Title: Matrix Saving and Restoring PLC Procedures


1
Saving and Restoring the PLC
2
Saving the PLC (LADDER)
External Media
NC HN123card (Virtual COS2 Side)
Project Save
Project Open
NC HN482card (SRAM/FROM)
NC HN163card (Real COS1 side)
PC side
FROM area
Temporary Storage Area
ROM Write
Save
Area for COS1
Onboard Edition area
Copy When Power is on
Open
Area for COS2
Execute Ladder
Edit/Monitor
1. Open ladder which is running in the NC on
onboard edition area.
2. Save the opened ladder to the external
media(USB, hard drive, etc)
Page 42 Matrix Maint Manual
3
Press DIAGNOS soft key
4
Press VERSION soft key
5
COS1
COS2
Versions of Ladders
Press LADDER MONITOR soft key
Drawing
6
Press ENVIRON SETTING soft key
7
Press CONNECT NC SETTING soft key
8
Select M01 on drop down menu and Press SET soft
key
Press far left F1 Display Menu Key once to get
the first screen menu
9
Step 1 (Open PLC)
Press NC FILE soft key
10
Press OPEN soft key
11
Make sure that all files are selected--should be
checked
Press OPEN soft key
12
Drawing
Press OK soft key
Press F1 Display Menu Key twice to get the first
screen menu
13
Step 2 (Save Project to External Media)
Press EXTERNAL FILE soft key
14
Press SAVE PROJECT soft key
15
Make sure that all files are selected--should be
checked
Press EXTERNAL SAVE soft key
16
Press DRIVE/PATH and select drive D for USB port
D\M01
Press PROJECT NAME and name ladder preferably
with version
17
Press SAVE soft key
18
Press OK soft key once ladder is saved to
external media
19
Windows Explorer
20
(No Transcript)
21
Ladder Files
22
  • Repeat all of the previous steps
  • Select M02 for virtual ladder save

23
Restoring the PLC (LADDER)
STEPS
1. Clear the ladder which runs in temporary
storage area
2. Open the project saved in external media onto
the onboard edition area
3. Load the opened ladder to the temporary
storage area in the NC
4. Save the ladder into the ROM area(HN482 card)
If steps 2 and 3 are performed without deleting
the ladder in step 1 then there will be two
different ladders registered
Must be in Privileged Mode to upload ladder
Page 45 Matrix Maint Manual
24
External Media
NC HN123card (Virtual COS2 Side)
Project Save
Project Open
NC HN482card (SRAM/FROM)
NC HN163card (Real COS1 side)
PC side
FROM area
Temporary Storage Area
ROM Write
Save
Area for COS1
Onboard Edition area
Copy When Power is on
Open
Area for COS2
Execute Ladder
Edit/Monitor
25
Press DIAGNOS soft key
26
Press VERSION soft key
27
Press LADDER MONITOR soft key
28
Press ENVIRON SETTING soft key
29
Press CONNECT NC SETTING soft key
30
Select M01 on drop down menu and Press SET soft
key
Press far left F1 Display Menu Key once to get
the first screen menu
31
Step 1
Press NC FILE soft key
Drawing
Drawing
32
Press DELETE soft key
33
Press SEL. ALL/CANCEL Soft key
34
Press DELETE Soft key
35
Press YES Soft key
36
May see this screen, if so press YES Soft key to
stop the ladder
37
Press OK Soft key
Press F1 Display Menu Key twice to get the first
screen menu
38
Step 2
Notice Message Displayed
Press EXTERNAL FILE Soft key
Drawing
Drawing
39
Press OPEN PROJECT Soft key
40
Select d drive and M01 folder
41
Select Lad_Real file for project to upload
42
Press SELECT Soft key
43
Make sure all files are checked if not press
SEL. ALL/CANCEL Soft key
Press OPEN Soft key
44
May or May not get this message
Press ALL YES Soft key
45
Press OK Soft key
Press F1 Display Menu Key twice to get the first
screen menu
46
Step 3
Drawing
Drawing
Press NC FILE Soft key
47
Press SAVE Soft key
48
Make sure that all files are checked
Press SAVE Soft key
49
Press OK Soft key
50
Step 4
Press ROM WRITE Soft key
Drawing
Drawing
51
Press YES Soft key
52
Very Important Step !
Press YES Soft key again to write ladder onto the
ROM
53
Press OK Soft key
Press far left F1 Display Menu Key once
54
Press PLC RUN/STOP Soft key
55
Press YES Soft key
Write a Comment
User Comments (0)