PUWER - PowerPoint PPT Presentation

About This Presentation
Title:

PUWER

Description:

PUWER Which legislation applies? Product Directives New machines/equipment Even if for own use New assemblies of machines New or old machines Old machines imported ... – PowerPoint PPT presentation

Number of Views:3209
Avg rating:3.0/5.0
Slides: 39
Provided by: MARTINJ85
Category:

less

Transcript and Presenter's Notes

Title: PUWER


1
CE
  • PUWER

2
Which legislation applies?
Product legislation Free movement of goods
Employment legislation Employee protection
3
Product Directives
  • New machines/equipment
  • Even if for own use
  • New assemblies of machines
  • New or old machines
  • Old machines imported into EEA
  • Significantly modified machines/equipment

4
Supplying new machinery
  • Manufacturers duties
  • Design for safety
  • Eliminate hazards
  • Produce TCF
  • Write manual
  • Issue declaration of conformity
  • Fix CE mark
  • Purchaser

5
UK HS Regulations
  • Health and Safety at Work Act
  • Management of health safety at work
  • Workplace health safety welfare
  • Provision and use of work equipment (PUWER)
  • Manual handling
  • Display screen work
  • Personal protection equipment
  • COSHH
  • Noise
  • Electricity at Work
  • Construction Design Management CDM
  • Lifting operations lifting equipment

6
PUWER 98
  • Use of Work Equipment Directive 89/655/EEC
  • Enacted in the UK by
  • The Provision Use of Work Equipment Regulations
    1998
  • Applied employers providing equipment for their
    employees to use
  • Introduced 1st January 1993
  • Amended 1st January 1998

7
PUWER 98
  • Regulations 1-3
  • Procedural
  • Regulations 5-9
  • 4 - Suitablility of work equipment
  • 5 - Maintenance
  • 6 - Inspection
  • 7 - Specific risks
  • 8 - Information and instructions
  • 9 - Training
  • new requirement

8
Suitability of work equipment
  • PUWER 98 Regulation 4
  • Every employer shall ensure that work equipment
    is so constructed or adapted as to be suitable
    for the purpose for which it is used or provided

9
Maintenance
  • PUWER 98 Regulation 5
  • ensure that work equipment is maintained in an
    efficient state, in efficient working order and
    in good repair
  • Ensure that where any machinery has a maintenance
    log the log is kept up to date

10
What is maintenance?
11
Are these maintenance ?
  • Adjustments ?
  • Servicing?
  • Lubrication?
  • Cleaning?
  • Inspection?
  • Overhaul?
  • Repair?
  • Minor modification?
  • Software changes?
  • Major modification?
  • Redesign?

12
Inspection
  • PUWER 98 Regulation 6
  • Where safety depends on installation conditions
  • If exposed to conditions causing deterioration
    which is liable to result in dangerous situations
  • Exceptional circumstances

13
Inspection
  • PUWER 98 Regulation 6
  • Ensure the results of and inspection is recorded
    and kept until the next inspection
  • Ensure equipment is accompanied by physical
    evidence of the inspection if moved from one
    undertaking to another

14
Conformity to EU legislation
  • PUWER 98 Regulation 10
  • Obligation to choose CE marked equipment
  • Obligation to check that CE mark is valid
  • new requirement

15
PUWER 98
  • Measures to bring pre CE equipment up to standard
  • 11 - Dangerous parts of machines
  • 12 - Protection against specific hazards
  • 13 - High or very low temperatures
  • 14 - Controls for starting making a
    significant change
  • 15 - Stop controls
  • 16 - Emergency stop controls
  • 17 - Controls
  • 18 - Control systems
  • 19 - Isolation from sources of energy

16
PUWER 98
  • Measures to bring pre CE marked machines up to
    standard
  • 20 - Stability
  • 21 - Lighting
  • 22 - Maintenance operations
  • 23 - Markings
  • 24 - Warnings

17
PUWER 98
  • Regulations 25-30
  • Mobile Equipment
  • Regulations 31-35
  • Power presses
  • Regulations 36-39
  • Procedural
  • new requirements

18
What about modifications?
19
  • Modifications that are part of maintenance
  • Covered by PUWER 98
  • No risk assessment
  • No documentation
  • No CE

20
Mechanical modifications
  • PUWER
  • Any activity described in the manual
  • Replacing like components with like
  • Repairs to bring machine back to its original
    condition
  • Strengthening assemblies
  • Strengthening guards

21
Electrical modifications
  • PUWER
  • Any activity described in the manual
  • Replacing components with like components
  • Lowering rating of fuses or MCBs
  • Adding e-stops
  • Adding interlocking devices

22
Software modifications
  • PUWER
  • Any modification described in the manual

23
Changes of Use
  • PUWER
  • Any use described in the manual

24
Other modifications
  • Carry out risk assessment
  • Will the existing design be suitable/safe when
    the the proposed modification has taken place?

25
Risk Assessment
  • Management of Health and Safety at work
    Regulation 3
  • Every employer shall make a suitable and
    sufficient assessment of risks to
  • a) employees
  • b) persons not in his employment arising out of
    or in connection with the conduct by him of his
    undertaking
  • Introduced 1st January 1993

26
(No Transcript)
27
Electrical modifications
  • MHSWR/PUWER
  • Adding assemblies not described in the manual
    e.g. an inverter
  • Small alterations to the circuit diagram

28
Software modifications
  • MHSWR/PUWER
  • Any modification not described in the manual

29
Assembly modifications
  • MHSWR/PUWER
  • Change of use of assembly
  • Handling new food product
  • Rearranging independently controlled machines

30
Changes of Use
  • MHSWR/PUWER
  • Uses similar to those described in the manual

31
Significant modifications
  • Modification compromises original equipment
    design
  • Considered as new machines

32
What is a significant modification?
33
Mechanical modifications
  • Machinery Directive
  • Adding assemblies not in manual
  • Replacing components with ones that work in a
    different way

34
Electrical modifications
  • Machinery Directive
  • Adding assemblies not described in the manual
    e.g. an inverter
  • Replacing components with others that work in a
    different way e.g. relays with a PLC
  • Altering circuit diagram significantly

35
Software modifications
  • Machinery Directive
  • Any modification that could compromise the safety
    of the the machine

36
Assembly modifications
  • Machinery Directive
  • Significant change of use of assembly
  • Modifications to machines to create assembly

37
Changes of Use
  • Machinery Directive
  • Uses specifically excluded in the manual

38
Modifications
  • Maintenance covered by PUWER
  • Risk Assessment covered by MHSWR
  • Modification treated as new machines/equipment
  • Modification covered by PUWER
  • Documentation covered by PUWER and MHSWR
Write a Comment