Accident Prevention Manual - PowerPoint PPT Presentation

1 / 43
About This Presentation
Title:

Accident Prevention Manual

Description:

There are five types of industrial food service: ... Traps, grease interceptors ... Integrated Pest Management (IPM) ... – PowerPoint PPT presentation

Number of Views:174
Avg rating:3.0/5.0
Slides: 44
Provided by: DrSD150
Category:

less

Transcript and Presenter's Notes

Title: Accident Prevention Manual


1
  • Accident Prevention Manual
  • for Business Industry
  • Engineering Technology
  • 13th edition
  • National Safety Council

Compiled by Dr. S.D. Allen Iske, Associate
Professor University of Central Missouri
2
CHAPTER 8
  • INDUSTRIAL SANITATION AND PERSONNEL FACILITIES

3
Industrial SanitationEmployee Health and Basic
Facilities
  • Issues of drinking water quality at the worksite
  • Appropriate disposal of company sewage, waste and
    garbage
  • Keeping employee facilities safe and sanitary
  • Issues of nutrition and sanitation in employee
    food service

4
General Rules for Sanitation
  • Management is responsible to provide sanitary
    environment
  • approved water and wastewater piping and storage
    system
  • good housekeeping
  • as nature of work allows
  • personal cleanliness
  • routine, complete inspection system

5
Drinking Water
  • Facilities receive water for drinking, washing,
    and food preparation from a municipal supply.
  • Water delivered to the facility meter must meet
  • all applicable regulatory standards.
  • criteria for classification as potable water
    (safe for drinking and cooking)

6
Drinking Water (Cont.)
  • In-facility contamination
  • Water arrives clean, but it doesnt stay clean
  • microbiological (salmonella, giardia, hepatitis,
    cryptosporidium, legionella)
  • chemical (mercury, benzene, lead, copper,
    asbestos)
  • physical (discoloration, taste, turbidity)
  • The most common way of contamination is by mixing
    potable and nonpotable water.
  • Backflow is a reverse flow condition due to
    differences in pressures.

7
Drinking Water (Cont.)
  • In-facility contamination
  • Water outlets must be identified for their
    specific use.
  • Dead-end pipes that cannot be flushed must not
    exist.
  • Pipes containing water must be clearly marked
    whether it is potable or non-potable.
  • No direct connections between drinking water
    lines and other water systems.
  • Nonpotable water may be used to clean
    facilities, given that it does not contain
    hazardous chemicals or contamination.

8
Drinking Water (Cont.)
  • In-facility contamination causes
  • mixing potable with nonpotable water
  • actual or potential physical connection between a
    potable water system and an unapproved water
    supply
  • improper maintenance of drinking and cooking
    facilities
  • improper installation of plumbing facilities
  • Reservoirs for treated water should be completely
    enclosed and located in such a way to prevent
    accidental contamination.

9
Plumbing
  • Workers should install fixtures and faucets to
    prevent back-siphonage.
  • Other sources of contaminations are open joints
    in the underground pipes.
  • Codes prohibit the installation of sewer and
    drinking lines in the same trench.
  • Contamination may occur when pipes are opened for
    repair.

10
Plumbing (Cont.)
  • Faucets should be at least 1 in. above the
    floodrim of the receptacle.
  • Contamination of the water supply results when a
    system is opened for repair or alteration.
  • new pipe should be disinfected and properly
    flushed with clean water
  • Restricted use of lead pipe, solder, flux in the
    installation or repair of any public water system
  • U.S. Safe Drinking Water Act

11
Private Water Supplies
  • Built/operated under the supervision of a trained
    and experienced sanitary engineer
  • All underground and surface waters viewed as
    contaminated until proven otherwise
  • deep drilled well water free of biological
    contamination but may be affected by minerals
  • shallow wells more likely to have
    biological/synthetic chemical contamination
  • Surface sources treated with disinfectant and
    filtered for potable use

12
Private Water SuppliesPer-Person Water
Requirements
  • 1520 gal (5575 L) drinking, lavatory, toilet
    usage
  • 2025 gal (7595 L) per shower
  • 510 gal (2040 L) per meal if food is prepared
    on the premises

