Title: Oasis
1Make your premises an Oasis of security
Oasis_EN_1010_c1
2A solution for your security comfort...
3Oasis is a wireless kit
Sirens
RFID cards
Keypads
Control Panel
4Wireless detectors
Motion detection
Fire Gas
Glass-break detectors
Temperature
Window, door opening..
5Wireless buttons
Wall-mount button
Door bell
Panic
Wireless relay
Key-fob
6Basic features
- 50 addresses for wireless devices (detectors, RC,
keypads and sirens) - 50 positions for user codes or/and proxy cards
- 4 wired inputs in the control panel ( plus inputs
in keypad and detectors) - (additional 10 inputs via JA-82C module)
- Lithium batteries calculated lifetime 3 years
- 868 MHz operating frequency
- Grade 2 by the EN 50131 standard (medium risk)
7JK- 82 Kit
- Set-up your system from individual items
- or
- just use the starter kit..
8JK-82 consists of
- Control panel with GSM communicator
- Wireless keypad
- PIR detector
- Magnetic detector
- Indoor siren
- Key fob
- Wireless door bell button
- Proximity card
- Accessories (batteries etc.)
9Kit installation
6
5
1
4
7
3
2
10Service mode after powering up
- A Enrollment of more devices
- key 1 and connect batteries, exit with
- B Communication quality test
- key 298 (turns on signal measurement)
- arrow keys scroll devices
- device triggering signal from 1/4 to 4/4
- returns you to Service mode
- C GSM signal strength test
- key 922
- return to Service mode by
-
- Each signal should be at least 2/4
11Service mode after powering up
- A Enrollment of more devices
- By keying in production code (on keypad or
computer) - By enrollment
- Press 1 to open enrollment (08080 for the
service mode) - Scroll to desired position
- Insert battery to enroll the item
- Erase the position by holding key 2 in
enrollment - Enrollment can also be opened by shorting the
reset pins
12Optional antennas
- AN-80
- AN-81
- Can be used with control panel and UC-82 receiver
13JA-80Z Repeater
- Repeats RF signals of up to 40 enrolled items
- Working range can be enhanced up to 2x
- Shows signal strength of enrolled items
- Hardware of JA-82K JA-82R
- Two-way communication with the control panel-
copy PGX, PGY, EW, IW outputs - Hardwired inputs TMP, INP
- JA-80F, JA-84P, JA-80A cannot be enrolled
14Wireless communication
- Robust protocol reliability
- Integrity check Supervision
- Code grabbing protection- Floating code
- Code searching protection - Antiscan
- Anti-jamming protection
- Anti-collision protection
- Diagnostics to see communication quality
15Programming
- After power-up first set language of the keypad
and communicator - Set other parameters - example
98101 EN communicator language 4 hh mm DD MM RR
clock 201 Exit delay 10sec. 811phone num0
phone number The best way is to use Olink SW
16299 enrollment of PGX to AC relay X 237 PGX
function on / off
17Handover to the user
- Explain the basics (less more)
- Always recheck that user understands
?
?
18Operating a key-fob
SET (arm)
UNSET (disarm)
Both buttons PANIC
19Keypad layout
Alarm or fault SET A, B and C Power
Details
Setting (arming) Hot keys A, B C
PGX On / Off
Detail reading
20Let the user feel that (s)he is the master
-
- Master card enrollment
- 5 1234 card
- Access card enrollment
- 6, Master card, key nn, card
- Access code programming
- 6, Master card, key nn, code
- To erase access code and card
- 6, Master card, key nn, 0000
- nn user number 01 to 50
- Each user can have code, card or both
John 2375
21Keypad operation
22 instructions
232 level partial arming
Example Family house
Garage,...
Set (armed) by
Key A
Garage Ground floor
A
Key B
A
B
Complete arming
C
C
Key ABC
A
B
A
B
24Split system
Example Two families in a house, two offices..
