... or sensor , while bias applied to a varactor diode is automa-tically adjusted via PLL circuitry to maintain the RLC sensor at resonance. – PowerPoint PPT presentation

Number of Views:77
Avg rating:3.0/5.0
Slides: 7
Provided by: JriV53
Category:

less

Transcript and Presenter's Notes

Title: Bakalaureuset


1
Bakalaureusetöödest11.04.2012
2
Juri Babkin
  • Saatja-vastuvõtja tüüpi Foucault kardiograafi
    vastuvõtuploki ehitamine
  • Title of the work
  • Design of
  • the
  • Derector block / Transmitter Block
  • of the
  • Transmitter-Receiver Type
  • Foucault Cardiograph

3
  • Sisukord
  • 1. Valdkonna ülevaade
  • 1.1 Uurimismeetodid inimese südame tegevuse
    jälgimiseks millised on praegu kasutusel
  • 1.2 Pöörisvoolude uurimise ja kasutamise ajalugu
  • 1.3 Kirjanduse ülevaade
  • 1.3.1 Kokkuvõtte
  • 1.4 Saatja-vastuvõtja tüüpi Foucault
    kardiograafi ehitamine erinevused ja eelised
  • 1.5 Töö eesmark ja sellest tulenevad ülesanded
  • 2. Meetodid ja materjalid
  • 3. Tehtud töö kirjeldus
  • 4. Tulemused
  • 5. Arutelu
  • Kokkuvõte
  • Summary
  • Kasutatud kirjandus
  • Lisad

4
  • Meetodid ja materjalid
  • Tänapäevase bioelektrilise impedantsi mõõtja
    vajalikud omadused ja uued võimalused
    realiseerimiseks
  • Elektroonikaskeemide funktsionaalse simulatsiooni
    vahendid LT Spice näitel
  • Nõrkade analoogsignaalide töötlemise riistvarast
    lt(Gilberti rakk, voolupeegel, võimendi,
    induktiivpool jms.), kuidas nad töötavad.gt
  • lt Elektroonikakomponentide valiku põhimõtted ja
    valik käesoleval juhulgt
  • Lühiülevaade mikrokontrolleri XXXXX võimalustest
    (koodi näited?)
  • Montaažiplaatide trasseerimise probleem ja
    vahendid selle lahendamiseks

5
  • Meetodid ja materjalid Tehtud töö
  • Plaan
  • Foucault kardiograafi ehitus (üldskeem
    kirjeldusega)
  • Vastuvõtuploki ehitus skeemiga, skeemiosade
    seletused, kuidas nad töötavad.
  • Valitud komponendid ja paigutus plaadil
  • Mikrokontrolleri lahendused (koodi näited?)

6
Auto-Tuned Induction Coil Conductivity Sensor for
In-Vivo Human Tissue Measurements J. Heller and
J. R. Feldkamp Kimberly-Clark Corporation,
Corporate Research and Engineering 2100
Winchester Road, Neenah, WI 54956,
U.S.A Auto-tuned induction coil technology, based
upon phase-locked loop circuitry (PLL), was
developed and shown to be an effective tool for
in-vivo measurement of elect-rical conductivity
of human tissues. Because electrical contact is
not required, se-veral disadvantages of the
electrode method for conductivity determination
are avoi-ded, such as electrode polarization and
variable conductivity associated with the stratum
corneum of the epidermis. Fixed frequency
excitation is supplied to a paral-lel tuned RLC
circuit, or sensor, while bias applied to a
varactor diode is automa-tically adjusted via PLL
circuitry to maintain the RLC sensor at
resonance. Since re-sonant impedance of a coil
positioned near a conductive object is known to
be fre-quency dependent, such an arrangement
permits precise calibration of the sensor against
a set of standard Potassium Chloride solutions.
In our experiments, a two-layer spiral coil is
used with upper and lower spiral arms staggered
so as to reduce inter-winding coil capacitance.
Preliminary in-vivo testing was done on the
forearms of a single male subject as a prelude to
more extensive use in a clinical setting. In that
instance, electrical conductivity at the proximal
volar forearm location was shown to depend on
forearm elevation. Clinical studies using our
prototype, as well as further consideration of
the elevation effect, are discussed in a
companion paper. Keywords Induction coil,
electrical conductivity, phase-locked-loop, human
tissues, impedance, resonance