13
Water Quality
  • Organizations must evaluate their water supply
    based on the contaminates it might possibly
    contain.
  • U.S. EPA regulation establishes two sets of
    standards (review Tables 8B to 8H)
  • primary
  • secondary
  • Sanitary surveillance
  • determines the type of treatment and frequency of
    laboratory tests of the source water and the
    treated water

14
Water Quality (Cont.)
  • U.S. regulations established two sets of
    standards relating to quality of drinking water
  • Primary standards are mandatory and cover all
    contaminants considered health hazards. The
    contaminant categories are
  • chemicals
  • organic chemicals
  • physical parameters
  • microbial agents
  • radioactivity
  • Secondary standards are not mandatory but are
    highly recommended to be followed. These
    standards cover aesthetic quality of water, such
    as
  • color
  • taste
  • odor

15
Wells
  • Drilled wells with intake below the water table
    show a reliable yield and are free from bacterial
    and chemical contamination.
  • Wellhead located as far as possible from sewage
    lines, septic tanks, sewage drainage, and process
    waste-disposal systems, 200 ft minimum distance.
  • Government and agencies require a space between
    well casing and surrounding area sealed with
    cement grout at a minimum depth of 10 ft below
    ground or floor level.
  • Well installations should meet current state well
    code, such as top of well casing projects at
    least 12 in. above ground surface and wellhead
    not covered by paving or other material to make
    access difficult.

16
Disinfecting Water Systems
  • Water systems
  • Pipes, reservoirs, standpipes, pumps, and well
    casing of new systems should be disinfected.
  • Old systems carrying treated water for the first
    time following disuse must be disinfected.
  • Repaired systems should be disinfected before
    placing back in service.
  • Disinfect water by using chlorine-containing
    products, ozone, or ultraviolet radiation.
  • Water contaminated with giardia lamblia or
    cryptosporidium need other treatment such as
    filtering.

17
Disinfecting Water Systems (Cont.)
  • Workers can disinfect water by using no less than
    100 mg/l of chlorine for at least 24 hrs for new
    systems, systems not previously used for treated
    water, and systems that were used for treated
    water but were out of service for less than 12
    hrs.
  • Success is determined by measuring the residual
    chlorine in the solution at the end of the
    required time.
  • If there is no residual chlorine, repeat the
    disinfection process.
  • Systems with a standpipe or reservoir should have
    the solution added to the standpipe or reservoir.

18
Water Purification
  • Filtration
  • primarily clears turbid waters
  • removes some bacterial contamination
  • made under competent engineering supervision and
    operated under continuous inspection
  • Disinfection
  • Chlorine is the best available disinfecting agent
    for drinking water.
  • It is added to the water directly as a gas or as
    a soluble salt.

19
Water Storage
  • Reservoirs and standpipes have to be enclosed
    completely.
  • Fill vents with screened downspouts well above
    floor level.
  • Entrance manholes should be enclosed by
    watertight frames at least 6 in. higher than the
    surrounding surface and fitted with covers at
    least 2 in. down the outside frame.
  • Cover should be closed when not in use.

20
Waste Disposal
  • Building drains and sewers
  • In-facility sewage collection systems should be
    properly trapped and vented to prevent sewer
    gases from entering into the building and to also
    ensure proper drainage.
  • Traps, grease interceptors, and interceptors that
    collect foreign materials should be large enough,
    located for easy access, and cleaned
    periodically.
  • Backwater valves should be installed to prevent
    backup in the sewer line.

21
Wastewater Disposal
  • Sewage disposal systems must be constructed to
    prevent contamination of water or pollution of
    surface water.
  • All sewage systems must be properly maintained.

22
Wastewater Disposal (Cont.)
  • Septic tanks are buried, watertight receptacles
    designed and constructed to receive wastewater
  • separate solids from liquids
  • provide limited digestion of organic matter
  • store solids
  • allow the effluent (clarified liquid) to be
    discharged for further treatment
  • Secondary treatment components may consist of
    subsurface seepage field, waste oxidation lagoon,
    an aerated treatment system, or another type
    meeting state or local codes.
  • Sewage disposal systems should be located and
    constructed to prevent contaminating the
    groundwater or polluting the surface water.
  • All sewage systems must be maintained to avoid
    causing a nuisance or health hazard to the
    community.

