Title: UPS SG-CE Series 160-300 kVA


1
UPS SG-CE Series 160-300 kVA
Sales presentation
2
PRODUCT HIGHLIGHT
3
Product portfolioCE Marked, 3x380/400/415V In
Out, 50/60Hz
UPS SG-CE Series 160kVA 144 kW UPS SG-CE Series
200kVA 180kW UPS SG-CE Series 160kVA
PurePulseTM 144kW UPS SG-CE Series 200kVA
PurePulseTM 180kW UPS SG-CE Series
250kVA 225kW UPS SG-CE Series 300kVA 270kW UPS
SG-CE Series 250kVA PurePulseTM 225kW UPS SG-CE
Series 300kVA PurePulseTM 270kW
Thyristor rectifier
IGBT rectifier
160 200 kVA
Thyristor rectifier
IGBT rectifier
250 300 kVA
4
Double conversion parallelableDesigned for
Mission Critical Applications
5
High power concentrationNew technology for
actual and future trend
6
Performances for actual and future trendHigh
efficiency and clean input technologies for
modern applications
7
Superior output dynamic stiffness Technology for
actual and future trend
8
TYPICAL APPLICATIONS
9
Typical applicationsDesigned for mission
critical applications, with highest levels of
protection and reliability
Data centers Medical equipment healthcare
facilities Transportation Infrastructure Call
centres Security system and more ...
10
IEC 62040-3 CLASSIFICATION
11
Performance IEC 62040-3 Level 1Output voltage
dependancy
Level 1 Output voltage dependency from utility
(XXX YY ZZZ)
12
Performance IEC 62040-3 Level 2Output voltage
quality
Level 2 Output voltage quality depending on load
(XXX YY ZZZ)
Sine wave THD lt 8 (IEC 61000-2-2/-4) for all
linear and non-linear loads Non-sine wave THD
gt 8 with non-linear load Non-sine wave
out of tolerance of IEC 61000-2-2/ -4
S
S
X
X
Y
Y
Battery operation Normal operation
13
Performance IEC 62040-3 Level 3Dynamic output
voltage
Level 3 Dynamic output voltage behaviour (XXX YY
ZZZ)
Class 2
Class 3
Dynamic load changes with non-linear load (0
100 0) Dynamic load changes with linear load
(0 100 0) Change of operation mode
(Utility battery / Inverter - By-pass)
14
SG CE classificationExeeding IEC 62040-3
standard requirements
SG CE classification VFI SSS
111 VFI Voltage Frequency Independent Frequenc
y Converter operation available SS Output
voltage THD lt 8 for all loads THDv lt
1.5 linear loads THDv lt 3 non-linear
loads 111 Class 1 performance Exceeding Class
1 Best in Class dynamic response /- 3 at
load step 0-100-0 /- 2 at load step 0-50-0
15
CHARACTERISTICS PERFORMANCES
16
UPS configurationDouble conversion with inverter
output isolation transformer
  • Double conversion (VFI) technology with output
    isolation transformer
  • Automatic bypass for overloads, short circuit and
    UPS disturbances conditions
  • Manual bypass for UPS maintenance operations
    without load interruption
  • Protection safety devices integrated (back feed
    protection k6 standard)

17
Compact designTrue front access for operation
and maintenance, saving installation space
  • Reduced footprint
  • Compact design saving space in installation
  • - 160-200 kVA 1350 x 850 x 1900 mm- 250-300
    kVA 1500 x 850 x 1900 mm
  • Easier to handle in narrow space
  • True front access
  • Installation against a wall
  • More space available for other equipments
  • Reduced weigh
  • Easier to handle into installation site(e.g.
    transportation though floors by lift)
  • Reduced installation time and cost

UPS
850
1.600
1.350
Footprint SG 200kVA UPS 1.350 x 0.850 1.15
sqm Operational 1.350 x 1.600 2.16 sqm
18
Highest UPS output power capabilityCapability to
supply Inductive, Resistive and Capacitive loads
  • Full range power capability
  • Designed to supply real power for any type of
    application
  • - inductive loads- resistive loads- capacitive
    loads
  • No over-sizing required to supply resistive and
    capacitive loads
  • Suitable for modern power supply application with
    unit or capacitive power factor (e.g. new servers
    generation), crest factor up to 31

