Title: Electrogastrography (EGG)
1Electrogastrography (EGG)
The POLYGRAM NET ElectroGastroGraphy Application
is intended to record, store, view and analyze
gastric myoelectrical activity as an aid in the
diagnosis of gastrointestinal motility disorders.
2Electrogastrography (EGG)
EGG is a non-invasive technique that permits
prolonged and repeated recordings of gastric
electrical activity
EGG detects abnormal myoelectrical rhythms,
providing an easy way to define motor
pathophysiology it helps doctors to stratify
patients and improve confidence in their
therapheutic recommendations
3Objective of EGG tests
- To access whether and to what degree electrical
dysrhytmia of the stomach exist in those patients
with symptoms suggestive of a gastric motor
abnormality. - These symptoms include early satiety after a
meal, bloating, epigastric pain, nausea and
vomiting
4Diseases (conditions)
- Gastroparesis
- Functional Dyspepsisa
- Nausea vomitting
5Major Regions of the Stomach
- The Fundus, provides a reservoir for food
allowing it to be accomodated without an
excessive increase in intragastric pressure - The Corpus, where the enzyme pepsin is
produced. The gastric pacemaker is located at
the great curvature of the corpus. - The Antrum, where the hormone Gastrin is
produced and where mixing and grinding of the
food takes place - The Pylorus, is the valve between the stomach
and the duodenum. It helps controling the
emptying of the stomach contents into the
duodenum
Duodenum
6Electrogastrography
- The normal EGG activity is around 3 cpm
- The gastric pacesetter generates an electrical
signal every 20 sec, that travels towards the
antrum, and in response to a caloric challenge or
drug, creates powerful peristaltic contractions
that force antral contents towards the pylorus
and assist in grinding and mixing food.
Duodenum
7Myoelectrical activity
In normal humans we see an increase in overall
amplitude after a meal
8Diseases (conditions)
- Gastroparesis (A slight degree of
gastroparalysis) - Functional Dyspepsia ( A range of symptoms
associated with food intake) - Nausea vomiting
9Clinical applications
- Non-ulcer functional dyspepsia detected by
gastric dysrhythmia - Gastroparesis detected by a drop in EGG
peak power and/or post-prandial decreased
activity in 3 cpm range - Monitor efficacy of prokinectic agents
- Assess the risk of post-operative retching and
complications in laparotomy Nissen Fundoplication
10EGG multi-channel analysis
- Why perform a multi-channel analysis ?
- Detect whether the pacemakers frequency remains
constant (coupled) or becomes uncoupled as it
propagates down the stomach. - Detect whether the power of the signal increases
as it migrates to the antrum - suggesting normal
contractility in the stomach after a meal or a
prokenetic agent
11Improved diagnostic confidence
- EGG can select those patients who will
respond to prokinetics - In combination with gastric emptying scintigraphy
test - which gives motor activity results- we can
confirm or exclude a gastric motor abnormality
and identify or exclude a myoelectrical etiology
12Spectrum analysis graph ( EGG)
- Healthy patient
- Increased signal power/amplitude postprandially
- Gastroparesis
- No increased signal in response to a solid meal.
- The dominant frequency postprandially is
abnormal tachy- and/or bradygastria / dysrythmia
13Equipment Accessories
- Polygraf ID minimum 8 channels
- EGG main cable
- 1, 3 or 4 ch. extension cable
- Ag/AgCl electrodes
- Skin preparation gel paste
- Motion sensor cable
14Polygraf ID - POLYGRAM NET
15Capture Mode
On line RSA 1 time period
4 EGG channel Real time display
Period markers
Preprandial
Meal
Postprandial
RSA Running Spectrum Analysis
Motion Sensor Channel
16Verify
Preprandial
Meal
Postprandial
Fundus
Corpus
Channel Graph selection display
Tools cut, graph, Go to.
Add Event
Antrum
Pylorus
17Clinical View
Normal Patient
18Brady-Arrhythmia
19Matrix View
Normal Patient
20Unique features (i)
- Integrated impedance check
- Tests impedance in less than 5 sec.
- Step by step on screen guide (skin preparation
and electrode placement) - Multi-channel analysis
- Ease of use
- No calibration
- Clinical protocol and report
- POLYGRAM NET software platform
- State of the art analysis algorithms by
Dr. Chen facilitates short term and long
term analyses of recorded data
21Unique features (ii)
- Symptom diary
- Windows 2000 operating system
- Real-time on-screen Running Spectrum Analysis
during capture facilitates easy artifact
detection and removal
22Customers
- Mainstream gastroenterologists
- Adult gastric emptying specialist
- Pediatric gastroenterologist
- Antireflux surgeons
- GI Physiologists
23Enterra therapy
- Implantable pacemaker for the stomach
- A treatment of chronic nausea and vomiting
associated with gastroparesis when conventional
drug therapies are not effective
24Enterra Therapy results..
25Competitors
- 3CPM
- Currently most prominent competitor -
distribution via Sandhill - Old system, chunky technology, DOS based, EGG
only - MMS
- Up to seven channels
- FFT analysis, DOS based
-
26FUNCTIONAL DIAGNOSTICS