Brown ARMED
Set (armed) by
A
B
Code or card Brown
C
Ward ARMED
Code or card Ward
A
B
C
Entire house armed incl. Common section
If both AB armed, then C also armed
A
B
C
25Communicator test
Both buttons Panic
Panic alarm SMS
- Function test
- Knowing the SIM card tel. number
26Remote access
SMS instructions CODE space INSTRUCTION
- Phone call
- Call and wait for the system to respond (after 5
rings) - Enter a valid code (master, user or service)
- Operate the system hang up at the end
27The JA-82K control panel
- Modularity
- JA-82K control panel 4 inputs
- JA-82R radio
- JA-82C 10 inputs
- 50 addresses for devices
- Wired inputs
- Wireless devices
- Enrollment via radio comm. or
- by keying in production codes
- 50 addresses for codes / cards
- Optional code card configuration
- Mains power supply and battery
- Output 12V, 500mA
- Memory for the last 255 events
- Replaceable memory chip
- Alarm outputs EW and IW
- Programmable outputs PgX and PgY
28The JA-83K control panel
JA-82R radio module
Power transformer 1.1 A
antenna
Up to 30 wired inputs
- Communicator
- 80X telephone line
- 80Y GSM
- 80V LAN tel. line
Back up battery up to 18 Ah
29Hard-wired inputs
Hard-wired inputs addresses 01 to 14 / 30 (can be
switched off by DIP switch or by SW) Maximum of 5
detectors in a loop Double balanced - triggering
and tampering Programmable reaction (Natural
delayed) Enrollment of a wireless device to
address 01 - 14 disables the input terminal
Connected to COM via a 1 k? resistor
untriggered input Connected to COM via 2 to 5
k? triggered input, Connected to COM via less
then 700? or more then 7k8 k? tamper signal
30Control panel reactions
- Devices and codes/cards can have reactions
- Off
- NATURAL (key-fob, code and card set / unset,
smoke detector fire alarm) - 24 hours
- Instant
- Delay (Natural)
- Next delay
- Fire
- Panic
- Set
- Set / Unset
- PG control
- Every device, input, code and card can be
assigned to section A, B or C
Pepa 6319 Láda 1507 Mána 389
John 6319 David 1507 Peter 389
31OLink SW
- Example of system management
32Device setting
33Code and card setting
34Control panel setting
35The JA-81F keypad
- Fully graphical display
- Customizable logo (128x48)
- Two versions
- White backlight only
- Settable backlight color JA-81F-RGB
- Wakening by
- External input
- Gently pressing the keypads door
- Internal menu
- Language setting
- Brightness
- Contrast
- Backlight color (JA-81F-RGB only)
- Text editing
- Manually or via Olink software
- JA-82T direct connection support
- JA-81E hard-wired version
36The PC-01 proximity cards
- RFID access card (EM UNIQUE 125kHz)
- Up to 50 cards can be enrolled to the system
- The card has the same function as an access code
- For higher security the card can be combined with
a code - PC-02, PC-0x
37The JA-80H outdoor keypad
- Built in RFID reader
- Connects to the control panel bus via WJ-80
- Provides a doorbell button
- Illuminated keys
- IP-65
- Standby consumption 45 mA
38The JA-80N outdoor reader
- RFID card reader
- Connects to the control panel bus via WJ-80
- IP-65
- Standby consumption 40 mA
39The WJ-80 interface
- Connects outdoor keypad (reader) to the control
panel - Built-in door bell transmitter (for JA-80L)
- Output to operate an electrical door lock
(Z8-12V) - Provides output to operate the electric strike of
an electrical door lock an open button input - Keypad uses Wiegand protocol 26b
- DIP switches
- System keypad / Outdoor bypass switch
- PGY can operate the door lock as well (Y/N)
- Door lock activation time 3 / 6 seconds
