Operation of Radionuclide Identification Devices (RID) IdentiFINDER Ultra - PowerPoint PPT Presentation

1 / 15
About This Presentation
Title:

Operation of Radionuclide Identification Devices (RID) IdentiFINDER Ultra

Description:

Operation of Radionuclide Identification Devices (RID) IdentiFINDER Ultra – PowerPoint PPT presentation

Number of Views:211
Avg rating:3.0/5.0
Slides: 16
Provided by: KHC3
Category:

less

Transcript and Presenter's Notes

Title: Operation of Radionuclide Identification Devices (RID) IdentiFINDER Ultra


1
  • Operation of Radionuclide Identification
    Devices(RID) IdentiFINDER Ultra

2
Outline
  • ICX IdentiFINDER-Ultra components
  • Easy mode
  • Switching on/off
  • Dose rate mode
  • Finder mode
  • Identification mode
  • Data transfer to PC
  • Advanced mode

3
ICX IdentiFINDERUltra
  • Gamma detection
  • NaI(Tl)-crystal
  • GM tube
  • Neutron detection
  • He3 tube
  • External moderator
  • Gamma spectrometer
  • NaI(Tl)-crystal
  • Stabilization and recalibration (KCl-box)
    necessary

4
ICX IdentiFINDER-Ultra
NaI(Tl) detector
Green LED (connection to ext. power supply)
Orange LED (charging)
Display
Command line
Selection buttons
Blue LED (neutron indicator)
Red LED (gamma indicator)
Power on/off
Adapter for charging and PC connection
Battery case
5
Button Functions
  • Menu buttons (L, M, R)
  • Correspond to commands shown in the display
  • Power button to
  • Switch on (press shortly)
  • Switch off (press and hold for at least 3 sec.)
  • Acknowledge neutron alarm (press shortly to stop
    sound)

6
Switching on Ultra
  • Press power button shortly
  • System self check
  • Display indicates instruments status
  • Ultra ready for use when dose rate is displayed

7
Dose Rate Mode
Battery status
Logarithmic scale of dose rate
Dose rate
Neutron count rate
  • Command line
  • Search mode (FINDER)
  • Identification mode (IDENT)
  • Advanced mode (OPTIONS)

8
Finder Mode
Start finder mode away from the object and wait
for 10 sec (count down)
  • Press L command FINDER

9
Finder Mode
  • Display information
  • Auto scaling strip chart (most recent
    measurement displayed on the right)
  • Dose rate
  • Passing a Source
  • Peak appears
  • Dose rate increases
  • Safety alarm
  • Background
  • Statistical fluctuations
  • Dose rate low

10
Identification Mode
  • Press M command IDENT

Possible messages
  • Countdown 60 sec.
  • Distance indication

11
Identification Mode
  • Identification results
  • Up to 2 results
  • Confidence of identification
  • 10 very likely
  • 1 unlikely
  • very weak indication
  • Categorization
  • Industrial, Medical, Nuclear, NORM
  • Isotope (e.g. Ra-226)
  • Continue measurement (press L), if display
    shows Not in Library or a low confidence level
  • Save spectrum (press M)

12
Identification Mode
  • Save spectrum
  • Save as a new spectrum
  • (memory to store up to 100 spectra)
  • Overwrite old spectrum confirm overwriting

13
Identification Mode
  • Unclear results
  • Not in library
  • Activity too low
  • Special identification results
  • Uranium does not specify if source is natural,
    depleted or enriched Uranium
  • Am (Plutonium?) Am-241 is one of the daughter
    products of Plutonium Americium is possible
    indication of Plutonium

14
Data Transfer to PC
  • Connect Ultra to PC (USB-cable)
  • Start IdentiFINDER Transfer software on PC
  • Press Preview transfer of stored spectra from
    Ultra to PC
  • Select files from the Stored spectra folder
  • Use Destination PC directory to select
    destination folder
  • To save spectra press gt for one spectrum or
    gtgt for all spectra

15
Advanced Mode
  • Press R Command OPTIONS
  • Password required
Write a Comment
User Comments (0)
About PowerShow.com