QUIZ 1 : Sequences - PowerPoint PPT Presentation

1 / 9
About This Presentation
Title:

QUIZ 1 : Sequences

Description:

What are the correct parameters for a ... It s now time to LET Mr BENOIT HAINAULT WHO IS SENIOR technologistto present. WHAT ARE THE KEY SEQUENCES IN MSK IMAGING. – PowerPoint PPT presentation

Number of Views:146
Avg rating:3.0/5.0
Slides: 10
Provided by: afi46
Category:

less

Transcript and Presenter's Notes

Title: QUIZ 1 : Sequences


1
QUIZ 1 Sequences
2
QUIZ 1 Sequences
  • MRI technique is based on
  • Ionizing radiation imaging
  • Magnetic field and ionizing radiation combination
  • Magnetic field and radiofrequency combination
  • Magnetic field and ultrasound combination

3
QUIZ 1 Sequences
  • MRI technique is based on
  • Ionizing radiation imaging
  • Magnetic field and ionizing radiation combination
  • Magnetic field and radiofrequency combination
  • Magnetic field and ultrasound combination

4
QUIZZ Shoulder Imaging
QUIZ 1 Sequences
  • What are the correct parameters for a SE T2W Im.
  • Short TR (repetition time) and short TE (echo
    time)
  • Long TR and long TE
  • Long TR and short TE
  • Long TR, long TE and long TI (Inversion Time)

5
QUIZZ Shoulder Imaging
QUIZ 1 Sequences
  • What are the correct parameters for a SE T2W Im.
  • Short TR (repetition time) and short TE (echo
    time)
  • Long TR and long TE
  • Long TR and short TE
  • Long TR, long TE and long TI (Inversion Time)

6
QUIZ 1 Sequences
  • Between these 4 anatomies, which one appears the
    whitest (or high-signal) in SE T1 weighted
    image ?
  • CSF
  • Bone marrow
  • Muscles
  • Cortical bone

7
QUIZ 1 Sequences
  • Between these 4 anatomies, which one appears the
    whitest (or high-signal) in SE T1 weighted
    image ?
  • CSF
  • Bone marrow
  • Muscles
  • Cortical bone

8
QUIZ 1 Sequences
  • Which sequence or option do not delete the fat
    signal
  • Fat SAT (Fat SATuration, GE ) or SPIR (Spectral
    Presaturation Inversion Recovery, Philips)
  • STIR (Short Time Inversion Recovery)
  • DIXON (Philips) or IDEAL (GE)
  • SSFSE (Single Shot Fast Spin Echo, GE) or Sshot
    TSE (Single Shot Turbo Spin Echo, Philips)

9
QUIZ 1 Sequences
  • Which sequence or option do not delete the fat
    signal
  • Fat SAT (Fat SATuration, GE ) or SPIR (Spectral
    Presaturation Inversion Recovery, Philips)
  • STIR (Short Time Inversion Recovery)
  • DIXON (Philips) or IDEAL (GE)
  • SSFSE (Single Shot Fast Spin Echo, GE) or Sshot
    TSE (Single Shot Turbo Spin Echo, Philips)