- Exit entrance beeps (Y/N)
Sequence 248 PGY pulse Authorized phone
opening 777 775 0229 To program 81 1 777 775 022
790
Control panel bus
40Wireless detectors
- Powered by lithium batteries
- Battery lifetime is up to 3 years (status is
supervised) - Communication range about 200 300m open area
- Communication supervision every 9 minutes
- Detection of motion, glass-breaking, opening,
smoke, heat, gas
41The JA-80P motion detector
- PIR sensor
- Hard-wired input IN (initiates same reaction as
PIR) - 15 min test mode after closing the cover
- 5 min sleep time (can be shortened to 1 minute)
- DIP switches
- DEL / INS (Natural reaction)
- NORM / HIGH (immunity level)
- Covers 120 / 12m
- Optional lenses (pet, long corridor, vertical
curtain) - 1 x AA Lithium battery 3.6V
42The JA-83P mini motion detector
- PIR detector 1/3 smaller than JA-80P
- 15 min test mode after closing the cover
- 5 min sleep time (can be shortened to 1 minute)
- DIP switches
- DEL / INS (Natural reaction)
- NORM / HIGH (immunity level)
- Covers 120 / 12m
- Optional lenses (pet, long corridor, vertical
curtain) - 1x CR123A Lithium battery 3V
43The JA-86P dual-zone detector
- Dual PIR sensor resolves PET problems
- Usable in extreme environment (cellar mice,
insects) - Indoor use only
- 15 min test mode after closing the cover
- 5 min sleep time (can be shortened to 1 minute)
- DIP switches
- DEL / INS (Natural reaction)
- NORM / HIGH (immunity level)
- 1 x AA Lithium battery 3.6V (3 year life time)
- Principle PIR1 PIR2 Alarm
- JS-22 wired version
44The JA-84P detector with built-in camera
Flash
Camera
Motion detector
45The JA-84P detector with built-in camera
USB connector
46The JA-84P detector with built-in camera
- Installation
- The JA-80Q into the control panel
- Photo transmission from the premises
- Cooperates with an 80Y (GSM) or an 80V (LAN)
communicator - Enroll the detector to the control panel
- Enroll a key-fob to the detector
- Close the detectors cover (green LED)
- Press any key on the key-fob
- Camera testing
- Set (Arm) button with flash
- Unset (Disarm) button without flash
- The key-fob is automatically erased after 15
minutes - Switch off radio interference indication
- The photos can be displayed at
- www.img.jablotron.com
Have your portrait taken.
47The JA-84P parameters
- Camera resolution 160 x 120 BW
- Bi-directional communication
- On activation takes 4 pictures
- 1x without flash
- 3x with flash
- Range of the flash max. 3 meters
- Detectors memory capacity 61 photos
- USB port
- Flash drive functionality
- Photo transfer time to server approx. 15s
- Battery 2x CR-123A
- Lifetime approx 3 years (inc. 100 photo series)
- Testing by key-fob
- 4 configuration switches
- DEL / INS (Delayed / Instant reaction)
- NORM / HIGH (PIR analysis)
- ON / OFF Flash (flash)
- ON / OFF Trans (photo transmission)
48The JA-84P detector with built-in camera
49The JA-84P detector with built-in camera
- Register at www.img.jablotron.com
50The JA-84P detector with built-in camera
- Displaying pictures on www.img.jablotron.com
51The JA-84P detector with built-in camera
Configuration
52The JA-84P detector with built-in camera
Configuration
53Picture can be sent to a mobile
- Flash forces the violator to look at the camera
- Provoking an attack
- Camera is designed to confirm the alarm
Oasis
54 ...and on top of all that
- iPhone owners can use a special application
for access to the pictures from their Oasis
system -
iPhone
Oasis
55iPhone application demo
56The JA-85P motion detector
