Title: Boiler Efficiency and Combustion Control


1
Plant Wide Controller (PWC) Overview
Preferred Instruments a division of Preferred
Utilities Mfg. Corp.
2
Plant Wide Controller
The Plant Wide ControllerTM (PWC) is a
state-of-the-art boiler sequencing, control and
monitoring system. The PWC combines innovative
ease of operation, communication and expansion
capabilities with boiler application expertise.
Off-the-shelf, standard modulating Lead-Lag
applications can be expanded to control
circulating water variable speed pumps and
isolation valves while monitoring the flame
safeguard and boiler control systems.
3
Easy to Operate
Key lockable Door Security
4
Easy to Operate
  • Hardwired Control Switches Indications

Firing Rate Control Dial
Firing Rate Auto / Man
0 - 100 Bargraph
Boiler On-Off-Auto
Status Indications
5
Easy to Operate
LCD Graphic Display and Keypad
  • Easy to use displays for
  • Boiler Plant Control Monitoring
  • Historical Trending
  • Alarm Event Handling
  • Boiler Plant Setup

6
Easy to Operate
Display Keys
  • Home Page -
  • Boiler Overview Display
  • Arrow Keys -
  • Move Cursor
  • Menu, Page Up, Down -
  • Display Selection
  • Alarm List -
  • Alarm, Event Display
  • Alarm Silence PB

7
Home Page
  • Lead / Lag Control
  • Start Qty Control
  • Sequence Control
  • Custom
  • Lead Rotate
  • Alarm Status
  • Time / Date Stamped
  • Header Status
  • Pressure / Temperature
  • Setpoint
  • Outside Temperature
  • Status
  • Started Boilers
  • Warming Boilers
  • Modulating Boilers
  • Tripped Boilers

8
Alarm Event Summary
  • Up to 200 Alarms Events
  • First in - First out
  • Operator Actions
  • Events
  • Alarms
  • Time Date Stamped

9
Historical Trending
  • An Essential Monitoring Tool
  • Multiple(4) Pen Charts
  • 8 min, 40 min., and
  • 2, 8, 24 hour charts
  • 8 channel, 2 Hr Historical Memory - Standard
  • 32 Mb Historical Memory - Optional
  • 32 ch AI 32 ch DI every 15 seconds for 30 days
  • 90 or more days for less channels with low
    activity (depends on data compression efficiency)

10
Easy Setup
  • Fill In The Blanks
  • Boiler Sequence
  • PID Tuning
  • Outdoor Reset Setup
  • Day / Night Setback
  • Day / Week Setback
  • Week / Year Setback

11
Outdoor Reset / Setback Temp.
  • Easily Configured
  • Normal Setpoints
  • Setback Setpoints
  • High Low Limits
  • Outdoor Cutoff
  • Automatic Graphical Representation

12
EXPANDABLE
  • PWC Front Door Open
  • (2 to 5 boiler lead / lag configuration shown
    with three spare slots)

13
CPU Board
  • (2) Analog Inputs
  • (4-20 mAdc /Thermistor)
  • (1) Relay Output (SPDT, 8A)
  • (1) RS232 programming Port
  • (1) Isolated RS485 Port
  • (Modbus or Bacnet Option)
  • (1) Telephone Modem Option Card
  • Dial in or dial out, 33.6 kb, RJ-11 jack, Data
    and Pagers
  • (1) Printer Port (Alarms / Logs)

14
Discrete Input
  • (15) Inputs, 120 Vac, optically isolated
  • (5) groups of isolated neutrals
  • (15) LED status indications
  • (2) 2A / 120 Vac Fuses

15
Hand-Off-Auto Relay Output
  • (5) Relay Outputs
  • (8A inductive, 1/2 Hp, 120 Vac)
  • (5) Hand-Off-Auto Toggle Switches
  • Toggle Switch is directly wired into output
    circuit.
  • (5) LED's for Output ON / OFF
  • (5) LED's for Call for Operation
  • (2) 2A / 120 Vac Fuses

16
Auto/Manual Analog Output
  • (5) Modulating Analog Outputs
  • (5) Auto-Manual Toggle Switches
  • "Manual" hardware overrides CPU
  • Bumpless Manual to Auto Transfer
  • (5) 0-100 Output Control Knobs
  • (5) 0-100 Output Bargraphs
  • Requires (1) Output Card per active channel, Any
    combination of 4-20 mA and 135 ohm cards

17
Analog Input
  • (8) UNIVERSAL Inputs
  • Switch Selectable as
  • 2 wire 4-20 mA, with internal 24 Vdc
  • Thermistor, -60F - 300 F
  • Thermocouple, Type J, 0 - 1200 F,
  • 0-5 Vdc, potentiometers and other signals
  • Pulse, 0.6 ppm - 4000 Hz, 0-15 Vdc pulsers for
    Oil, Gas, Water, kWh meters
  • Enables Fuel Budget Fuel Consumption Tracking
  • (8) LED status indications
  • Power Ouputs and Signal Inputs are short circuit
    protected

18
Relay Output
  • (8) Isolated Relay Outputs
  • ( 8A inductive, ½ Hp, 120 Vac)
  • (2) SPDT, (6) NO-SPST
  • (8) LED status indications
  • (2) 2A / 120 Vac Fuses

19
Communications
  • To Customers
  • Building Automation Systems
  • (Modbus / Bacnet)

Pagers
(Modbus / Bacnet)
Diesels
Chillers etc.
Boilers
20
Advanced Communication Capability
  • Communications
  • Modbus communication to BAS or SCADA
  • Dial In From PC
  • Dial Out to Alpha Numeric Pager

21
Dial In From PC
22
Availability
  • Hard Service Manual
  • Every Boiler Start / Stop Command Firing Rate
    can be set manually in the unlikely event of a
    CPU hardware failure or software corruption
  • A CPU failure will not prevent central manual
    control of the boiler plant
  • This is a UNIQUE FEATURE!
  • Fault Monitoring
  • Analog Inputs (thermisters, 4-20mA signals) are
    monitored LED used to show fault status

23
Installation
Spare Terminals (typical)
Physical Separation Between Operation and Wiring
Screwed fast Cable Tie Downs
3/4 conduit connections
Power Fuses
24
Custom Blockware
25
Custom Displays
26
Custom Charts
27
Preferred Instruments
Preferred Instruments 31-35 South Street
Danbury CT T (203) 743-6741 F (203)
798-7313 www.preferred-mfg.com