23
Solid Waste Disposal
  • Solid waste should be collected and stored to be
    picked up by a municipal or private disposal
    service.
  • Containers should be tightly sealed to keep out
    insects and rodents.
  • Due to the unavailability of landfill sites,
    recycling programs are recommended to reduce the
    amount of waste produced.

24
Solid Waste Disposal (Cont.)
  • Fence in any large outside garbage receptacles
    and compactors.
  • Lock the gates to keep children out and to
    prevent animals from distributing refuse.
  • Use tight-fitting garbage container covers to
    keep out insects and rodents.
  • Containers should be easy to clean and handle.
  • Containers should be washed periodically with a
    detergent-deodorant solution.

25
Refuse Collection
  • Hazards in collection
  • Type of equipment and conditions surrounding
    operation
  • Frequent causes of accidents
  • blades
  • booby traps by companies
  • loose or broken glass
  • lightweight trash filled with heavy objects
  • heavy objects concealed by paper and trash
  • obstacles in path to refuse collection cans
  • rusted or unmaintained cans for handling
  • Mixing of recyclables with hazards items

26
Insect, Rodent, and Nuisance Bird Control
  • Should be done by professional pest-control
    operators.
  • Poisonous chemicals should be handled by trained
    personnel.
  • All departments should be notified in advance
    about the pest-control operators visit.
  • Integrated Pest Management (IPM) system
  • housekeeping
  • maintenance
  • pest-control services

27
Personal Service Facilities
  • Drinking fountains
  • Washrooms and locker rooms
  • Benches
  • Floor
  • Showers
  • Toilets
  • Janitorial Service

28
Personal Service Facilities (Cont.)
  • Drinking fountains
  • Install one fountain for about every 50 people at
    convenient places throughout an industrial
    facility.
  • Stream projector cannot be flooded or submerged,
    in case the water stream is stopped.
  • Have the installer direct and project the stream.
  • Fountains should be covered in dusty areas.

29
Personal Service Facilities (Cont.)
  • Drinking fountains (cont.)
  • Water temperature should be 5055F for heavy
    manual labor, or 45F for less-active office work
  • When using portable drinking fountains
  • keep the containers scrupulously clean
  • sterilize daily with steam, boiling water, or
    chlorine solution
  • do not use a common drinking cup or ladle
  • drinking cups should be single-service paper
    cups keep in a sanitary container at the
    drinking faucet, with a receptacle provided for
    disposal

30
Personal Service Facilities (Cont.)
  • Washing facilities
  • Washing facilities should always be clean.
  • Each lavatory should have hot (lt140 F) and cold
    water, at least tepid running water, and liquid
    hand soap or similar cleansing agent.
  • Circular washbasins
  • permit a number of employees to wash at the same
    time
  • easy to keep clean
  • construction prevents water from splashing and
    spilling

31
Personal Service Facilities (Cont.)
  • Washing facilities (cont.)
  • 1 lavatory for every 10 employees recommended
  • 1 for every 15 additional employees for more than
    100
  • 1 for every 5 recommended where workers need
    additional washing time

32
Personal Service Facilities (Cont.)
  • Lockers
  • perforated for ventilation
  • large enough to permit clothing to be hung to dry
  • have separate lockers for work clothing and
    street clothing for persons working with toxic
    materials that can contaminate clothing
  • lockers to change clothes on opposite sides of
    shower room to ensure employees move through
    shower to change to street clothes

33
Personal Service Facilities (Cont.)
  • Showers
  • should be located near the work location to
    prevent workers from walking long distances
  • must have non-slip surface
  • personal cleaning agents near the shower
  • provide 1 shower for every 10 employees for each
    sex who are required to shower during the same
    shift

