Oasis - PowerPoint PPT Presentation

1 / 99
About This Presentation
Title:

Oasis

Description:

Oasis – PowerPoint PPT presentation

Number of Views:1572
Avg rating:3.0/5.0
Slides: 100
Provided by: dali153
Category:
Tags: ee | oasis

less

Transcript and Presenter's Notes

Title: Oasis


1
Make your premises an Oasis of security
Oasis_EN_1010_c1
2
A solution for your security comfort...
3
Oasis is a wireless kit
Sirens
RFID cards
Keypads
Control Panel
4
Wireless detectors
Motion detection
Fire Gas
Glass-break detectors
Temperature
Window, door opening..
5
Wireless buttons
Wall-mount button
Door bell
Panic
Wireless relay
Key-fob
6
Basic features
  • 50 addresses for wireless devices (detectors, RC,
    keypads and sirens)
  • 50 positions for user codes or/and proxy cards
  • 4 wired inputs in the control panel ( plus inputs
    in keypad and detectors)
  • (additional 10 inputs via JA-82C module)
  • Lithium batteries calculated lifetime 3 years
  • 868 MHz operating frequency
  • Grade 2 by the EN 50131 standard (medium risk)

7
JK- 82 Kit
  • Set-up your system from individual items
  • or
  • just use the starter kit..

8
JK-82 consists of
  • Control panel with GSM communicator
  • Wireless keypad
  • PIR detector
  • Magnetic detector
  • Indoor siren
  • Key fob
  • Wireless door bell button
  • Proximity card
  • Accessories (batteries etc.)

9
Kit installation
6
5
1
4
7
3
2
10
Service mode after powering up
  • A Enrollment of more devices
  • key 1 and connect batteries, exit with
  • B Communication quality test
  • key 298 (turns on signal measurement)
  • arrow keys scroll devices
  • device triggering signal from 1/4 to 4/4
  • returns you to Service mode
  • C GSM signal strength test
  • key 922
  • return to Service mode by
  • Each signal should be at least 2/4

11
Service mode after powering up
  • A Enrollment of more devices
  • By keying in production code (on keypad or
    computer)
  • By enrollment
  • Press 1 to open enrollment (08080 for the
    service mode)
  • Scroll to desired position
  • Insert battery to enroll the item
  • Erase the position by holding key 2 in
    enrollment
  • Enrollment can also be opened by shorting the
    reset pins

12
Optional antennas
  • AN-80
  • AN-81
  • Can be used with control panel and UC-82 receiver

13
JA-80Z Repeater
  • Repeats RF signals of up to 40 enrolled items
  • Working range can be enhanced up to 2x
  • Shows signal strength of enrolled items
  • Hardware of JA-82K JA-82R
  • Two-way communication with the control panel-
    copy PGX, PGY, EW, IW outputs
  • Hardwired inputs TMP, INP
  • JA-80F, JA-84P, JA-80A cannot be enrolled

14
Wireless communication
  • Robust protocol reliability
  • Integrity check Supervision
  • Code grabbing protection- Floating code
  • Code searching protection - Antiscan
  • Anti-jamming protection
  • Anti-collision protection
  • Diagnostics to see communication quality

15
Programming
  • After power-up first set language of the keypad
    and communicator
  • Set other parameters - example

98101 EN communicator language 4 hh mm DD MM RR
clock 201 Exit delay 10sec. 811phone num0
phone number The best way is to use Olink SW
16
299 enrollment of PGX to AC relay X 237 PGX
function on / off
17
Handover to the user
  • Explain the basics (less more)
  • Always recheck that user understands

?
?
18
Operating a key-fob
SET (arm)
UNSET (disarm)
Both buttons PANIC
19
Keypad layout
Alarm or fault SET A, B and C Power
Details
Setting (arming) Hot keys A, B C
PGX On / Off
Detail reading
20
Let the user feel that (s)he is the master
  • Master card enrollment
  • 5 1234 card
  • Access card enrollment
  • 6, Master card, key nn, card
  • Access code programming
  • 6, Master card, key nn, code
  • To erase access code and card
  • 6, Master card, key nn, 0000
  • nn user number 01 to 50
  • Each user can have code, card or both