- Mini-size PIR detector
- Can be used in a house or in the car (CA-1802
1803) - 15 min test mode after closing the cover
- DIP switches
- NORM / HIGH (immunity level)
- DEL / INS (Natural reaction)
- Supervision ON / OFF
- Sleep 1 / 5 minutes
- Semi-sphere lens max. detection distance 5m
- 1 x AA Lithium 3.6V battery
57The JA-85B glass-break detector
- Dual detection (air pressure change glass
breaking sound) - Can be used in the house or in the car
- 15 min test mode after closing the cover
- DIP switches
- DEL / INS (Natural reaction)
- Supervision ON / OFF
- Detection up to 9 meters (min. 0,6 x 0,6 m)
- Can be tested with GBT-212
- 1 x AA Lithium 3.6V battery
58The JA-80PB motion and glass-break
- PIR sensor glass-break sensor in one housing
- Enrolls to 2 addresses in the system
- The same characteristics as JA-80P with JA-85B
- Glass-break DIP switches
- DEL / INS (Natural reaction)
- PIR / GBS (LED indicator function in test mode)
- 2 Lithium bateries 1 x AA 1x 1/2 AA 3,6V
59The JA-89P outdoor PIR detector
- Based on an Optex product
- 2 sensors (eliminate alarms caused by small
animals) - IP-54 cover
- Installation height 0.8 - 1.2 m
- Adjustable detection angle
- 1 x AA Lithium battery 3.6V
Covered area adjustable
area not covered
60The JA-81M detector
- Magnetic door / window detector
- Status detector (optional pulse reaction)
- DIP switches
- DEL / INS (Natural reaction)
- MG ON / OFF (enable/disable internal sensor)
- 3 input terminals
- TMP tamper input
- IN1 NC / NO alarm input (1k balanced)
- IN2 Roller-shutter input (3 activations within
5s alarm, disconnection tamper) - 1x AA Lithium 3.6V battery
61The JA-83M magnetic detector
- Magnetic detector about 1/3 shorter than the
JA-81M - Status detector (optional pulse reaction)
- DIP switch
- DEL / INS (Natural reaction)
- 2 types of the magnets
- Classic cube (see the picture)
- Magnetic ring with a screw
- 1x CR-123A 3V Lithium battery
62The JA-82M window detector
- Invisible window (door) detector (EURO or
wooden) - To be installed in the frame of a window (door)
- DIP switches
- INS / DEL (Natural reaction)
- TMP on / off
- Status / Pulse reporting
- 2 x CR2354 Lithium 3V battery
Back-plates
63The CT-01 roller-shutter detector
- Detects window shutter (curtain) movement
- Principle ratchet-wheel generates the pulses
- Can be used with the JA-81M
Example of the IN2 connection
64The LD-81 flood detector
- Can be connected to the JA-81M or JA-60N
- Conductivity sensor
- Protection of kitchen, bathroom, cellar
- Should not be placed permanently
- in water
65The LD-12 flood detector
- Hardwired detector
- Protection of kitchen, bathroom, cellar
- NO and NC output
- Should not be placed permanently
- in water
66The JA-80S smoke detector
- Fire detector (optical smoke temperature over
60C) - Testing by test button or by aerosol
- During alarm the siren can by stopped by pressing
its button - Jumpers
- FIRE / INS (Natural reaction, INS restaurant,
fireplace...) - SIREN ON / OFF
- 1 x AA Lithium 3,6V battery
Siren
Reaction
67The JA-80G gas detector
- Combustive gas detector (propane, methane..)
- Sensor hot platinum wire
- Mains powered
- Can be tested with a cigarette lighter
- DIP switches
- 10 / 20 LEL (gas concentration)
- MEM ON / OFF (memory function)
- Output relay contact max. 6A
68RC-8x controllers
- To be enrolled by inserting a battery or pressing
a button - Can be used with a control panel, UC and AC
receivers and indoor siren - Communication range up to 100m
Controlling, panic..
Door bell, panic..