34
Personal Service Facilities (Cont.)
  • Toilets
  • Natural or forced ventilation is required for
    toilet rooms. Ventilation rate should be 3 to 4
    air changes per hour.
  • Light fixtures must be installed in all toilet
    rooms and washrooms.
  • Toilets and urinals should be installed in a way
    to allow easy sanitation of surrounding surfaces.
  • Employees are prohibited from eating in toilet
    rooms or where toxic or noxious materials are
    present.
  • Number provided according to the number of
    employees. (Table 8I)
  • Be adequately supplied with toilet paper holders
    in every water closet.
  • Provide at least 1 lavatory in the toilet room or
    adjacent to it for every 3 toilet facilities.
  • Toilets should be only one floor above or below
    the work area in multistory buildings
  • Ground fault circuit interrupters should be used
    whenever electrical receptacles are located
    within 6 ft of a sink.

35
Personal Service Facilities (Cont.)
  • Janitorial service
  • A minimum janitorial service should be set up for
    all personal service facilities.
  • Mop and clean floors and fixtures with detergent
    and hot water at least once daily.
  • Use a sanitizing cleaner as often as necessary.
  • Wear rubber gloves and goggles when cleaning.
  • Flush the fixtures following use.
  • Block off the area to prevent possible slipping
    accidents when floors are wet.

36
Food Services
  • Nutrition
  • Nutrition is an important factor in employee
    health.
  • Proper nutrition can strengthen immunity to
    diseases.
  • Proper meals can lessen fatigue during work, thus
    reducing chances of accidents occurring.

37
Food Services (Cont.)
  • There are five types of industrial food service
  • cafeterias, preparing and serving hot meals
  • canteens or lunchrooms serving sandwiches,
    packaged foods, hot and cold beverages and a few
    hot foods
  • mobile canteens that move throughout the work
    area dispensing hot and cold foods and beverages.
  • box-lunch service
  • vending machines

38
Food Services (Cont.)
  • Microwaves
  • equipment installation and maintenance
  • eating areas
  • kitchens
  • controlling food contamination

39
Food Services (Cont.)
  • Microwave Safety
  • Some food service areas have a microwave oven
    nearby for quick heating of foods. Four important
    safety precautions regarding microwave ovens are
  • Repairs should be made by manufacturer-authorized
    repair personnel.
  • Persons with cardiac pacemakers should not come
    too close to the microwave ovens.
  • Leakage tests should be done on a regular basis.
  • Do not plug microwave ovens into extension cords.

40
Food Services (Cont.)
  • Kitchen
  • Floors must be made of impervious,
    water-resistant, easily cleaned, skid-resistant
    material.
  • Equipment should be properly sanitized after use.
  • Proper ventilation is required where food is
    cooked.
  • Portable extinguishers and sprinkler systems
    should be installed for fire protection. Fire
    blankets and extinguishers should be near any
    area where workers clothing could be ignited by
    open flame.
  • Proper lighting at 20 foot-candles of light on
    all food preparation surfaces and at equipment or
    washing areas.

41
Food Services (Cont.)
  • Controlling food contamination
  • Food and Drug Administration (FDA) recommends the
    use of a proactive methodology.
  • Hazard Analysis Critical Control Points (HACCP)
    system is used to identify and eliminate food
    safety problems.
  • Effective use of the HACCP system enables one to
    establish a list of critical control points.

42
Food Services (Cont.)
  • Foodborne illness
  • Cannot be detected through taste, odor, texture
    or appearance
  • Prevention
  • Wash hands frequently during preparation and
    interruptions.
  • Keep hot foods hot (140F or above) and cold
    foods cold (40F or below).
  • Exclude from food preparation and handling,
    personnel with wounds, infections, or
    communicable diseases.
  • Promptly place leftover foods under
    refrigeration.
  • Reheat leftovers quickly to 165F before serving.
  • Eliminate flies, insects, and rodents from food
    preparation or storage areas.
  • Never use galvanized or cadmium-plated containers
    for storage of moist or acidic foods.
  • Consult the local health authority for questions
    or concerns.

43
Food Services (Cont.)
  • Utensils
  • carefully scraped and rinsed before washing
  • clean with warm water containing soap
  • rinse with clean water
  • air dry
Write a Comment
User Comments (0)
About PowerShow.com