John 2375
21
Keypad operation
22
instructions
23
2 level partial arming
Example Family house
Garage,...
Set (armed) by
Key A
Garage Ground floor
A
Key B
A
B
Complete arming
C
C
Key ABC
A
B
A
B
24
Split system
Example Two families in a house, two offices..
Brown ARMED
Set (armed) by
A
B
Code or card Brown
C
Ward ARMED
Code or card Ward
A
B
C
Entire house armed incl. Common section
If both AB armed, then C also armed
A
B
C
25
Communicator test
Both buttons Panic
Panic alarm SMS
  • Function test
  • Knowing the SIM card tel. number

26
Remote access
SMS instructions CODE space INSTRUCTION
  • Phone call
  • Call and wait for the system to respond (after 5
    rings)
  • Enter a valid code (master, user or service)
  • Operate the system hang up at the end

27
The JA-82K control panel
  • Modularity
  • JA-82K control panel 4 inputs
  • JA-82R radio
  • JA-82C 10 inputs
  • 50 addresses for devices
  • Wired inputs
  • Wireless devices
  • Enrollment via radio comm. or
  • by keying in production codes
  • 50 addresses for codes / cards
  • Optional code card configuration
  • Mains power supply and battery
  • Output 12V, 500mA
  • Memory for the last 255 events
  • Replaceable memory chip
  • Alarm outputs EW and IW
  • Programmable outputs PgX and PgY

28
The JA-83K control panel
JA-82R radio module
Power transformer 1.1 A
antenna
Up to 30 wired inputs
  • Communicator
  • 80X telephone line
  • 80Y GSM
  • 80V LAN tel. line

Back up battery up to 18 Ah
29
Hard-wired inputs
Hard-wired inputs addresses 01 to 14 / 30 (can be
switched off by DIP switch or by SW) Maximum of 5
detectors in a loop Double balanced - triggering
and tampering Programmable reaction (Natural
delayed) Enrollment of a wireless device to
address 01 - 14 disables the input terminal
Connected to COM via a 1 k? resistor
 untriggered input Connected to COM via 2 to 5
k? triggered input, Connected to COM via less
then 700? or more then 7k8 k? tamper signal
30
Control panel reactions
  • Devices and codes/cards can have reactions
  • Off
  • NATURAL (key-fob, code and card set / unset,
    smoke detector fire alarm)
  • 24 hours
  • Instant
  • Delay (Natural)
  • Next delay
  • Fire
  • Panic
  • Set
  • Set / Unset
  • PG control
  • Every device, input, code and card can be
    assigned to section A, B or C

Pepa 6319 Láda 1507 Mána 389
John 6319 David 1507 Peter 389
31
OLink SW
  • Example of system management

32
Device setting
33
Code and card setting
34
Control panel setting
35
The JA-81F keypad
  • Fully graphical display
  • Customizable logo (128x48)
  • Two versions
  • White backlight only
  • Settable backlight color JA-81F-RGB
  • Wakening by
  • External input
  • Gently pressing the keypads door
  • Internal menu
  • Language setting
  • Brightness
  • Contrast
  • Backlight color (JA-81F-RGB only)
  • Text editing
  • Manually or via Olink software
  • JA-82T direct connection support
  • JA-81E hard-wired version

36
The PC-01 proximity cards
  • RFID access card (EM UNIQUE 125kHz)
  • Up to 50 cards can be enrolled to the system
  • The card has the same function as an access code
  • For higher security the card can be combined with
    a code
  • PC-02, PC-0x

37
The JA-80H outdoor keypad
  • Built in RFID reader
  • Connects to the control panel bus via WJ-80
  • Provides a doorbell button
  • Illuminated keys
  • IP-65
  • Standby consumption 45 mA

38
The JA-80N outdoor reader
  • RFID card reader
  • Connects to the control panel bus via WJ-80
  • IP-65
  • Standby consumption 40 mA

39
The WJ-80 interface
  • Connects outdoor keypad (reader) to the control
    panel
  • Built-in door bell transmitter (for JA-80L)
  • Output to operate an electrical door lock
    (Z8-12V)
  • Provides output to operate the electric strike of
    an electrical door lock an open button input
  • Keypad uses Wiegand protocol 26b
  • DIP switches
  • System keypad / Outdoor bypass switch
  • PGY can operate the door lock as well (Y/N)
  • Door lock activation time 3 / 6 seconds
  • Exit entrance beeps (Y/N)

Sequence 248 PGY pulse Authorized phone
opening 777 775 0229 To program 81 1 777 775 022
790
Control panel bus
40
Wireless detectors
  • Powered by lithium batteries
  • Battery lifetime is up to 3 years (status is
    supervised)
  • Communication range about 200 300m open area
  • Communication supervision every 9 minutes
  • Detection of motion, glass-breaking, opening,
    smoke, heat, gas

