Title: ACD Installation, Post LAT CDR
1ACD Installation, Post LAT CDR
March 08, 2004
- Response to GLAST LAT CDR RFA Number 13 MGSE
Detailed Dimension Study for ACD Installation - A) Perform detailed dimension study. Crane hook
height appears inadequate for installation of
ACD - See slides 3 and 4
- B) Provide information on the clean room
entrances and clearances that will exist when
equipment (including GSE) is brought in and out. - Large, Double Door to Class 100K Crane Room is
111 2,819 mm wide by 108 2,743 mm high - Small, Single Door to Class 100K Clean Room is
59 1,499 mm wide by 79 2,007 mm high - The LAT on the Integration Stand, the Low Profile
ACD Integration Stand and the 8 x 8 x 6.2 tall
ACD Dolly fits in Rm 104 See slide 5
2ACD Installation, Post CDR Concept
March 08, 2004
- SLAC will develop a low profile integration stand
- When ready for ACD mate operations, the LAT will
be lifted from the Rotation / Support Stand and
set onto the low profile stand - Next slide shows available clearances
- The available clearances assume an 8 203 mm
high spreader - Current welded joint analyses indicate that the
spreader needs to be at least 8 high (i.e.,
Rectangular Structural Steel Tubing that is also
6 wide and 0.375 thick) - 13.6 345 mm of room to operate crane along Z
(vertical)
3LAT With ACD To / From Rotation Stand
March 25, 2004
- Crane load block maximum height is 134 inches
3,403 mm (Hook removed) - No problem moving LAT to / from integration
stand - 13.6 345 mm Operable Height for Crane,
with Scale in the loop
Crane Load Block
Crane Lift Block attaches directly to Crane Scale
that attaches directly to Lift Spreader Post
21.2 538 mm
8,856 lbs
¾ OTS 316 CRES Turnbuckles Rated for 5,200 lbs
each
ACD Installed
6.0 152.4 mm
120.4 3,058 mm
53.0 1,346 mm
4ACD Installation, Low Profile Integration Stand
March 25, 2004
Crane Lift Block at high point
LAT 4x4 Lift Spreader, 8 203 mm High
Working Hook Height 10 254 mm
134 3,403 mm
124 3,150 mm
6.0 153 mm
ACD
96.9 2,461 mm
Low Profile ACD Integration Stand
TKRs
49.3 1,253 mm
18.0 457 mm
4 102 mm
5LAT With ACD To / From Rotation Stand
March 08, 2004
- All Required Hardware for ACD Integration Fits
in Room - ACD Low Profile Integration Stand and its Dolly
are within Cranes Pick Zone - ACD on Dolly easily fits through Double Doors (
LAT May require bagging during door opening
events)
ACD Low Profile Integration Stand
ACD on 8 by 8 Dolly
Integration Stand is Placed to Allow Range of
Motion for PAPs