Title: Boiler Efficiency and Combustion Control
1Plant Wide Controller (PWC) Overview
Preferred Instruments a division of Preferred
Utilities Mfg. Corp.
2Plant Wide Controller
The Plant Wide ControllerTM (PWC) is a
state-of-the-art boiler sequencing, control and
monitoring system. The PWC combines innovative
ease of operation, communication and expansion
capabilities with boiler application expertise.
Off-the-shelf, standard modulating Lead-Lag
applications can be expanded to control
circulating water variable speed pumps and
isolation valves while monitoring the flame
safeguard and boiler control systems.
3Easy to Operate
Key lockable Door Security
4Easy to Operate
- Hardwired Control Switches Indications
Firing Rate Control Dial
Firing Rate Auto / Man
0 - 100 Bargraph
Boiler On-Off-Auto
Status Indications
5Easy to Operate
LCD Graphic Display and Keypad
- Easy to use displays for
- Boiler Plant Control Monitoring
- Historical Trending
- Alarm Event Handling
- Boiler Plant Setup
6Easy to Operate
Display Keys
- Home Page -
- Boiler Overview Display
- Arrow Keys -
- Move Cursor
- Menu, Page Up, Down -
- Display Selection
- Alarm List -
- Alarm, Event Display
- Alarm Silence PB
7Home Page
- Lead / Lag Control
- Start Qty Control
- Sequence Control
- Custom
- Lead Rotate
- Alarm Status
- Time / Date Stamped
- Header Status
- Pressure / Temperature
- Setpoint
- Outside Temperature
- Status
- Started Boilers
- Warming Boilers
- Modulating Boilers
- Tripped Boilers
8Alarm Event Summary
- Up to 200 Alarms Events
- First in - First out
- Operator Actions
- Events
- Alarms
- Time Date Stamped
9Historical Trending
- An Essential Monitoring Tool
- Multiple(4) Pen Charts
- 8 min, 40 min., and
- 2, 8, 24 hour charts
- 8 channel, 2 Hr Historical Memory - Standard
- 32 Mb Historical Memory - Optional
- 32 ch AI 32 ch DI every 15 seconds for 30 days
- 90 or more days for less channels with low
activity (depends on data compression efficiency)
10Easy Setup
- Fill In The Blanks
- Boiler Sequence
- PID Tuning
- Outdoor Reset Setup
- Day / Night Setback
- Day / Week Setback
- Week / Year Setback
11Outdoor Reset / Setback Temp.
- Easily Configured
- Normal Setpoints
- Setback Setpoints
- High Low Limits
- Outdoor Cutoff
- Automatic Graphical Representation
12EXPANDABLE
- PWC Front Door Open
- (2 to 5 boiler lead / lag configuration shown
with three spare slots)
13CPU Board
- (2) Analog Inputs
- (4-20 mAdc /Thermistor)
- (1) Relay Output (SPDT, 8A)
- (1) RS232 programming Port
- (1) Isolated RS485 Port
- (Modbus or Bacnet Option)
- (1) Telephone Modem Option Card
- Dial in or dial out, 33.6 kb, RJ-11 jack, Data
and Pagers - (1) Printer Port (Alarms / Logs)
14Discrete Input
- (15) Inputs, 120 Vac, optically isolated
- (5) groups of isolated neutrals
- (15) LED status indications
- (2) 2A / 120 Vac Fuses
15Hand-Off-Auto Relay Output
- (5) Relay Outputs
- (8A inductive, 1/2 Hp, 120 Vac)
- (5) Hand-Off-Auto Toggle Switches
- Toggle Switch is directly wired into output
circuit. - (5) LED's for Output ON / OFF
- (5) LED's for Call for Operation
- (2) 2A / 120 Vac Fuses
16Auto/Manual Analog Output
- (5) Modulating Analog Outputs
- (5) Auto-Manual Toggle Switches
- "Manual" hardware overrides CPU
- Bumpless Manual to Auto Transfer
- (5) 0-100 Output Control Knobs
- (5) 0-100 Output Bargraphs
- Requires (1) Output Card per active channel, Any
combination of 4-20 mA and 135 ohm cards
17Analog Input
- (8) UNIVERSAL Inputs
- Switch Selectable as
- 2 wire 4-20 mA, with internal 24 Vdc
- Thermistor, -60F - 300 F
- Thermocouple, Type J, 0 - 1200 F,
- 0-5 Vdc, potentiometers and other signals
- Pulse, 0.6 ppm - 4000 Hz, 0-15 Vdc pulsers for
Oil, Gas, Water, kWh meters - Enables Fuel Budget Fuel Consumption Tracking
- (8) LED status indications
- Power Ouputs and Signal Inputs are short circuit
protected
18Relay Output
- (8) Isolated Relay Outputs
- ( 8A inductive, ½ Hp, 120 Vac)
- (2) SPDT, (6) NO-SPST
- (8) LED status indications
- (2) 2A / 120 Vac Fuses
19Communications
- To Customers
- Building Automation Systems
- (Modbus / Bacnet)
Pagers
(Modbus / Bacnet)
Diesels
Chillers etc.
Boilers
20Advanced Communication Capability
- Communications
- Modbus communication to BAS or SCADA
- Dial In From PC
- Dial Out to Alpha Numeric Pager
21Dial In From PC
22Availability
- Hard Service Manual
- Every Boiler Start / Stop Command Firing Rate
can be set manually in the unlikely event of a
CPU hardware failure or software corruption - A CPU failure will not prevent central manual
control of the boiler plant - This is a UNIQUE FEATURE!
- Fault Monitoring
- Analog Inputs (thermisters, 4-20mA signals) are
monitored LED used to show fault status
23Installation
Spare Terminals (typical)
Physical Separation Between Operation and Wiring
Screwed fast Cable Tie Downs
3/4 conduit connections
Power Fuses
24Custom Blockware
25Custom Displays
26Custom Charts
27Preferred Instruments