41
The JA-80P motion detector
  • PIR sensor
  • Hard-wired input IN (initiates same reaction as
    PIR)
  • 15 min test mode after closing the cover
  • 5 min sleep time (can be shortened to 1 minute)
  • DIP switches
  • DEL / INS (Natural reaction)
  • NORM / HIGH (immunity level)
  • Covers 120 / 12m
  • Optional lenses (pet, long corridor, vertical
    curtain)
  • 1 x AA Lithium battery 3.6V

42
The JA-83P mini motion detector
  • PIR detector 1/3 smaller than JA-80P
  • 15 min test mode after closing the cover
  • 5 min sleep time (can be shortened to 1 minute)
  • DIP switches
  • DEL / INS (Natural reaction)
  • NORM / HIGH (immunity level)
  • Covers 120 / 12m
  • Optional lenses (pet, long corridor, vertical
    curtain)
  • 1x CR123A Lithium battery 3V

43
The JA-86P dual-zone detector
  • Dual PIR sensor resolves PET problems
  • Usable in extreme environment (cellar mice,
    insects)
  • Indoor use only
  • 15 min test mode after closing the cover
  • 5 min sleep time (can be shortened to 1 minute)
  • DIP switches
  • DEL / INS (Natural reaction)
  • NORM / HIGH (immunity level)
  • 1 x AA Lithium battery 3.6V (3 year life time)
  • Principle PIR1 PIR2 Alarm
  • JS-22 wired version

44
The JA-84P detector with built-in camera
  • 3 in 1

Flash
Camera
Motion detector
45
The JA-84P detector with built-in camera
USB connector
46
The JA-84P detector with built-in camera
  • Installation
  • The JA-80Q into the control panel
  • Photo transmission from the premises
  • Cooperates with an 80Y (GSM) or an 80V (LAN)
    communicator
  • Enroll the detector to the control panel
  • Enroll a key-fob to the detector
  • Close the detectors cover (green LED)
  • Press any key on the key-fob
  • Camera testing
  • Set (Arm) button with flash
  • Unset (Disarm) button without flash
  • The key-fob is automatically erased after 15
    minutes
  • Switch off radio interference indication
  • The photos can be displayed at
  • www.img.jablotron.com

Have your portrait taken.
47
The JA-84P parameters
  • Camera resolution 160 x 120 BW
  • Bi-directional communication
  • On activation takes 4 pictures
  • 1x without flash
  • 3x with flash
  • Range of the flash max. 3 meters
  • Detectors memory capacity 61 photos
  • USB port
  • Flash drive functionality
  • Photo transfer time to server approx. 15s
  • Battery 2x CR-123A
  • Lifetime approx 3 years (inc. 100 photo series)
  • Testing by key-fob
  • 4 configuration switches
  • DEL / INS (Delayed / Instant reaction)
  • NORM / HIGH (PIR analysis)
  • ON / OFF Flash (flash)
  • ON / OFF Trans (photo transmission)

48
The JA-84P detector with built-in camera
  • Detector coverage

49
The JA-84P detector with built-in camera
  • Register at www.img.jablotron.com

50
The JA-84P detector with built-in camera
  • Displaying pictures on www.img.jablotron.com

51
The JA-84P detector with built-in camera
Configuration
52
The JA-84P detector with built-in camera
Configuration
53
Picture can be sent to a mobile
  • Flash forces the violator to look at the camera
  • Provoking an attack
  • Camera is designed to confirm the alarm

Oasis
54
...and on top of all that
  • iPhone owners can use a special application
    for access to the pictures from their Oasis
    system

iPhone
Oasis
55
iPhone application demo
56
The JA-85P motion detector
  • Mini-size PIR detector
  • Can be used in a house or in the car (CA-1802
    1803)
  • 15 min test mode after closing the cover
  • DIP switches
  • NORM / HIGH (immunity level)
  • DEL / INS (Natural reaction)
  • Supervision ON / OFF
  • Sleep 1 / 5 minutes
  • Semi-sphere lens max. detection distance 5m
  • 1 x AA Lithium 3.6V battery

57
The JA-85B glass-break detector
  • Dual detection (air pressure change glass
    breaking sound)
  • Can be used in the house or in the car
  • 15 min test mode after closing the cover
  • DIP switches
  • DEL / INS (Natural reaction)
  • Supervision ON / OFF
  • Detection up to 9 meters (min. 0,6 x 0,6 m)
  • Can be tested with GBT-212
  • 1 x AA Lithium 3.6V battery

