Title: NOTIFIER
1NOTIFIER
- IP Communicators
- The Modern Age of Central Station Reporting
2Agenda
Agenda
- An Overview of IP for Monitoring
- IP Solutions
- Code Compliance
- Compatible Fire Alarm Systems
- Summary
3An Overview of IP for Monitoring
- IP Fire Alarm Monitoring
- Secure, reliable fire alarm communications method
using IP network - Viable choice for those experiencing POTS
communications troubles - Telco providers are multiplexing to save cost
- Analog lines going away!
- Reduces or eliminates monthly cost of analog
phone lines to the end user - Compatible to VoIP routers and VoIP provider
networks - Connection Supervision increased from once every
24 hours to once every 90 seconds
4An Overview of IP for Monitoring
- Why IP? Why now?
- Current TCP/IP networks are mature, robust and
reliable - Mission-critical services (bank and stock
transactions, retail, etc) rely on IP, why not
Fire Alarm? - Traditional telephone systems removed in favor of
VoIP - Increases efficiency of alarm transmission
- Always on - No need for call setup
- High transmission speeds - Alarm is transmitted
in seconds - Internet access is shared - No need to pay for
an extra IP line - At the customer location
- Many lines at the Alarm Receiving Center (ARC)
5An Overview of IP for Monitoring
- Faster alarm transmission
- Means help arrives faster
- Full Contact ID reporting to pinpoint trouble
fast - Always on - No need for call setup
- High transmission speeds - Alarm is transmitted
in seconds - Internet access is shared - No need to pay for
an extra IP line - At the customer location
- Many lines at the Alarm Receiving Center (ARC)
6An Overview of IP for Monitoring
- Telco Dialer Model
- Transmission can take gt1 minute end-to-end
- Monitoring stations usually pay for 800 numbers
(or even local calls) for the panels to dial in - Cost passed to end users in fees typically on a
per call basis - Comm failures are not detected by the monitoring
station until a 24 hour test signal is lost - Not compatible with VoIP scenarios
7An Overview of IP for Monitoring
- Easy to install
- Fits right inside or right beside the panel
- Fast programming and simple interfaces
- Can set up at the office and transport to the job
site - Programs via laptop/desktop
- It answers any phone number dialed by the panel
so no panel changes required
8An Overview of IP for Monitoring
- None of the private radio network problems
- Large investment for a capable radio network
- Best in metro/city where accounts are close
- At network fringe, finding multiple paths
difficult - Panel is relying on the integrity of the accounts
around them to relay messages. - Some radio systems use the Fire panel printer
output as the connection means. - Printer output is not expected in the critical
alarm communications path - Software updates may alter Printer output
9An Overview of IP for Monitoring
- This is a business building opportunity for
installers - The savings in phone line charges will pay for
the installation - Its a source of new work for installers
10IP Solutions - IP Communicator
- The IP communicator module allows NOTIFIER panels
to use a customers existing IP network as a
communication path to transmit alarms - It offers performance, functionality
enhancements, and cost savings to traditional
digital dialer communicators
11IP Solutions - IP Communicator
- Full bi-directional access to the alarm panel
over the internet - No third party access to information (latest 512
bit encryption) - No geographic limitations (UD operator can be
anywhere) - Supervision is outstanding every 90 seconds
- Works with any fire panel
- Remote Diagnostics allows troubleshooting from
any connected PC
12IP Solutions - IP Communicator
IPDACT-2 IPDACT-2UD
12
13IP Solutions VisorAlarm Receiver
- Central station Teldat IP receiver
- Top quality turn key IP solution with Teldats
experience and expertise - Plug and play with any automation software
- UL listed for fire and security
- Emulates existing popular receivers
14IP Solutions VisorAlarm Receiver
- The IP receivers are synchronized to each other
for immediate backup turnover - Subscriber data is stored/backed up to a smart
card - Allows a replacement to be put back into service
within 30 seconds - IP Receivers are very robust not a patch to
existing telephone receivers but designed
specifically for IP alarm monitoring
15IP Solutions VisorAlarm Receiver
Serial port 2
Alarm printer
Ethernet port
Internet
