Title: ID3000 2 to 8 Loop Intelligent Fire Alarm Panel
1ID3000 2 to 8 Loop Intelligent Fire Alarm Panel
2Applications
- Medium To Large Single/Multiple Building Systems
- Retrofit And New Construction
- Standalone Systems
- Networked Systems
3Hardware Overview
4Modular Design
BasicEquipment Kit
Cover(s)
Extension Chassis (if required)
Backbox(es)
Optional Expansion Modules (if required)
Power Supply
5Key Components
Backbox Power Supply
Basic Equipment Kit Covers
Batteries Extension Chassis
6Basic Equipment Kit
Expansion Cards
Base Card
ProcessorPCB
Main Chassis
Display PCB
7Basic Equipment Kit
- Extension Options
- Up to 3 Standard Loop Cards (LIB)
- Up to 3 Enhanced Loop Cards (E-LIB)
- One RS-232 Card
- One RS-485 Card
- One ID-Net Card
8BEK - Inputs Outputs
- Outputs
- A/B/C/D - Sounder or Relay programmable
- Sounder - rated _at_ 1A/30V each
- Dry contact relay - rated _at_ 1A/30V
- Fault and Fire Relays VF rated _at_ 1A/30V each
- Auxiliary 26-28Vdc outputs 1 and 2 both rated _at_
1A - Battery charger max 8.6A (130Ah batteries) when
used remotely.
9BEK - Inputs Outputs
- Inputs
- Mains - 230Vac 15 50/60 Hz
- Two addressable loops - 500mA/Loop
- Tamper switch input (VF dry contact)
- Communications
- RS232 Port 1
- PC Programming, internal printer option
- RS232 Port 2 (optional module)
- RS485 Port (optional module)
10Extension Chassis Options
Double Extension Chassis with 255 Zone Display
Module Kit
11Optional Expansion Modules
ID-Net Network Card
Printer Module Kit
Dual Loop Module Kit
Enhanced Dual Loop Module Kit
Isolated RS232 Module Kit
Isolated RS485 Module Kit
12Communication Modules
- RS232 Card Option
- Isolated port
- Third party interface
- External printer
- UniNet (NION) connection
- Pager interface
- VDU for terminal emulation
- RS485 Card Option
- Isolated
- Master/Slave network
- Repeaters
- Mimics
13Standard LIB Vs E-LIB
- LIB
- Handles communication only
- System CPU scans loops
- In case of main CPU failure all detection is
lost - Max. 512 devices per panel (EN54)
- E-LIB
- Powerful microprocessor
- Degrade mode
- In case of main CPU failure the E-LIB will still
activate sounder circuits 1-4 and the Fire Relay
when an alarm is received from the loop - Full 1584 device count on the panel (EN54)
14Power Supply Selection
Remote Battery/Charger Enclosure Kit
Power Supply Unit Kit 2.5 Amp
Universal PSU Kit 4.5A or 7.0A (External
enclosure or deep boxes only)
PSU DTP Booster Kit (4.5 or 7.0A PSU only)
15Power Supply Options
4.5A PSU mounts into the deep (extended) back box
2.5A PSU mounts on the side of the BEK
DTP Booster mounts on the side of the BEK
7A PSU mounts into the external charger/
battery enclosure
16Back box Options
Flush Mounting Bezels
Standard Back Box Kit
Backbox Extension Kit (available in standard
and deep)
Double Extended Backbox Kit (available in
standard and deep)
Extended Back Box Kit (available in standard
and deep)
17Backbox Options
Standarddepth
17Ah
17 Ah
12Ah
38Ah
38Ah
78Ah
Deep Boxes
Standard Extended Double Extended
External Box
18Cover/Door Kits
Security Door Kits (available for main
extension covers)
Main Cover Kit (High Security option)
Extension Cover Blanking Plate
Extension Cover Kit (High Security option)
Double Extension Cover Kit
1919 Rack Mounting Option
- 19 Rack Mounting Assembly for Basic Equipment
Kit - 6U x 19 Rack Mounting Assembly for 7A PSU
- 6U x 19 Rack Mounting Assembly for 64 Zone LED
Extension Chassis Printer Kit - 6U x 19 Rack Mounting Assembly for 256 Zone LED
Extension Chassis Kit - 6U x 19 Rack Mounting Assembly for Printer
- 3U x 19 Rack Blank Cover with Mains Termination
Kit - 6U x 19 Rack Blank Cover with Mains Termination
Kit - 3U x 19 Rack Mounting Assembly for Mimic Driver
Kit - 6U x 19 Rack Blank Cover