58
The JA-80PB motion and glass-break
  • PIR sensor glass-break sensor in one housing
  • Enrolls to 2 addresses in the system
  • The same characteristics as JA-80P with JA-85B
  • Glass-break DIP switches
  • DEL / INS (Natural reaction)
  • PIR / GBS (LED indicator function in test mode)
  • 2 Lithium bateries 1 x AA 1x 1/2 AA 3,6V

59
The JA-89P outdoor PIR detector
  • Based on an Optex product
  • 2 sensors (eliminate alarms caused by small
    animals)
  • IP-54 cover
  • Installation height 0.8 - 1.2 m
  • Adjustable detection angle
  • 1 x AA Lithium battery 3.6V

Covered area adjustable
area not covered
60
The JA-81M detector
  • Magnetic door / window detector
  • Status detector (optional pulse reaction)
  • DIP switches
  • DEL / INS (Natural reaction)
  • MG ON / OFF (enable/disable internal sensor)
  • 3 input terminals
  • TMP tamper input
  • IN1 NC / NO alarm input (1k balanced)
  • IN2 Roller-shutter input (3 activations within
    5s alarm, disconnection tamper)
  • 1x AA Lithium 3.6V battery

61
The JA-83M magnetic detector
  • Magnetic detector about 1/3 shorter than the
    JA-81M
  • Status detector (optional pulse reaction)
  • DIP switch
  • DEL / INS (Natural reaction)
  • 2 types of the magnets
  • Classic cube (see the picture)
  • Magnetic ring with a screw
  • 1x CR-123A 3V Lithium battery

62
The JA-82M window detector
  • Invisible window (door) detector (EURO or
    wooden)
  • To be installed in the frame of a window (door)
  • DIP switches
  • INS / DEL (Natural reaction)
  • TMP on / off
  • Status / Pulse reporting
  • 2 x CR2354 Lithium 3V battery

Back-plates
63
The CT-01 roller-shutter detector
  • Detects window shutter (curtain) movement
  • Principle ratchet-wheel generates the pulses
  • Can be used with the JA-81M

Example of the IN2 connection
64
The LD-81 flood detector
  • Can be connected to the JA-81M or JA-60N
  • Conductivity sensor
  • Protection of kitchen, bathroom, cellar
  • Should not be placed permanently
  • in water

65
The LD-12 flood detector
  • Hardwired detector
  • Protection of kitchen, bathroom, cellar
  • NO and NC output
  • Should not be placed permanently
  • in water

66
The JA-80S smoke detector
  • Fire detector (optical smoke temperature over
    60C)
  • Testing by test button or by aerosol
  • During alarm the siren can by stopped by pressing
    its button
  • Jumpers
  • FIRE / INS (Natural reaction, INS restaurant,
    fireplace...)
  • SIREN ON / OFF
  • 1 x AA Lithium 3,6V battery

Siren
Reaction
67
The JA-80G gas detector
  • Combustive gas detector (propane, methane..)
  • Sensor hot platinum wire
  • Mains powered
  • Can be tested with a cigarette lighter
  • DIP switches
  • 10 / 20 LEL (gas concentration)
  • MEM ON / OFF (memory function)
  • Output relay contact max. 6A

68
RC-8x controllers
  • To be enrolled by inserting a battery or pressing
    a button
  • Can be used with a control panel, UC and AC
    receivers and indoor siren
  • Communication range up to 100m

Controlling, panic..
Door bell, panic..
Personal panic
Controlling, panic.. (housing for 2 or 4 buttons)
69
The RC-86 key-fob
  • Universal two-band key-fob
  • 868MHz OASiS
  • 433MHz PROFI / Maestro / Comfort
  • Frequency setting is done easily just by the
    buttons
  • Communication range 30 meters
  • Housing for 2 and 4 buttons

Setting table
70
The RC-88 button
  • DIP switches
  • Panic (remote control or panic button function)
  • TMP (disable tamper sensors and communication
    supervision)
  • Can also be used with UC, AC and JA-80L
  • 1x 1/2 AA Lithium 3.6V battery
  • (3 year life time, max. 20 activations/day)

71
The RC-87 personal panic button
  • Can be enrolled to the control panel, siren or
    UC/AC modules
  • Optional
  • Wrist watch or necklace version
  • Audible confirmation of triggering
  • Delay (5s) to stop accidental triggering
  • No radio communication supervision
  • CR2032 lithium battery
  • Working range up to 200m

