Title: Parker ZANDER Adsorption Dryer
1Parker ZANDER Adsorption Dryer
- K-MT 1-95 heatless adsorption dryer series
2What changes came with the re-design 2011?
- ... to the small dryer series ?
- K-MT 1-8,
- KA-MT 1-8,
- AKM 1-8,
- BSP-MT 1-8
3Changes in the ecodry-seriesK-MT 1-8 und KA-MT
1-8
- Validated GL-Filter range
- After-filter ZL-Grade (1 µm)
4Changes to the AKM 1-8 series
- Validated After-filter fromthe GL-series now
pre-mounted - ZL-Grade (1 µm)
5Changes to the BS-MT 1-8 BSP-MT 1-8 series
- BS-MT 1-8 replaced
- BSP-MT 1-8 for industrial andmedical breathing
air - Nominal capacities at 13 bar(g)
- Validated GL-Filter series
- ZL- Grade After-filter (1 µm)
6Changes An overview
Characteristics Generation 1 to Generation 2
Volumetric Flow Nominal change in BSP-MT series
Pre-Filter G_XP(D) to GL_XL(D)
After-Filter G_V(D)H to GL_ZL(D)H
Connections Size 6 and 7 with G1/2, Size 8 with G3/4
Series K-MT 1-8 Apart from that unchanged
Series KA-MT 1-8 Apart from that unchanged
Series AKM 1-8 With After-filter GL_ZL(D)H
Series BS-MT 1-8 Replaced
Series BSP-MT 1-8 For both industrial and medical breathing air
7What changes came with the re-design 2011?
- ... to the welded pressure-vessel series?
- K-MT 10-95,
- KA-MT 10-95,
- AKM 10-95,
- BSP-MT 10-95
8Changes to KE-MT 10-95
- Modular, bolted-construction
- ValidatedGL-Series filters
- ZL-Grade After-filter (1 µm)
9Changes to KEA-MT 10-95
- Modular, bolted-construction
- ValidatedGL-Series filters
- ZL-Grade After-filter (1 µm)
10Changes to AKM 10-95
- Validated GL-Series After-filter pre-mounted
- ZL-Grade (1 µm)
11Changes to BS-MT 10-95 BSP-MT 10-95
- BS-MT 10-95 replaced
- BSP-MT 10-95 for industrial and
medicalbreathing air - Nominal capacity at 13 bar(g)
- Modular, bolted construction
- Validated GL-Series Filters
- ZL-Grade After-filter (1 µm)
12Standards for breathing air
13Changes An Overview
Characteristics Generation 1 to Generation 2
Volumetric Flow Nominal change to BSP-MT series
Pre-Filter G_XPD to GL_XLD
After-Filter G_VDH to GL_ZLDH
Connections Size 25 with G1 1/2, 60 with G2 and 95 with G2 1/2
Series K-MT 10-95 Modular, bolted twin-vessels
Series KA-MT 10-95 Modular, bolted vessels (3 in a row)
Series AKM 10-95 Modular, single-vessel with pre-mounted after-filter GL_ZLDH
Series BS-MT 10-95 replaced
Series BSP-MT 10-95 Modular, bolted vessels (3 in a row)System for industrial and medical breathing air
14Digression Function principles
- Prefiltration
- 99,9999 efficiency of removal of particles
and liquids down to 0,01 µm - Oil down to 0,01mg/m³
- float drain as standard
15Digression Function principles
- Adsorption
- Air flows through the vessel from bottom to
top.The desiccant adsorbsthe moisture from the
compressed air down to a -25/-40U/-70 C
pressure dew point.
16Digression Function principles
The blow-off valve opens and via a calibrated
orifice the expanding air carries the moisture to
the atmosphere.
17Digression Function principles
- Re-PressurisationThe blow-off valve closes and
via the orifice a build-up of pressure takes
place. - Stand-byUntil the switch between the vessels
Once again adsorption phase and repeating cycle.
18Digression Function principles
- After-filter at outlet
- 99.925 efficiency of particle removal down to
1 µm - Hold back of dessiccant abrasion
- Manual drain
19Digression Function principles
- Total cycle time10 min
- Adsorption time5 min
- Desorption time4 min
- Re-pressurisation time1 min
20Proven advantages remain unchanged
- 16 sizes PN16 for volume flows of
- 8 to 940 m³/h compressed to 7 bar(g) for
K-MT/KA-MT/AKM and - 13 to 1371 m³/h compressed to 13 bar(g) for
BSP-MT 1-95 - including installed pre- and after-filters
- high grade molecular sieve/activated carbon
- compact design /small foot print
- tension-free, leckage minimised valve block or
plates
21Proven advantages remain unchanged
- Separately controlled main valves Ensure clear
flow paths! - 10 minutes cycle time Lowers the regeneration
air need to a minimum! - Multitronic-Plus-Control
- ... with dew point control for pdp -25 to -70
Cself-adopting to current system utilization
no waste of regeneration air! - PED/AD2000 with 1 million load alternations19
years continuous duty by a 10-minutes-cycle
22Control Multitronic Plus
- Zander standard for all heatless regenerated
dryers - Compressor synchronization contact
- Dew point sensor ZHM100 retrofittable
- Variable cycle up to 60 min.
- Dew point setting from -25 up to -70 C
- Power supply230 V/50-60 Hz, 115 V/60 Hz, 24 V DC
23These advantages are new
- Air quality classes acc. to ISO 8573-12010K-MT
2 1-2 2KA-MT 2 1-2 1AKM 2 - 1 - Delivery times for all series with or without dew
point control only 7 working days after order
income of the PSC
24Our new sales concept
- Defined portefolio of standard products with few
alternatives (ex works) - Extra accessories available
- Full range of Service Kits and Despacs, Desmixes
available
25Value Proposition
26Benefit no. 1
- inlet valve-combination withsingle-acting valves
- outlet valve-combination with non return valves
- low number of threaded connections
- low number of seals
27Benefit no. 2
- separately operated main-valves
- clear flow-paths through the dryer at any time
- process reliability
28The competition
The position of switching valves, used by many
competitors, is functionally unsafe!
29Benefit no. 3
- Extremely robust
- Even flow distribution via perforated support
base ensures full use of the desiccant surface
area. - Lowers the pressure drop.
-
- No moisture spots.
- Gasket replacement without the discharge of
dessiccant.
30The competition
Almost all other competitors use simple dust
sieves
A socket below the weld seam of the vessel shell
No maintenance at the lower connections without
discharging the dessiccant.
Moisture spots, a limited flow stream, a higher
pressure drop are the calculated impacts.
31Benefit no. 4
- Total cycle time 10 minutes
- Adsorption time 5 min
- Regeneration time 4 min
- Re-pressurization time 1 min
- Reduced regeneration air need of 14.4 !
32The competition
- 8 min cycle time requires 15.7
- 6 min cycle timerequires 18.1
- 4 min cycle timerequires 24.7
33Benefit no. 5
- Actually controlled by pressure dew point
- Multitronic control in combination with dew point
sensor ZHM100 - Dew point control for variable load situations
- Change-over between the vessels just before the
tolerable residual humidity is reached - Extension of the adsorption phase lowers the
frequence of regeneration air need over time
34The competition
almost all competitors use simple temperatur
transmitters
arising adsorption heat as indicator for the need
of vessel change-over
So-called Economy systems for pleasure yet not
for a process reliable control
not feasible for multi-bank systems
not feasible for switching valve design at dryer
inlet
35Parker ZANDER Adsorption Dryer
- K-MT 1-95 heatless adsorption dryer series
THANKS FOR YOUR ATTENTION