Title: Accident Prevention Manual
1- Accident Prevention Manual
- for Business Industry
- Engineering Technology
- 13th edition
- National Safety Council
Compiled by Dr. S.D. Allen Iske, Associate
Professor University of Central Missouri
2CHAPTER 8
- INDUSTRIAL SANITATION AND PERSONNEL FACILITIES
3 Industrial SanitationEmployee Health and Basic
Facilities
- Issues of drinking water quality at the worksite
- Appropriate disposal of company sewage, waste and
garbage - Keeping employee facilities safe and sanitary
- Issues of nutrition and sanitation in employee
food service
4General Rules for Sanitation
- Management is responsible to provide sanitary
environment - approved water and wastewater piping and storage
system - good housekeeping
- as nature of work allows
- personal cleanliness
- routine, complete inspection system
5Drinking Water
- Facilities receive water for drinking, washing,
and food preparation from a municipal supply. - Water delivered to the facility meter must meet
- all applicable regulatory standards.
- criteria for classification as potable water
(safe for drinking and cooking)
6Drinking Water (Cont.)
- In-facility contamination
- Water arrives clean, but it doesnt stay clean
- microbiological (salmonella, giardia, hepatitis,
cryptosporidium, legionella) - chemical (mercury, benzene, lead, copper,
asbestos) - physical (discoloration, taste, turbidity)
- The most common way of contamination is by mixing
potable and nonpotable water. - Backflow is a reverse flow condition due to
differences in pressures.
7Drinking Water (Cont.)
- In-facility contamination
- Water outlets must be identified for their
specific use. - Dead-end pipes that cannot be flushed must not
exist. - Pipes containing water must be clearly marked
whether it is potable or non-potable. - No direct connections between drinking water
lines and other water systems. - Nonpotable water may be used to clean
facilities, given that it does not contain
hazardous chemicals or contamination.
8Drinking Water (Cont.)
- In-facility contamination causes
- mixing potable with nonpotable water
- actual or potential physical connection between a
potable water system and an unapproved water
supply - improper maintenance of drinking and cooking
facilities - improper installation of plumbing facilities
- Reservoirs for treated water should be completely
enclosed and located in such a way to prevent
accidental contamination.
9Plumbing
- Workers should install fixtures and faucets to
prevent back-siphonage. - Other sources of contaminations are open joints
in the underground pipes. - Codes prohibit the installation of sewer and
drinking lines in the same trench. - Contamination may occur when pipes are opened for
repair.
10Plumbing (Cont.)
- Faucets should be at least 1 in. above the
floodrim of the receptacle. - Contamination of the water supply results when a
system is opened for repair or alteration. - new pipe should be disinfected and properly
flushed with clean water - Restricted use of lead pipe, solder, flux in the
installation or repair of any public water system - U.S. Safe Drinking Water Act
11Private Water Supplies
- Built/operated under the supervision of a trained
and experienced sanitary engineer - All underground and surface waters viewed as
contaminated until proven otherwise - deep drilled well water free of biological
contamination but may be affected by minerals - shallow wells more likely to have
biological/synthetic chemical contamination - Surface sources treated with disinfectant and
filtered for potable use
12Private Water SuppliesPer-Person Water
Requirements
- 1520 gal (5575 L) drinking, lavatory, toilet
usage - 2025 gal (7595 L) per shower
- 510 gal (2040 L) per meal if food is prepared
on the premises
13Water Quality
- Organizations must evaluate their water supply
based on the contaminates it might possibly
contain. - U.S. EPA regulation establishes two sets of
standards (review Tables 8B to 8H) - primary
- secondary
- Sanitary surveillance
- determines the type of treatment and frequency of
laboratory tests of the source water and the
treated water
14Water Quality (Cont.)
- U.S. regulations established two sets of
standards relating to quality of drinking water - Primary standards are mandatory and cover all
contaminants considered health hazards. The
contaminant categories are - chemicals
- organic chemicals
- physical parameters
- microbial agents
- radioactivity
- Secondary standards are not mandatory but are
highly recommended to be followed. These
standards cover aesthetic quality of water, such
as - color
- taste
- odor
15Wells
- Drilled wells with intake below the water table
show a reliable yield and are free from bacterial
and chemical contamination. - Wellhead located as far as possible from sewage
lines, septic tanks, sewage drainage, and process
waste-disposal systems, 200 ft minimum distance. - Government and agencies require a space between
well casing and surrounding area sealed with
cement grout at a minimum depth of 10 ft below
ground or floor level. - Well installations should meet current state well
code, such as top of well casing projects at
least 12 in. above ground surface and wellhead
not covered by paving or other material to make
access difficult.
