Title: Secure Care Products, Inc' Concord, NH An ISO9001 Certified Company
1 Secure Care Products, Inc. Concord, NH An
ISO9001 Certified Company
- Introduces the New
- Model 135 Non-ID SeriesLong Term Care Systems
for Wandering Monitoring and Access Control
Applications
2New Look Access Control Transmitter Based
Selective Monitoring Panels
135DE
135
135DE
135
500DE
3What has changed compared to the Legacy ADV
500DE, ADV 1000 ADV 1000DE Panels?
- Frequency change from 430KHz to 13.56MHz
- Flexibility of wrist or ankle placement of
resident transmitter - Antenna/receiver built into the exit panel
- Faceplate and mounting boxes are all plastic
- Louder alarm sounder from exit panel
- Non-volatile memory means no loss of programming
or codes - One software version covers all code requirements.
4Additional Feature Set Improvements
- Single or double door can be covered with one
single wandering monitoring kit - Programmable escort times from 0 secs. to 15
minutes - Addition of a third reset or escort code
- Advanced Security Mode is now a default feature
set - More flexibility with N/O or N/C dry contacts for
interfacing with other devices.
5New 500DE...Where would this be used
- For use on those doors that will generally be
locked all of the time.(stairwell, smoking area) - Access and Exit is accomplished by entering a
code through keypad on panel side, and through
remote keypad, pushbutton, or palm switch on
other side. - System normally locked or if no locks will alarm
if anyone enters or exits without first entering
the code.
6New 135.Where would this be used?
- Monitoring the elevator opening or now can be on
the car - Sliding doors
- High staff traffic doors such as kitchen or
laundry - Monitoring a hallway space instead of a door
- Monitoring a second door in a path of egress
already locked by a 135DE or Resident ID door
7New 135DE.Where would this be used?
- Any locking door with high visitor traffic where
a wanderer/exit seeker could try to tailgate - Primary exit doors having our mag lock where
non-wandering residents are allowed to freely
move about the facility - Typically any main entrance, and can be either
single or double door that can have our mag locks
135DE
8Installation Product Related Improvements
- Brighter and added number of universal symbol
LEDs - All adjustments made through keypad
- Power up/down doesnt affect programming due to
non-volatile memory - Significant free memory space to accommodate
future product feature sets - Listed to UL 1069 Hospital Signaling and Nurse
Call equipment standard when listed components
and cabling used
9What These Changes Mean For Our Resellers?
- Ability to offer ankle/wrist placement systems
for your customers - More protection for your customers from RF noise
related issues - Listing to UL 1069 standard will open up
opportunities previously not accessible - Better value for your customers with additional
feature sets and product programming flexibility
10Secure Care Products, Inc. Concord, NH An
ISO9001 Certified Company
Manufacturers of Healthcare Selective
Monitoring Systems Since 1979
11Building a System With the New 135 Series
Equipment
Secure Care Products, Inc.
12Building a New 500DE, 135, 135DE System
Equipment List
Door Description 1 ..customer wants
- (1) 937 single door 500DE kit
- (2) A41010901 individual power supplies
- (1) A05030900 remote keypad
- (1) A05031031 2' ribbon cable
- (1) 402 mounting box for keypad
- C60006414 lock wire
- Single Door
- Access control
- flush mount
- lock
- remote keypad outside
13Building a New 500DE, 135, 135DE System
continued..
- Door Description 2
- ..customer wants
- Double door
- Access control
- surface mount
- locks
- PB inside
- Equipment List
- (1) 934 double door 500DE kit
- (2) A41010901 individual power supplies
- (1) A04150900 push button(N/O) request to enter
- (1) 402 mounting box for keypad
- C60006414 lock wire
14Building a New 500DE, 135, 135DE System
continued..
- Door Description 3
- ..customer wants
- Single door
- Wandering
- flush mount
- remote keypad inside
- Equipment List
- (1) 850 135DE flush mount kit
- (1) 1922 door contact
- (1) A41010901 individual power supplies
- (1) A05030900 remote keypad
- (1) A05031031 2' ribbon cable
- (1) 402 mounting box for keypad
-
15Building a New 500DE, 135, 135DE System
continued..
- Door Description 4
- ..customer wants
- Double door
- Wandering
- flush mount
- locks
- remote keypad inside
- Equipment List
- (1) 862 135DE flush mount kit
- (1) 983 external secondary receiver -optional
- (2) A41010901 individual power supplies
- (1) A05030900 remote keypad
- (1) A05031031 2' ribbon cable
- (1) 402 mounting box for keypad
- C60006414 lock wire
16Building a New 500DE, 135, 135DE System
continued..
- Door Description 5
- ..customer wants
- Glass front Entrance
- Double door
- locks
- flush mount
- Card access
- Equipment List
- (1) 862 135DE flush mount kit
- (2) A41010901 individual power supplies
- (1) 983 external secondary receiver
- C60006414 lock wire
17Building a New 500DE, 135, 135DE System
continued..
- Reporting Stations
- ..customer wants
- Door reporting requirements
- ( 2 Nurse Station locations)
- Equipment List
- (2) A02040901 8CH nurse consoles
- (2) A41010901 individual power supplies
- (2) 449 flush mount boxes
18Building a New 500DE, 135, 135DE System
continued..
- Other Equipment
- Wire P/Ns
- TXs
- straps
- Testers information
- Equipment List
- (0) C60005220 Fire Alarm wire
- (0) C60006412- Communication Wire
- (0) C60006413- External receiver wire
- (0) C60008473- Power Wire from Central Power
Supply - (0) A21350900 3 year non-ID 135 TX
- (0) C25000516 1 dozen adult imprinted TX straps
- (0) A07290935 non-ID 135 tester
19 Secure Care Products, Inc. Concord, NH An
ISO9001 Certified Company
-
- NEW Model 135 Non-ID SeriesLong Term Care
Systems for Wandering Monitoring and Access
Control Applications