Title: Does phacoemulsification alter pupil size and position


1
Does phacoemulsification alter pupil size and
position
  • Sanghamitra Burman MD FRCS
  • Julian D. Stevens MD FRCOphth
  • Moorfields Eye Hospital, London, UK
  •  
  •  

2
Aim
  • Purpose To determine the changes in pupil size
    and position following uncomplicated clear
    corneal phacoemulsification
  • Setting Anterior Segment and Refractive Surgery
    Service, Moorfields Eye hospital, London, UK
  • Study Design A prospective, non-comparative,
    interventional case series

Hartman-Shack Aberrometer
3
Methods
  • 23 healthy subjects including 9 men and 14 women
    scheduled to have cataract surgery or refractive
    lens surgery were recruited in this study.
  • Clear corneal phacoemulsification was performed
    for cataract in 20 patients and for refractive
    lens exchange in 3 patients.
  • The scotopic pupil size in 34 eyes was measured
    with a Hartman-Shack wavefront aberrometer (Visx
    WaveScan).
  • Measurements were performed preoperatively and
    between 4-10 weeks postoperatively.
  • A single surgeon operated upon all the eyes and a
    single observer performed all measurements.

4
Results
Distribution of change in pupil size and centre
5
Results
  • Paired Students t-test was used to evaluate the
    differences.
  • p value 0.159
  • There was no statistically significant
    difference between preoperative
  • and postoperative mean scotopic pupil sizes.
  • The shift in pupil center does not show a trend.
  • For most eyes the postoperative pupil was
    smaller.

6
Discussion
  • The integration of wavefront technology and lens
    based surgery represents a step toward improving
    functional vision and quality of life for
    cataract patients. The Tecnis Z9000 IOL (Pfizer,
    New York) has been designed with a modified
    prolate anterior surface to compensate for the
    spherical aberrations of the cornea, thus
    eliminating total spherical aberration.1Results
    show that the Tecnis IOL may produce better
    contrast sensitivity than a standard spherical
    IOL under mesopic and photopic conditions.2 If
    this modified prolate IOL was centered within 0.5
    mm and tilted less than 7 degrees, it would
    exceed the optical performance of a conventional
    spherical IOL. 3
  • Pupillary alterations may have implications on
    the implantation of prolate intraocular lenses
    (IOL) and refractive surgery for post cataract
    surgery residual refractive errors. A shift in
    pupil position may negate the benefits of
    aspheric IOL implantation.

7
Conclusions
  • In the present study uncomplicated clear corneal
  • phacoemulsification did not significantly modify
  • scotopic pupil size or position.
  • References
  • Packer M, Fine IH, Hoffman RS. Wavefront
    technology in cataract surgery. Curr Opin
    Ophthalmol. 200415(1)56-60.
  • Packer M, Fine IH, Hoffman RS, Piers PA. Improved
    functional vision with a modified prolate
    intraocular lens. J Cataract Refract Surg.
    200430(11)2247-8.
  • Holladay JT, Piers PA, Koranyi G, van der Mooren
    M, Norrby NE. A new intraocular lens design to
    reduce spherical aberration of pseudophakic eyes.
    J Refract Surg. 2002 18(6) 683-91.
  •  
  •  