16Disinfecting Water Systems
- Water systems
- Pipes, reservoirs, standpipes, pumps, and well
casing of new systems should be disinfected. - Old systems carrying treated water for the first
time following disuse must be disinfected. - Repaired systems should be disinfected before
placing back in service. - Disinfect water by using chlorine-containing
products, ozone, or ultraviolet radiation. - Water contaminated with giardia lamblia or
cryptosporidium need other treatment such as
filtering.
17Disinfecting Water Systems (Cont.)
- Workers can disinfect water by using no less than
100 mg/l of chlorine for at least 24 hrs for new
systems, systems not previously used for treated
water, and systems that were used for treated
water but were out of service for less than 12
hrs. - Success is determined by measuring the residual
chlorine in the solution at the end of the
required time. - If there is no residual chlorine, repeat the
disinfection process. - Systems with a standpipe or reservoir should have
the solution added to the standpipe or reservoir.
18Water Purification
- Filtration
- primarily clears turbid waters
- removes some bacterial contamination
- made under competent engineering supervision and
operated under continuous inspection - Disinfection
- Chlorine is the best available disinfecting agent
for drinking water. - It is added to the water directly as a gas or as
a soluble salt.
19Water Storage
- Reservoirs and standpipes have to be enclosed
completely. - Fill vents with screened downspouts well above
floor level. - Entrance manholes should be enclosed by
watertight frames at least 6 in. higher than the
surrounding surface and fitted with covers at
least 2 in. down the outside frame. - Cover should be closed when not in use.
20Waste Disposal
- Building drains and sewers
- In-facility sewage collection systems should be
properly trapped and vented to prevent sewer
gases from entering into the building and to also
ensure proper drainage. - Traps, grease interceptors, and interceptors that
collect foreign materials should be large enough,
located for easy access, and cleaned
periodically. - Backwater valves should be installed to prevent
backup in the sewer line.
21Wastewater Disposal
- Sewage disposal systems must be constructed to
prevent contamination of water or pollution of
surface water. - All sewage systems must be properly maintained.
22Wastewater Disposal (Cont.)
- Septic tanks are buried, watertight receptacles
designed and constructed to receive wastewater - separate solids from liquids
- provide limited digestion of organic matter
- store solids
- allow the effluent (clarified liquid) to be
discharged for further treatment - Secondary treatment components may consist of
subsurface seepage field, waste oxidation lagoon,
an aerated treatment system, or another type
meeting state or local codes. - Sewage disposal systems should be located and
constructed to prevent contaminating the
groundwater or polluting the surface water. - All sewage systems must be maintained to avoid
causing a nuisance or health hazard to the
community.
23Solid Waste Disposal
- Solid waste should be collected and stored to be
picked up by a municipal or private disposal
service. - Containers should be tightly sealed to keep out
insects and rodents. - Due to the unavailability of landfill sites,
recycling programs are recommended to reduce the
amount of waste produced.
24Solid Waste Disposal (Cont.)
- Fence in any large outside garbage receptacles
and compactors. - Lock the gates to keep children out and to
prevent animals from distributing refuse. - Use tight-fitting garbage container covers to
keep out insects and rodents. - Containers should be easy to clean and handle.
- Containers should be washed periodically with a
detergent-deodorant solution.
25Refuse Collection
- Hazards in collection
- Type of equipment and conditions surrounding
operation - Frequent causes of accidents
- blades
- booby traps by companies
- loose or broken glass
- lightweight trash filled with heavy objects
- heavy objects concealed by paper and trash
- obstacles in path to refuse collection cans
- rusted or unmaintained cans for handling
- Mixing of recyclables with hazards items
26Insect, Rodent, and Nuisance Bird Control
- Should be done by professional pest-control
operators. - Poisonous chemicals should be handled by trained
personnel. - All departments should be notified in advance
about the pest-control operators visit. - Integrated Pest Management (IPM) system
- housekeeping
- maintenance
- pest-control services
27Personal Service Facilities
- Drinking fountains
- Washrooms and locker rooms
- Benches
- Floor
- Showers
- Toilets
- Janitorial Service
28Personal Service Facilities (Cont.)
- Drinking fountains
- Install one fountain for about every 50 people at
convenient places throughout an industrial
facility. - Stream projector cannot be flooded or submerged,
in case the water stream is stopped. - Have the installer direct and project the stream.
- Fountains should be covered in dusty areas.
29Personal Service Facilities (Cont.)
- Drinking fountains (cont.)
- Water temperature should be 5055F for heavy
manual labor, or 45F for less-active office work - When using portable drinking fountains
- keep the containers scrupulously clean
- sterilize daily with steam, boiling water, or
chlorine solution - do not use a common drinking cup or ladle
- drinking cups should be single-service paper
cups keep in a sanitary container at the
drinking faucet, with a receptacle provided for
disposal
30Personal Service Facilities (Cont.)
- Washing facilities
- Washing facilities should always be clean.