- 3U x 19 Rack Blank Cover
20Main User Interface
6 Line x 40 Character Graphic LCD
Navigation Keypad
Numeric Data Entry Enter/Cancel
Main Control Switches
Key switchAccess Level 2
System Status Indicators
21Main User Interface
- Fully EN54 compliant
- Simple tabbed menu navigation
- Prioritised event display (Automatically
displays highest priority event) - User in control has choice of what is displayed
- Simple lights and switches for common controls
- Top level info displayed
22Graphic Display
- Large 240 x 64 pixel LCD 6 lines x40 characters
- Short-cuts for test disablement
- Selection by direct addressing
- Displays
- Time and Date
- Active Point Count for each event
- Event type, index and actions
- Panel, Zone and Device descriptors
23Graphic Display
System Information on Windows Style Tabbed Screens
24Virtual Keyboard
Panel and Zone Text up to 32 Characters via
Keyboard ???? to Navigate and ? to Select
25Fire Alarm Display
Example - 3 Zones in Alarm 2 Devices Alarmed in
Zone 2 1 Device Alarmed in Zone 1 1 other
zone in Alarm - Press Zones in Alarm to view
others Use Navigation keys 46 to scroll through
zones and display other devices, date/time of
event and device value, etc. Short-cut key ?
selects either device or zone disablement.
26Fault Display
3 Zones are in FAULT with 4 events in the
system. Use ??to scroll through zones and ?? to
display device, type, value, etc.
27Disablement Display
142 Devices Disabled in 3 input zones. 12 devices
are disabled in Zone 2 (all input devices). No
outputs are disabled. Use ??to scroll through
zone list and ?? to see device details.
28Main Features
- Meets EN54 Parts 2 and 4
- Degraded mode of operation
- Enhanced LIB (parallel CPUs)
- Menu driven point/data access
- Multi-level operator password control
- Multiple language options
29Key Functions
- 9 sensitivity levels for Fire Pre-alarm
- Adjustable alarm fault verification delay
- Two-stage alarm operation
- Alarm silence/re-sound
- Sound general alarm (Evacuate)
- Day and Night modes
- Fire output(s) inhibit
- Internal and external printer options
30Key Functions
- Powerful Control-by-Event (CBE)
- Auto-Learn or PC programming
- Duplicate address detection
- One-man Walk Test with counter
- Output device test
- Daily high test
- 2 pulse rates for outputs
- Time of day functions
31System CapacityStand-Alone
- Up to 8 loops
- 198 (9999) devices per loop
- Up to 1584 devices
- Up to 255 zones
- Up to 7A PSU
- Up to 31 repeaters or mimics
- Up to 512 LEDs per controller
- 600 event history log
32System CapacityStand-Alone
- Four sounder circuits (NACs)
- Rated _at_ 1A each
- Two programmable as VF relaysrated _at_ 30Vdc/1A
- Two 24Vdc auxiliary outputs
- Rated at 1A each
- Two programmable inputs
- Fault and Fire relays
- VF rated _at_ 30Vdc/1A
- Two loops as standard
- One isolated RS232 port (optional)
- One isolated RS485 port (optional)
33System CapacityInterlinked
- Master/Slave interlink
- Up to 32 network nodes
- Maximum 8 panels
- Remainder repeaters and mimics
- Up to 64 loops in total
- Up to 12,672 devices in total
- Up to 2040 zones in total
- Up to 56A PSU in total
- Max. RS485 bus length of 3000m
34Configuration Tool
- Windows Operating Systems
- Standard Windows features (cut, copy, paste, etc)
- On-line error checking
- Software protection
- EN54 Network functions
- Easy report printouts
- Multi-lingual operation
35On-Site Configuration
- Multi-level password/key-switch access
- Level 2 Code 1/Keyswitch - Panel controls
menus - Level 3 Code 2 - Level 2 Configuration menus
- Level 3A Code 3 - Level 3 Advanced
Configuration - Panel settings
- Auto-learn facility
- Loop/Device configuration
- Text Editor (Virtual keyboard)
- Control matrix editor (512 lines)
- Network configuration