Title: Guardhouses and Security Booths
1 Guardhouses and Security Booths
2Security Station Floor Plan
38 x 8 (with or without a trailer)
48 x 8 SPECIFICATIONS
58 x 12 With or Without a Trailer
68 x 12 SPECIFICATIONS
78 x 16 with Restroom With or Without a
Trailer
88 x 16- SPECIFICATIONS
98.5 x 17 With RestroomWith or Without a
Trailer
108-6 X 17- SPECIFICATIONS
118 x 13(With or Without a Trailer)
128 X 13 - SPECIFICATIONS
138.5 x 14 With Restroom(With or Without a
Trailer)
148-6 X 14 SPECIFICATIONS
156 x 14 With Restroom (With or Without a
Trailer)
166 X 14 - SPECIFICATIONS
17Security Station Floor Plan
18Security Station
19(No Transcript)
20Trailer Mounted Option
Trailer HighlightsRadial tires 6 lug hub,
ST225/75/R15 LRD Gross vehicle weight rating
(GVW) of 10,000 lbs (18-20' trailer) or 15,000
lbs (24' trailer) All axles have brakesBuilding
FootprintActual Trailer Width 8'6" Trailer Bed
Width 6'11" 5/8"DIA. Zinc plated all-threaded
rods, on corners (8) Minimum tongue length of
4'Trailer ElementsExterior Structure HSS
5x2x.120 Interior Structure C3"x3.5 per linear
foot Threaded Rod Yield Strength 45ksi, handles
load of 8,900 lbs Dexter Spring 5,200 lb
axle Flashing 22 gauge galvanized steel
sheetTowing Specs7 Blade Trailer Connector for
electrical wiring Standard 2 - 5/16 ball
hitch Safety chains rated for 7,600 lbs.
each Other ItemsHitch Jack rated to hold 2,000
lbs Scissor Leveling Jacks (4) The trailer finish
is a 2 part process with an epoxy primer and a
urethane top coat Bracket-mounted trailer lights
for easy removal during building reapplication
after construction, with incandescent bulbs (8)
21Options AvailableAll Models
- Winco HPS6000HE - 5500 Watt Dual Fuel Generator
with Electric Start Honda Engine. - Bi-Fuel Carburetor and Gas Regulator
- Versatile generator runs on natural gas or
gasoline - 11-HP Electric Start Honda Engine
- Premium-quality, fuel-efficient engine with low
oil protection - Standard electric start w/ battery rack and
cables - Battery not included Group 20 or 24HL 300CCA(Not
Included) - Dual element air filter reduces maintenance
- Brushless Alternator
- Inherent voltage regulation protects electronics
from surges - Less than 6 THD (Total Harmonic Distortion)
- 100 copper windings, NEMA Class F insulation
- NOTICE BI-FUEL STARTING
- Bi-Fuel generators operating on vapor fuel ( NG)
- Must be started using the electric start system
provided. - You cannot hand crank the unit fast enough to
develop the proper - Vacuum to make the vapor fuel system work.
- WHEN USING VAPOR FUEL NEVER USE THE CHOKE
2212700 Hillcrest Rd. Dallas ,TX.
75230 1-972-864-7341 FAX 1-972-864-7313
morganbuildingsystems.com
A Founding Member of the Modular Building
Institute
24 hour Emergency number 214-697-3543