- Each lavatory should have hot (lt140 F) and cold
water, at least tepid running water, and liquid
hand soap or similar cleansing agent. - Circular washbasins
- permit a number of employees to wash at the same
time - easy to keep clean
- construction prevents water from splashing and
spilling
31Personal Service Facilities (Cont.)
- Washing facilities (cont.)
- 1 lavatory for every 10 employees recommended
- 1 for every 15 additional employees for more than
100 - 1 for every 5 recommended where workers need
additional washing time
32Personal Service Facilities (Cont.)
- Lockers
- perforated for ventilation
- large enough to permit clothing to be hung to dry
- have separate lockers for work clothing and
street clothing for persons working with toxic
materials that can contaminate clothing - lockers to change clothes on opposite sides of
shower room to ensure employees move through
shower to change to street clothes
33Personal Service Facilities (Cont.)
- Showers
- should be located near the work location to
prevent workers from walking long distances - must have non-slip surface
- personal cleaning agents near the shower
- provide 1 shower for every 10 employees for each
sex who are required to shower during the same
shift
34Personal Service Facilities (Cont.)
- Toilets
- Natural or forced ventilation is required for
toilet rooms. Ventilation rate should be 3 to 4
air changes per hour. - Light fixtures must be installed in all toilet
rooms and washrooms. - Toilets and urinals should be installed in a way
to allow easy sanitation of surrounding surfaces. - Employees are prohibited from eating in toilet
rooms or where toxic or noxious materials are
present. - Number provided according to the number of
employees. (Table 8I) - Be adequately supplied with toilet paper holders
in every water closet. - Provide at least 1 lavatory in the toilet room or
adjacent to it for every 3 toilet facilities. - Toilets should be only one floor above or below
the work area in multistory buildings - Ground fault circuit interrupters should be used
whenever electrical receptacles are located
within 6 ft of a sink.
35Personal Service Facilities (Cont.)
- Janitorial service
- A minimum janitorial service should be set up for
all personal service facilities. - Mop and clean floors and fixtures with detergent
and hot water at least once daily. - Use a sanitizing cleaner as often as necessary.
- Wear rubber gloves and goggles when cleaning.
- Flush the fixtures following use.
- Block off the area to prevent possible slipping
accidents when floors are wet.
36Food Services
- Nutrition
- Nutrition is an important factor in employee
health. - Proper nutrition can strengthen immunity to
diseases. - Proper meals can lessen fatigue during work, thus
reducing chances of accidents occurring.
37Food Services (Cont.)
- There are five types of industrial food service
- cafeterias, preparing and serving hot meals
- canteens or lunchrooms serving sandwiches,
packaged foods, hot and cold beverages and a few
hot foods - mobile canteens that move throughout the work
area dispensing hot and cold foods and beverages. - box-lunch service
- vending machines
38Food Services (Cont.)
- Microwaves
- equipment installation and maintenance
- eating areas
- kitchens
- controlling food contamination
39Food Services (Cont.)
- Microwave Safety
- Some food service areas have a microwave oven
nearby for quick heating of foods. Four important
safety precautions regarding microwave ovens are - Repairs should be made by manufacturer-authorized
repair personnel. - Persons with cardiac pacemakers should not come
too close to the microwave ovens. - Leakage tests should be done on a regular basis.
- Do not plug microwave ovens into extension cords.
40Food Services (Cont.)
- Kitchen
- Floors must be made of impervious,
water-resistant, easily cleaned, skid-resistant
material. - Equipment should be properly sanitized after use.
- Proper ventilation is required where food is
cooked. - Portable extinguishers and sprinkler systems
should be installed for fire protection. Fire
blankets and extinguishers should be near any
area where workers clothing could be ignited by
open flame. - Proper lighting at 20 foot-candles of light on
all food preparation surfaces and at equipment or
washing areas.
41Food Services (Cont.)
- Controlling food contamination
- Food and Drug Administration (FDA) recommends the
use of a proactive methodology. - Hazard Analysis Critical Control Points (HACCP)
system is used to identify and eliminate food
safety problems. - Effective use of the HACCP system enables one to
establish a list of critical control points.
42Food Services (Cont.)
- Foodborne illness
- Cannot be detected through taste, odor, texture
or appearance - Prevention
- Wash hands frequently during preparation and
interruptions. - Keep hot foods hot (140F or above) and cold
foods cold (40F or below). - Exclude from food preparation and handling,
personnel with wounds, infections, or
communicable diseases. - Promptly place leftover foods under
refrigeration. - Reheat leftovers quickly to 165F before serving.
- Eliminate flies, insects, and rodents from food
preparation or storage areas. - Never use galvanized or cadmium-plated containers
for storage of moist or acidic foods. - Consult the local health authority for questions
or concerns.
43Food Services (Cont.)
- Utensils
- carefully scraped and rinsed before washing
- clean with warm water containing soap
- rinse with clean water
- air dry