Title: Abbott Point of Care
1Abbott Point of Care
- Precision Web and PCx glucose meters
- Jackie Van der Kant
- Abbott Point of Care Sales Specialist
- Steve Tait
- Implementation Specialist
- Presented to Canadian Coalition for Quality
Laboratory Medicine - May 14, 2007
2Precision PCx
Easy-to-use Customizable for valid operator ID,
patient ID, QC pass/fail, and comment
code. Advanced technology Latest generation
biosensor technology glucose-specific chemistry
minimizes interference requires no internal
cleaning for maximized infection
control Seamless connectivity Automated,
hands-free, bi-directional communication with the
laboratory via web-based POC connectivity and
data management system
3MediSense Bio-Sensor History
- No cleaning
- No wiping
- 10uL sample size
- Fast (30 secs)
- Interference compensation
- 20-second test
- Small sample size
- 5uL sample size
- Reapplication feature
- Strip to Finger convenience
- Smaller sample size
- 3.5uL sample size
- Broad Hct Range (20 to 70)
- Neonatal Claim
- Smaller sample size
- 2.5uL sample size
- Dual Fill
- GDH-NAD
- Unique Fill TriggerElectrode
- Neonatal Claim
4Precision PCx strips available
5Precision PCx Blood Glucose Test
Strip Comparison Grid
6- Integrated barcode scanning of patient, operator
and strip lot helps reduce risk of manual data
entry errors. - Improves compliance of operators
- No subjective calibration step required
- Automated lockout features help enforce
point-of-care QC standards.
Virtually eliminates data entry errors
7- Each Precision PCx Plus glucose test strip
package is barcode labeled - Calibration, lot number, expiration date,
expected quality control ranges and date of
manufacture - Benefits
- Protected strip integrity for patient safety
- Ease of use for nursing
- Enhanced laboratory compliance
- Reduced medical errors
8TrueMeasure Technology
- Abbott utilizes GDH-NAD enzyme
- GDH-NAD is not affected by elevated levels of
many interfering substances, more specific to
glucose - Acetaminophen, ascorbic acid, uric acid (kidney
disease), and gentisic acid have been shown, at
higher levels, to cause falsely elevated results
in other biosensors - Safe and effective glucose monitoring for
patients on Extraneal
9Precision PCx Plus Test Strips
Semi-opaque strip coverIncreases Confidence!
2.5 uL sampleSmallest Sample Volume!
Auto-startFast Results in 20 Seconds!No Visual
Inspection Required!
Glucose-specific chemistryLess Interference!
30 Seconds for second dropReduces Strip Waste!
Dual fill stripGreater Ease-of-use!
10Precision PCx Plus White Paper Data
11(No Transcript)
12(No Transcript)
13(No Transcript)
14PCx Plus Test Strips consistently showed good
performance in new studies of neonates testing
15(No Transcript)
16Precision Web- A Totally Integrated System
17Easy to Use and Powerful User Interface
System Tree
- Used for all system navigation
- Totally customizable
- Control what locations users see
- Drag and drop functionality
- Easily expand or contract search scope
18Precision Web Dashboard
19Acknowledge Alarms
20Best in Class Compliance Reports
- 23 pre-defined reports- Designed by POC
Coordinators - Fully customizable report suites- set your
report preferences and store them - Reports viewable on-screen or delivered
electronically in a variety of file types - Crystal Reports you develop can be added
seamlessly into the system
21Report samples
22(No Transcript)
23(No Transcript)
24Manage Lots numbers
25Easy to Use and Powerful User Interface
263rd Party Manufacturers We Have Integrated to Date
If your vendor is not listed- an interface can be
created.
27Point-of-Care Nurse Competency Trainer (NCT)
- Coming Soon!
- Web-based training tool
- POCC spend 4060 of the work week managing
operators - NCT automates operator recertification
- Paperless! NCT seamlessly updates operator
credentials in Precision Web
Easy Touch Screen Application
28Easy to Use and Powerful User Interface
Search
Sort
Analyze
Share
In Real-time to achieve Faster Corrective
Action Reduction in Paperwork Process
Improvement A Better POC Program!
29Precision Web
Multi-facility Connectivity and Compliance
- Securely link departments and facilities across
an entire health system. - Dramatically simplifies POCT data sharing and
collaboration. - Allows integration of one or more laboratory
information systems (LIS). - Users can only access information, functions and
facilities for which they are authorized. - Permits integration with virtually any
point-of-care device, regardless of manufacturer.
- Enables facilities to monitor compliance to their
Provincial guidelines and facility protocols.
30Technical Support
- Support on Abbott PCx meters and Precision Web
software, including Sybase interfaces - 1-800-387-8378
- Available 24/7
- email pocsupport_at_abbott.com
31Thank you from Abbott Point of Care
- Jackie Van der Kant
- APOC Sales Specialist
- 1-800-387-8378 x 3510
- jackie.vanderkant_at_abbott.com
- Steve Tait
- APOC Implementation Specialist
- 1-800-387-8378 x 3279
- steve.tait_at_abbott.com
- Adrienne MacDonald
- APOC Commercial Manager, Canada
- 1-800-387-8378 x 3255
- adrienne.macdonald_at_abbott.com