E.g. SG 300kVA load capabilities Inductive load
PF0.9 270 kW / 300 kVA Resistive load PF1 270
kW / 270 kVA Capacitive load PF0.9 270 kW / 300
kVA
19
Input rectifier performances Wide input window
to preserve battery autonomy and lifetime
Input window
  • Wide input voltage and frequency windows
  • Limited use of battery
  • Preserve battery autonomy for real input mains
    failures
  • Increase battery lifetime
  • Soft start
  • Rectifier can be activated gradually,
    controlling the input current
  • Preventing instable situation for GenSet
  • Avoids false trip of upfront protection devices
  • Sequential softstart for parallel UPS

Input frequency
Input voltage
Soft start
UPS input current
UPS 1 UPS 2
100 0
time
20
Backfeed protection IEC 62040-1 For fixed
installation UPS, backfeed protection may be
provided internally or externally to the UPS in
the a.c. input line
  • Standard feature inside UPS cabinet
  • No additional cost required
  • No addition installation required
  • Fully compliant with IEC 62040-1
  • Compliance to UPS installation safety
    requirements
  • Safer operating condition
  • Safer operation for end users and service
    engineers

preventing feedback to the mains from the
inverter in case of mains failure and a fault in
the bypass circuit
21
IGBT technology for clean input Pure Pulse
configuration for highest input performances
PurePulse technology for IGBT rectifier
  • UPS input performances
  • Total Current Harmonic Distortion THDi2
  • UPS input power factor 0.99
  • Constant behavior at all loads
  • Negligible harmonics contents at full and
    partial loads
  • Benefit on input mains
  • Saving in the sizing of upfront equipments e.g.
    GenSet, cablings, circuit breakers,
  • No disturbances to nearby equipment
  • Saving cost due to additional filters

22
Perfect integration with GenSetNo GenSet
oversizing required
GenSet integration
  • Compatible with GenSet design
  • Saving GenSet size(suggested GenSet vs. UPS
    ratio 1.1)
  • Reducing GenSet installation space
  • Saving GenSet investment
  • GenSet system integration
  • GenSet integration via Customer Interface
    (dedicated auxiliary contact)
  • Programmable functions based on GenSet working
    condition (Gen on/off)
  • Pure Pulse configuration and GenSet able to
    manage large load steps

Example
Load 300 kVA PF0.8 240 kW UPS SG 300 kVA
Pure Pulse input PF 0.99 GenSet
data reactance subtr. Xd12 GenSet size min.
size required 332 kVA GenSet/UPS 332/300 1.1
23
Superior Battery Management Safe and protected
battery management to preserve investment and UPS
reliability
  • Flexible applications
  • Different battery technologies applicable PB
    sealed (VRLA) - PB vented NiCd
  • Wide autonomy range (from few minutes to some
    hours)
  • User friendly information
  • Prediction of true back-up time, based on load
    status
  • Alarm for stop operation to prevent any
    unknown shut-down
  • Monitoring and control
  • Battery test (programmable or manual) preserve
    UPS system reliability
  • Battery earth fault detection safer operation
    for service engineer end user


Voltage temperature compensation
24
No output voltage distortion Best in class
inoutput dynamic stiffness
  • No output voltage distortion with linear and
    non-linear loads
  • Voltage distortion - linear loads THDv lt 1.5
  • - non-linear loads THDv lt 3
  • Enhanced customer productivity
  • Improved quality of application, reducing stress
    for loads supplied
  • Increased uptime and MTBF of customer
  • Reduced service intervention (e.g. medical
    applications 60 labor hour spare parts
    reduction)

output voltage

current
output voltage
current
25
Output Dynamic Stiffness Best in class inoutput
dynamic stiffness
Medical scanner - dynamic current absorbtion
  • Best in class in output voltage variation with
    load steps
  • Static lt 1
  • Dynamic at load steps 0-50-0 lt 2
  • Dynamic at load steps 0-100-0 lt 3
  • Enhanced customer unit productivity
  • Improved quality of application (i.e. medical
    images)
  • Capability to supply critical loads with high
    and fast loads steps (pulsating loads)
  • Increased uptime and MTBF of customer
  • Reduced service intervention

1 ms
26
EFFICIENCY
27
High Efficiency at all loads Reduced customer
operation costs and cost saving in air
conditioning design
  • High efficiency performances at any load
  • High efficiency at full and partial loads for
    real benefit in operating conditions
  • Energy cost saving
  • Reduced cost of customer equipment operation at
    all loads
  • Air conditioning cost saving
  • Reducing size and cost of air condition system
  • Reducing consumption and related operating cost