72
The RC-85 remote control module
  • Design to be installed in a car (12 to 24V)
  • 3 wires
  • GND
  • A if connected to U transmits arming signal
  • B if connected to U transmits disarming signal
  • both A B connected to U transmits a panic
    signal
  • Flashing full-beam headlights or blowing the horn
    send signals
  • Can also be used to transmit an alarm from a car
    alarm
  • Optional double click activation
  • No battery, powered by car

73
The JA-80L indoor siren
  • Mains powered
  • Disconnected from power during alarm tamper
    alarm
  • Disconnected from power without alarm low-bat
    warning (optional)
  • Enrolls by plugging in
  • Selectable alarm setting following PG
    outputs(alarm reporting from one section only)
  • Generates sounds
  • IW alarm
  • Exit and entrance beeps
  • Door bell - 8 melodies
  • Detector - triggered sounds - 8 melodies
  • LED indicates PGY status
  • Two volume levels (by keeping the button pressed)
  • Triple click enables/disables arming chirp sounds
  • Signal level measurement by pressing button

74
The JA-80A outdoor siren
  • Totally wire-free !!!
  • Loudness 112dB / 1m (increases gradually)
  • Max. duration of the siren sound 3 min.
  • Flashes 30 min. after the alarm
  • Jumpers
  • 50 / 25 s. (communication cycle with the control
    panel)
  • LED ON / OFF (warning flash every minute)
  • Enrolls by connecting its battery
  • Lithium battery BAT-80 (max. life time 3 to 5
    years)

75
Communicators
Position
  • External communication
  • GSM network GPRS, SMS, VOICE
  • Internet (LAN - Ethernet)
  • PSTN
  • Reports from the system
  • Remote access

76
Event reporting
Telephone network
INTERNET
and or
Automatic Receiving Center
User notification
Oasis
77
Remote access
www.GSMLink.cz
INTERNET
and or
Internet
Telephone
78
The JA-80Y GSM communicator
  • Communication via GSM/GPRS
  • Event reporting by
  • SMS (17 lang. selection)
  • Phone calls
  • ARC (IP, SMS or CID protocols)
  • Picture transmission (using JA-80Q module)
  • GSM gateway function
  • Remote access via
  • Phone (keypad registration or SMS)
  • Internet - www.gsmlink.cz
  • Unanswered ringing from an authorized phone
    number
  • ARC programming can be locked

79
The JA-80V LANPSTN communicator
  • Communication via LAN PSTN
  • Event reporting by
  • SMS (17 lang. selection)
  • phone calls
  • ARC (IP, CID or DR protocols)
  • Picture transmission (using JA-80Q module)
  • Remote access via
  • Phone (keypad registration or SMS)
  • Internet - www.gsmlink.cz
  • Unanswered ringing from an authorized phone
    number
  • ARC programming can be locked

80
GSMLink
  • Remote access by Internet

www.GSMLink.cz
81
1. Register at www.GSMLink.cz
  • User registration
  • Device registration

82
Configuration page example
83
The JA-80X voice communicator
  • Reports alarms with voice messages
  • Up to 4 phone numbers via PSTN
  • 7 voice messages
  • System name
  • Intrusion
  • Fire
  • Tampering
  • Panic
  • Technical alarm
  • Remote access welcome note
  • Allows remote access via telephone keypad
    authorization (DTMF)
  • Supports CID protocol transmission to ARC (PSTN
    line)
  • Can be combined with JA-80V or JA-80Y

84
The SP-02 speaker phone
  • Can be connected to PSTN or to the phone line
    simulated by JA-80Y
  • For listening in and talking
  • Answers calls from authorized numbers
  • Up to 8 phone numbers can be authorized
  • Push-to-talk feature to call an emergency number
  • Half-duplex communication allows a high
    sensitivity for listening
  • 2 x AA alkaline 1.5V battery

85
The JA-68 output module
  • For control panels of the 6x and 8x series
  • 8 galvanically-separated outputs
  • 9 terminals
  • C - Common
  • A - Set (Armed)
  • I - Intrusion
  • F - Fire
  • S - Tamper (Sabotage)
  • P - Panic
  • T - Fault
  • AC Mains dropout
  • LB Low Battery
  • Selectable NC or NO logic using a jumper
  • 12V and GND terminals power supply output,
    max. 100mA
  • Can be used in combination with a communicator
  • Designed as a general purpose device
  • Suitable e.g. for ARC radio communicators

