
Is AQ Acceptable?
- Shipper Submits Speculative Calculator Request
File - ASI File
- T19 Record
xoserve Responds with Speculative Calculation
Response File to Shipper ASO File T20
Record AC or RJ Outcome
Can An AQ Appeal Be Raised?
Can an AQ Appeal be raised?
Shipper Receives Recalculated AQ Value
NO
YES
ACCEPT
NO
YES
xoserve Responds to Appeal File to Shipper
APO File T18 Record AC, RJ or RF Outcome
- Shipper Submits Appeal File as Per Spec Calc
Response File - API File
- T17 Record
Shipper Receives Appeal File and submits
re-nomination confirmation using Appeal
Reference
ACCEPT
AQ Goes live on xoserve System on Confirmation
Effective Date
REJECT
Shipper unable to raise AQ Appeal AQ will be
recalculated during next AQ Review Shipper will
have opportunity to raise Amend
- Amendment File Rejected with Rejection Reason
- APO File will include S72 Rejection Record
16Exceptions
- Manual Appeals Non confirmed supply points where
the incoming shipper disagrees with the
prevailing site AQ - BTU Forms
-
- New Business Appeals Where RSU picks up a site
and believes AQ to be incorrect. - MOD99 Again on shipper transfer where a
domestic property has an AQ above the LSP
threshold (73,200 KwH per annum.) - Manifest Errors Where there is a dramatic
change in supply point usage. (E.G. site has
closed or built a new CHP system etc.)
17Appeal Activity 2007 January to October
N.B. The appeals window was closed from 31 July
to 15 September 2007.
AQ Review 2007
18Issues
- Xoserves role
- Change to xoserve workload - Flatter profile
- Amendments would no longer exist.
- Current process relies on xoserve impartiality
- No xoserve manual review before AQ reset
- Potential increase in meter read traffic. (Limit
of 400,000 meter reads per day.) - Changing the AQ.
- There could be more Appeals spread through the
year. - There could be a dramatic increase in read
replacement activity - Poor quality RGMA flows mean-
- Erroneous reads could load.
- Correct reads fail to load.
- How will read replacement work?
- A single read can be replaced up to 99 times
- Does this mean that the AQ can be altered 99
times? - Does this open up gaming issues.
- Replacement cannot be retrospective from an
energy perspective - Reconciliation would take place back to date of
original reading
19Issues 2
- Reconfirmation process.
- Would need to be at least 14 days before AQ could
go live. - NRL/NRO files to be issued
- Impacts on Gemini.
- Issues on shipper transfer.
- Potential to change AQs at a given point in time
(E.G. Monthly, Quarterly) - Which reads should be used to drive AQ changes?
- Cyclic
- Read replacements
- OSER
- POS Opening reads
- Not OPNT estimates
- Shippers could chose which meter reads to submit.
- Funding. Who pays?
- Networks
- User Pays
- Demand Estimation
-