Title: REGISTRATION
1REGISTRATION
- ATEX II 1/2G Eex ia IIC T6
2ATEX is the Explosive Atmospheres directive 94/9
C which covers equipment used in hazardous
areas. ATEX adalah Explosive Atmosphares
(Atmosfer mudah meledak) instruksi 94/9 C yang
mencakup peralatan digunakan dalam daerah
berbahaya kebakaran.
Adopted in 1994 with a transition period ending
6/30/03. After this date, all products sold and
used in the EU must conform to requirements of
the directive. Diambil dalam tahun 1994 dengan
masa transisi akhir 30 Juni 2003. Setelah tanggal
tersebut, semua produk yang dijual dan digunakan
di Eropa harus memenuhi persyaratan instruksi
(94/9 C) / standard.
In order to sell/use hazardous area products in
Europe/Asia, CENELEC approval to the ATEX
directive is mandatory. Untuk menjual /
menggunakan produk dalam daerah berbahaya di
Eropa / Asia, persetujuan CENELEC terhadap
instruksi ATEX adalah mutlak.
3ATEX Groups
Apparatus Group I applies to mining
operations that may be endangered by methane gas
and/or combustible dusts Peralatan Group I
selalu dipakai di operasi pertambangan yang
mungkin berbahaya oleh gas metan dan / atau debu
mudah terbakar
Apparatus Group II applies to apparatus used in
all other areas that can be subject to the hazard
of an explosive atmosphere. Peralatan Group II
selalu dipakai pada peralatan yang digunakan di
semua daerah yang dapat berresiko bahaya atmosfir
mudah meledak.
Apparatus Group III applies to apparatus used
in areas with conductive dusts Peralatan Group
III selalu dipakai pada peralatan yang
digunakan dalam daerah berisi debu konduktif.
4ATEX Categories
Category 1 The apparatus is intended for use in
areas in which an explosive atmosphere is present
continuously or for long periods of time
(Zone 0 apparatus) Kategori 1 Peralatan
digunakan di daerah dimana atmosfir mudah meledak
ada secara terus menerus atau untuk perioda
waktu yang panjang (Peralatan Zona 0)
Category 2 - The apparatus is intended for use in
areas in which an explosive atmosphere occurs
occasionally (Zone 1 apparatus) Kategori 2
Peralatan digunakan di daerah dimana atmosfir
mudah meledak berada secara kadang-kadang
(Peralatan Zona 1)
Category 3 The apparatus is intended for use in
areas in which no occurrence of an explosive
atmosphere is expected. If it does occur, it is
only rarely or for a short period of time
(Zone 2 apparatus) Kategori 3 Peralatan
digunakan di daerah dimana atmosfir mudah meledak
tidak diharapkan ada. Jika itu terjadi, itu
hanya secara jarang atau untuk perioda waktu
singkat (Peralatan Zona 2)
G gases, liquids, vapors D dust G
gas, cair, uap D debu
5EEx Meets CENELEC Standards EEx Merujuk
Standar CENELEC
Ex Explosion Protected Meets IEC Standards Ex
Proteksi Ledakan Merujuk Standar IEC
AEx Equipment conforms to NEC AEx Peralatan
sesuai dengan NEC
6(No Transcript)
7GAS GROUP
8(No Transcript)