86
The UC-82 relay module
  • Powered by 12V DC
  • 2 output relays (X Y) - max 2A
  • Low bat. output
  • External antenna is optional
  • Powered by 12V (20mA) external source
  • Can be used with
  • Control panel
  • Detectors
  • RC-8x transmitters

87
The AC-82 relay module
  • Powered directly from mains 230V, 50Hz
  • 2 output relays (X and Y) - max 5A
  • Can be used with
  • Control panel
  • Detectors
  • RC-8x transmitters
  • TP-8x thermostats

88
The TP-8x thermostats
  • TP-82
  • Regulated temperature adjust.
  • Temperature measurement
  • Lockable
  • Adjustable
  • Hysteresis
  • Operational limits
  • Sensor correction
  • Alarm thresholds
  • TP-83
  • Weekly program
  • Day/night temperature for every hour
  • Day temperature increase by 2C
  • Programme display
  • Adjustable
  • Hysteresis
  • Operational limits
  • Sensor correction
  • Alarm thresholds
  • Adaptive switch-on
  • AC-83
  • Receiver
  • Mains powered
  • 3 relays
  • Heating circuit 1
  • Heating circuit 2
  • Pump
  • Pump cleaning
  • Remote control of the heating
  • Common functions
  • AA 1.5V alkaline battery
  • Remote control via the control panel
  • Incl. antifreeze functions
  • Heating disabling when window is open
  • Freeze alarm
  • Fire alarm

89
The TP-8xIR thermostat
  • Wirelessly measures the floor temperature E by
    the IR sensor
  • Accurate comfortable regulation
  • TP-82IR, TP-83IR versions available
  • Two additional temperature settings
  • Minimal floor temperature
  • Maximal floor temperature

90
Smart heating system
Remote controls
Window detectors
Control panel
Thermostat
AC-82
Remote access and status information
Telephone
Heating
Operating the heating by windows CLOSED normal
heating OPEN anti freezing heating only
91
The JA-82T and JA-80BT interfaces
  • Connects control panel to PC
  • Provides USB or Bluetooth interface
  • Suitable for O-link, Comlink software

92
Something more
93
The GD-04 David GSM module
  • Tiny but handy

PC connection cable and GD-Link software
Backup module
DTMF module
Main unit
Power adapter
Radio module
Building-block-like modularity
94
GD-04 David features
  • Relay operation via a mobile phone
  • SMS instructions (of the type ON or OFF)
  • Instruction text can be edited
  • Maximum text length is 30 characters
  • SMS reports can be sent to inform about relay
    operation
  • Dialling-in from an authorized phone
  • Up to 50 tel. numbers can be programmed for each
    relay.
  • The switch-on period after dialling-in is
    configurable in the range of 1s to 10 hours
  • Each tel. number can have a limit to the number
    of calls (useful e.g. at parking-lots)

95
GD-04 David features
  • SMS reports on input activation
  • Each of the A to D inputs can have its
    activation/deactivation reported
  • Up to 8 tel. numbers can be programmed for each
    input.
  • Maximum report text length is 30 characters.
  • SMS reports can be emphasized by subsequent phone
    calls.
  • Device input state can be interrogated
  • By the SMS instruction STATUS (editable)

96
GD-04 David programming
  • Via a mobile phone using SMS instructions
  • Only 8 instructions (texts, numbers, other
    functions)
  • An instruction starts with an access code ( PC
    by factory default)
  • Multiple instructions in a single SMS (usually,
    only one SMS is needed to program the whole
    configuration)
  • Using a PC running GD-Link software
  • A CD and a USB connection cable
  • supplied with the package
  • Via the Jablotron web page
  • Fill-in a form
  • Send it
  • You get an SMS reply (PROGRAM OK)
  • Free of charge, no registration needed

Simple and elegant.....
97
News on the car alarm product range
98
CA-1803 BT ATHOS
  • Car protection
  • Reporting of alarms by SMS or phone calls
  • Remote immobilization via SMS instructions
  • Garage protection using wireless JA-8x detectors
  • Listening-in to the car using an HF-03
  • hands free set optional
  • Remote control key-fob, phone or the Internet
  • Logistics support
  • Car navigation via a Bluetooth connection to a
    PDA or to a mobile phone
  • Monitoring car use (location) via the Internet
    (suitable for monitoring work journeys)
  • Additional features
  • Operating car appliances
  • Hands-free calling from the car using an HF-03
  • ARC supervision

99
GSMLink car location monitoring
Write a Comment
User Comments (0)
About PowerShow.com