Personal panic
Controlling, panic.. (housing for 2 or 4 buttons)
69The RC-86 key-fob
- Universal two-band key-fob
- 868MHz OASiS
- 433MHz PROFI / Maestro / Comfort
- Frequency setting is done easily just by the
buttons - Communication range 30 meters
- Housing for 2 and 4 buttons
Setting table
70The RC-88 button
- DIP switches
- Panic (remote control or panic button function)
- TMP (disable tamper sensors and communication
supervision) - Can also be used with UC, AC and JA-80L
- 1x 1/2 AA Lithium 3.6V battery
- (3 year life time, max. 20 activations/day)
71The RC-87 personal panic button
- Can be enrolled to the control panel, siren or
UC/AC modules - Optional
- Wrist watch or necklace version
- Audible confirmation of triggering
- Delay (5s) to stop accidental triggering
- No radio communication supervision
- CR2032 lithium battery
- Working range up to 200m
72The RC-85 remote control module
- Design to be installed in a car (12 to 24V)
- 3 wires
- GND
- A if connected to U transmits arming signal
- B if connected to U transmits disarming signal
- both A B connected to U transmits a panic
signal - Flashing full-beam headlights or blowing the horn
send signals - Can also be used to transmit an alarm from a car
alarm - Optional double click activation
- No battery, powered by car
73The JA-80L indoor siren
- Mains powered
- Disconnected from power during alarm tamper
alarm - Disconnected from power without alarm low-bat
warning (optional) - Enrolls by plugging in
- Selectable alarm setting following PG
outputs(alarm reporting from one section only) - Generates sounds
- IW alarm
- Exit and entrance beeps
- Door bell - 8 melodies
- Detector - triggered sounds - 8 melodies
- LED indicates PGY status
- Two volume levels (by keeping the button pressed)
- Triple click enables/disables arming chirp sounds
- Signal level measurement by pressing button
74The JA-80A outdoor siren
- Totally wire-free !!!
- Loudness 112dB / 1m (increases gradually)
- Max. duration of the siren sound 3 min.
- Flashes 30 min. after the alarm
- Jumpers
- 50 / 25 s. (communication cycle with the control
panel) - LED ON / OFF (warning flash every minute)
- Enrolls by connecting its battery
- Lithium battery BAT-80 (max. life time 3 to 5
years)
75Communicators
Position
- External communication
- GSM network GPRS, SMS, VOICE
- Internet (LAN - Ethernet)
- PSTN
- Reports from the system
- Remote access
76Event reporting
Telephone network
INTERNET
and or
Automatic Receiving Center
User notification
Oasis
77Remote access
www.GSMLink.cz
INTERNET
and or
Internet
Telephone
78The JA-80Y GSM communicator
- Communication via GSM/GPRS
- Event reporting by
- SMS (17 lang. selection)
- Phone calls
- ARC (IP, SMS or CID protocols)
- Picture transmission (using JA-80Q module)
- GSM gateway function
- Remote access via
- Phone (keypad registration or SMS)
- Internet - www.gsmlink.cz
- Unanswered ringing from an authorized phone
number - ARC programming can be locked
79The JA-80V LANPSTN communicator
- Communication via LAN PSTN
- Event reporting by
- SMS (17 lang. selection)
- phone calls
- ARC (IP, CID or DR protocols)
- Picture transmission (using JA-80Q module)
- Remote access via
- Phone (keypad registration or SMS)
- Internet - www.gsmlink.cz
- Unanswered ringing from an authorized phone
number - ARC programming can be locked
80GSMLink
- Remote access by Internet
www.GSMLink.cz
811. Register at www.GSMLink.cz
82Configuration page example
83The JA-80X voice communicator
- Reports alarms with voice messages
- Up to 4 phone numbers via PSTN
- 7 voice messages
- System name
- Intrusion
- Fire
- Tampering
- Panic
- Technical alarm
- Remote access welcome note
- Allows remote access via telephone keypad
authorization (DTMF) - Supports CID protocol transmission to ARC (PSTN
line) - Can be combined with JA-80V or JA-80Y
84The SP-02 speaker phone
- Can be connected to PSTN or to the phone line
simulated by JA-80Y - For listening in and talking
- Answers calls from authorized numbers
- Up to 8 phone numbers can be authorized
- Push-to-talk feature to call an emergency number
- Half-duplex communication allows a high
sensitivity for listening - 2 x AA alkaline 1.5V battery
85The JA-68 output module
- For control panels of the 6x and 8x series
- 8 galvanically-separated outputs
- 9 terminals
- C - Common
- A - Set (Armed)
- I - Intrusion
- F - Fire
- S - Tamper (Sabotage)
- P - Panic
- T - Fault
- AC Mains dropout
- LB Low Battery
- Selectable NC or NO logic using a jumper
- 12V and GND terminals power supply output,
max. 100mA - Can be used in combination with a communicator
- Designed as a general purpose device
- Suitable e.g. for ARC radio communicators
86The UC-82 relay module
- Powered by 12V DC
- 2 output relays (X Y) - max 2A
- Low bat. output
- External antenna is optional
- Powered by 12V (20mA) external source
- Can be used with
- Control panel
- Detectors
- RC-8x transmitters
87The AC-82 relay module
- Powered directly from mains 230V, 50Hz
- 2 output relays (X and Y) - max 5A
- Can be used with
- Control panel
- Detectors
- RC-8x transmitters
- TP-8x thermostats
88The TP-8x thermostats
- TP-82
- Regulated temperature adjust.