SG CE PurePulse (IGBT rectifier) 1 less
28
Super Eco Mode - functionalityImproving UPS
efficiency
Normal mode
  • Normal mode
  • The output voltage is newly generated,
    independently from the input voltage
  • Heat losses are present in rectifier and inverter
  • Super Eco Mode
  • Load is supplied via the bypass
  • UPS rectifier keeps the battery charged
  • UPS inverter switched off(no heat losses)

Super Eco Mode
29
Super Eco Mode - benefitHigh efficiency,
preserving protection to critical load
lt 2ms
  • High efficiency 98
  • prevents heat losses
  • saving customer utility bill
  • Fast transfer time to inverter lt2 ms
  • Guaranteed safe energy for the application
  • Configurable according to load requirement
  • Adjustable bypass supply tolerance
  • - voltage /- 10 (adjustable)
  • - frequency /- 5 (adjustable)

Bypass on/off
Output voltage
Inverter current
Inverter control
30
RPA
31
Reduntant Parallel Architecture True redundancy
with no single point of failure
  • Modular design
  • Future system expansion
  • Saving investment
  • True redundancy
  • No single point of failure
  • Decentralized bypass
  • Distributed parallel management system
  • Increased system reliability
  • Safe and reliable power supply for mission
    critical applications
  • Increase productivity
  • True redundancy with no single point of failure

32
Reduntant Parallel ArchitectureIncrease system
reliability for Mission Critical Applications
  • Configurable up to 6 units in parallel
  • Future expansion
  • Safe and reliable power supply
  • Redundant Communication Bus
  • Easy to install and maintain
  • Easy system upgrade/downgrade
  • Maintenance operation withoutload interruption

utility supply
critical load
33
EMC
34
EMC - Electro Magnetic Compatibility immunity
IEC 62040-2 standard defines the limits of
maximum allowable levels of emission of
electromagnetic disturbances for UPS systems
  • Emission
  • Any electronic devices emits electromagnetic
    disturbances - radio frequency waves - through
  • cables (conducted emissions)
  • air (radiated emissions)
  • Immunity
  • All electronic equipment is sensitive for
    electromagnetic waves.These waves can disturb
    the functions of these equipments
  • Electro Magnetic Compatibility
  • Disturbances tolerance among different types of
    equipment when running in the same environment.

35
EMC Category C2 (Class A), optional feature
Compensation of radio-frequency emission to
avoid distrurmabces on nearby equipments
  • No interference with other equipments
  • Avoid any interferences with critical
    applications sensitive to radio frequency
    emission (e.g. telecom, broadcasting, )
  • No additional investment required for EMC
    investigation.
  • Protected unit quality enhancement
  • Increased quality and productivity (e.g. Image
    quality in medical application)

Additional EMC cabinet required
36
SERVICEABILITY
37
Designed for serviceabilitySaving time and cost
in service
  • Easy maintenance interventention
  • Reducing time and cost on maintenance
    intervention
  • Reducing down-time, increasing availability

38
Fan failure detectionVentilation monitoring for
highest reliability
fan failure
  • Ventilation monitoring
  • Alert before overheating occurs
  • Continuos monitoring of cooling system
  • Repairing time reduction
  • Fault level decreasing

detection
alarm
39
POWER QUALITY SYSTEMS
40
Power Quality Systems Integretion with other
Power Quality euipments for Mission Critical
Applications
41
INTEGRATION WITH BMS
42
Customer interfaceEasy integration with
Building Management System (BMS)
Customer interface
  • UPS supervision capability
  • 1x RS232 Serial Communication Port
  • 6 programmable potential free alarm contacts -
    D plug - Terminals blocks
  • 1x Emergency Power OFF contact
  • 1x Gen-ON Input contact
  • 1x Control Input contact
  • Additional interface
  • SNMP Interface Card(10/100Mbps auto-select)
  • MODBUS RTU Interface (RS232 or RS485)

43
CONNECTIVITY
44
IRIS - Intelligent Remote Information System
Remote monitoring and diagnostics solution
  • SNMP/Modem/GPRS topologies available
  • Flexible, safe and customer-friendly solution for
    remote monitoring
  • Secure communication via
  • e-mail, SMS, fax
  • GPRS
  • Web/PDA

Data Acquisition
Communication Medium
User Interface