Transcript and Presenter's Notes

Title: GLAST Large Area Telescope:


1
GLAST Large Area Telescope Tracker
Subsystem WBS 4.1.4 2F Thermal Design Liz
Osborne Lockheed Martin Liz.Osborne_at_lmco.com
2
Agenda
  • Thermal Design Overview Requirements
  • Interface to Grid
  • Thermal Model
  • Results
  • Hot Operation, Cold Operation, Survival Minimum
  • Summary Future Work

3
Thermal Design Overview
  • Requirements (check)
  • Operating -15 to 30C
  • Survival -30 to 50C
  • 16 identical towers (25 trays each)
  • 10.2W (hot) and 8.7W (cold) per tower, located on
    MCM boards
  • Primary heat path is from MCM closeouts on each
    tray to high conductivity walls (K13), down walls
    to Grid through heatstraps
  • High emissivity external surfaces promote
    radiation between towers and to ACD

cables
4
Interface to Grid
  • Copper straps (4 per tower) conduct Q from tower
    walls to the Grid
  • Between walls and bottom tray
  • Hot 2.55W/strap
  • RTV interface at Tracker
  • Bolted (dry) at Grid
  • Interface Delta T is 3C

Tracker Walls Not Shown
Tracker interface
Copper Straps
Grid interface
5
Thermal Model
Z
  • SINDA/TSS Model
  • 82 Nodes/Tower, 1312 total
  • Trays are lumped into groups per tower
  • Top tray
  • Top 5 Standard Trays
  • Bottom 6 Standard trays
  • Heavy Trays
  • Standard No Converter trays
  • Bottom Tray
  • Each Tray Group consists of 1 Tray node, 4
    closeout nodes (Q input), 8 wall nodes
  • Copper strap interface to Grid nodes

Y
12
8
13
4
9
14
0
5
10
15
1
6
11
2
7
3
X
6
Thermal Results Hot (1 of 3)
Steady State Temperatures
C
  • Steady State Temperatures
  • Max DT up wall is 6C (7C including entire
    tower)
  • Max Temp, 24C
  • Located at Bay 5, Top 5 Std Closeout
  • Transient Temperatures
  • Max Tracker Transient, 24C

Z
Y
15
0
X
Internal View
7
Thermal Results Hot (2 of 3)
8
Thermal Results Hot (3 of 3)
Trade Grid/Tower Interface failure, center tower
(Bay 5)
C
  • DT steady state increase is 4.4C
  • Max Temp, 28.4C

Bay 4
Bay 5
Bay 6
9
Thermal Results - Cold
  • Min Tracker Transient, -3C

10
Thermal Results - Survival
  • Minimum Tracker Survival Temperature is 24 C

11
Summary Future Work
  • Summary
  • Tracker Thermal Design Presented
  • Heat conducts from MCM boards to walls, down
    walls, through copper strap interface to Grid
  • In compliance with Requirements
  • 4.4C increase with complete failure at
    Grid/Tracker interface for hottest tower
  • Future Work
  • Update thermal model as necessary
  • Tracker wall material

Requirement
In Spec
With uncertainty
Design
Margin
Operational Temperature
-15/30 C
-10/25 C
-3 /24 C
7 /1 C
Survival Temperature
-30/50 C
-25/45 C
-24/TBD C
1 heater margin/TBD C