- Temperature measurement
- Lockable
- Adjustable
- Hysteresis
- Operational limits
- Sensor correction
- Alarm thresholds
- TP-83
- Weekly program
- Day/night temperature for every hour
- Day temperature increase by 2C
- Programme display
- Adjustable
- Hysteresis
- Operational limits
- Sensor correction
- Alarm thresholds
- Adaptive switch-on
- AC-83
- Receiver
- Mains powered
- 3 relays
- Heating circuit 1
- Heating circuit 2
- Pump
- Pump cleaning
- Remote control of the heating
- Common functions
- AA 1.5V alkaline battery
- Remote control via the control panel
- Incl. antifreeze functions
- Heating disabling when window is open
- Freeze alarm
- Fire alarm
89The TP-8xIR thermostat
- Wirelessly measures the floor temperature E by
the IR sensor - Accurate comfortable regulation
- TP-82IR, TP-83IR versions available
- Two additional temperature settings
- Minimal floor temperature
- Maximal floor temperature
90Smart heating system
Remote controls
Window detectors
Control panel
Thermostat
AC-82
Remote access and status information
Telephone
Heating
Operating the heating by windows CLOSED normal
heating OPEN anti freezing heating only
91The JA-82T and JA-80BT interfaces
- Connects control panel to PC
- Provides USB or Bluetooth interface
- Suitable for O-link, Comlink software
92Something more
93The GD-04 David GSM module
PC connection cable and GD-Link software
Backup module
DTMF module
Main unit
Power adapter
Radio module
Building-block-like modularity
94GD-04 David features
- Relay operation via a mobile phone
- SMS instructions (of the type ON or OFF)
- Instruction text can be edited
- Maximum text length is 30 characters
- SMS reports can be sent to inform about relay
operation - Dialling-in from an authorized phone
- Up to 50 tel. numbers can be programmed for each
relay. - The switch-on period after dialling-in is
configurable in the range of 1s to 10 hours - Each tel. number can have a limit to the number
of calls (useful e.g. at parking-lots)
95GD-04 David features
- SMS reports on input activation
- Each of the A to D inputs can have its
activation/deactivation reported - Up to 8 tel. numbers can be programmed for each
input. - Maximum report text length is 30 characters.
- SMS reports can be emphasized by subsequent phone
calls. - Device input state can be interrogated
- By the SMS instruction STATUS (editable)
96GD-04 David programming
- Via a mobile phone using SMS instructions
- Only 8 instructions (texts, numbers, other
functions) - An instruction starts with an access code ( PC
by factory default) - Multiple instructions in a single SMS (usually,
only one SMS is needed to program the whole
configuration) - Using a PC running GD-Link software
- A CD and a USB connection cable
- supplied with the package
- Via the Jablotron web page
- Fill-in a form
- Send it
- You get an SMS reply (PROGRAM OK)
- Free of charge, no registration needed
Simple and elegant.....
97News on the car alarm product range
98CA-1803 BT ATHOS
- Car protection
- Reporting of alarms by SMS or phone calls
- Remote immobilization via SMS instructions
- Garage protection using wireless JA-8x detectors
- Listening-in to the car using an HF-03
- hands free set optional
- Remote control key-fob, phone or the Internet
- Logistics support
- Car navigation via a Bluetooth connection to a
PDA or to a mobile phone - Monitoring car use (location) via the Internet
(suitable for monitoring work journeys) - Additional features
- Operating car appliances
- Hands-free calling from the car using an HF-03
- ARC supervision
99GSMLink car location monitoring