Automation Server
Serial port 1
- Teldat IP receiver emulates a conventional phone
receiver - Ademco 685
- Radionics 6500
- Surgard MLR2000 / MLR2D
- Serves IP Alarms generated by Contact-ID Alarm
Panels - Supervises the IP Link to each registered account
- Supports Upload / Download over IP (to select
FACPs)
16IP Solutions System Integrity
- Provision for disaster recovery
- Based on the architecture of IP receivers, remote
duplicate receivers can be located anywhere! - If a site is brought down for any reason, (fire,
flood, etc.) a remote site can provide immediate
switch over - IP receivers permit duplicate monitoring for
troubles by an end user or alarm dealer for
better service to end user subscribers
17IP Solutions - Secure Access
- Confidentiality
- All exchanged IP traffic is encrypted in AES-512
- Meets and exceeds SIA IP specification-512 bit
Advanced Encryption Standard (AES) - Anti-replay protection, man-in-the-middle
protection - The VisorALARM only serves registered IP
Communicators - The registration process is password protected
- IP Communicator programming access is password
protected - The VisorALARM programming is user and password
protected - Three user access levels
- Anti-device substitution
- IP Communicator registers into the VisorALARM
during installation with unique and non-writable
information
18IP Solutions Central Station Application
Alarm L1D005
FACP with DACT
Contact ID
IP Receiver
IP Router
EIA-232
IP Communicator
Smoke Alarm 2nd Fl. Hallway Acct 4321 XYZ
Co. 555 Main St
World Wide Web
IP Router
Customer Network
19IP Solutions Proprietary System Application
Alarm L1D005
FACP with DACT
Contact ID
IP Receiver
IP Router
EIA-232
IP Communicator
World Wide Web
IP Router
Customer Network
20Code Compliance - NFPA
- IP Communicator meets all requirements for a
single communication line - Allowed by NFPA72-2007
- Under 8.6.4 Other Communications Technologies
- Allowed by NFPA72-2010
- Under 26.6.2.2 Alternative Methods
- No redundant path required
- Alarm transmission meets the 500 sec reporting
requirement - Instant reporting of connection loss
- Keep alive polling increases line security from
once every 24 hours to once every 90 seconds
21Code Compliance - UL
- UL 864 listing of IP Communicator meets the
requirements in NFPA 72 for Internet/Intranet
fire alarm communications - Permits the IP Communicator to operate on a
single communications line to a central station
equipped with UL 864 listed VISORALARM-PLUS IP
receivers - Without requirement for a backup/redundant
communications line - For UL listing found on the UL web site
- http//database.ul.com/cgi-bin/XYV/template/LISEXT
/1FRAME/index.htm
22Compatible Fire Alarm Systems
- IPDACT is UL 864 Ninth Edition Listed with the
following panels - NFS-320
- NFS2-640
- NFS2-3030
- NCA-2
- NFW-50
- NFW2-100
- SFP-5UD
- SFP-10UD
- 411UDAC/411UD
- Requires the IPDACT-2
23Compatible Fire Alarm Systems
- IPDACT can be used with the following panels in
retrofit applications - NFS-3030
- NFS-640
- NCA
- AFP1010/AM2020
- AFP-300/400
- AFP-200
- AFP-100
- System 5000
- System 500
- SFP-1024
- Requires the IPDACT-2
24Non-NOTIFIER Panel Monitoring
- The 411, 411UD or 411UDAC dialers are UL listed
for use with the IP Communicator - The 411 series dry contact inputs are connected
to the Alarm, Trouble, and Supervisory relay
outputs of any panel - The IPDACT connects to PH-1,PH-2 outputs of the
411 series products
25Central Stations that Support IP Comm.
- Affiliated Central
- Alarm Tech Central Service
- AlarmWatch
- AmerX Security
- Bay Alarm
- Blue Ridge Security Systems
- C.O.P.S Monitoring
- Devcon Security Services
- Emergency Systems Inc. (ESI)
- EMERgency24
- ESC Central
- Monitoring Center (NMC)
- Rapid Response
- Security Central
- Southwest Dispatch Center
- United Central Control (UCC)
- USA Central Station
26IP Communicator Summary
- Saves high cost of phone lines and meets NFPA
requirements - Higher line security (every 90 seconds vs. once a
day) - Provides non-hackable security via 512 bit AES
encryption - Supports either static IP or dynamic IP
- Optional, simultaneous dual alarm monitoring at
end users location using maintenance receiver - Easy to program and uses customers existing
shared network equipment
27Questions?
- Please submit your questions by typing them into
the questions box on the right side of your
screen
28 Thank you! A recording of todays webinar will
be posted on www.magni-fire.com
29 www.honeywell.com