Isoelectric Focusing Fundamental of Bioprocess Engineering Laboratory - PowerPoint PPT Presentation

1 / 22
About This Presentation
Title:

Isoelectric Focusing Fundamental of Bioprocess Engineering Laboratory

Description:

The proteins that are to be used: Ovalbumin. Casein. Gluten. Theoretical Background ... Gluten = 7.64. Blank result in our film. Possible problems. Solutions ... – PowerPoint PPT presentation

Number of Views:1624
Avg rating:3.0/5.0
Slides: 23
Provided by: xxx3154
Category:

less

Transcript and Presenter's Notes

Title: Isoelectric Focusing Fundamental of Bioprocess Engineering Laboratory


1
Isoelectric FocusingFundamental of Bioprocess
Engineering Laboratory
  • Sally Lai
  • Eric Guo
  • Jerry Yin

2
Aim of experiment
  • To fractionise proteins using an electrophoretic
    technique according to their isoelectric point
    (pI) along a continuous pH gradient.
  • The proteins that are to be used
  • Ovalbumin
  • Casein
  • Gluten

3
Theoretical Background
  • What are Proteins?
  • Net charges
  • Isoelectric point
  • Isoelectric Focusing

4
Proteins
  • A chain of amino acids
  • Amphoteric molecules they carry either positive,
    negative or zero net charges
  • pH dependant for the net charge

5
Net Charge
  • Net charge of protein is the sum of all the
    negative and positive charges of its amino acid
    side chains and amino- and carboxyl- termini

6
Isoelectric Point (pI)
  • The point where the protein has a net charge of
    zero (that is, the sum of the negative and
    positive charges equal to zero)
  • Reached only when the pH pI, as shown in the
    previous diagrams.

7
Isoelectric Focusing (IEF)
  • Is a protein purification and fractionation
    technique
  • Concentrates proteins at their pIs and allows
    proteins to be separated on the basis of very
    small charge differences
  • The separation occurs only under the influence of
    an electric field

8
Process of running IEF
  • Prepare the solutions
  • Prepare the sample and the protein standard into
    applicator
  • PhastSystem operations
  • Collect results

9
Prepare the solutions
  • Urea solution
  • The washing solution (30 methanol, 10 (v/v)
    acetic acid)
  • The stock solution (0.2 (w/v), 200mL)
  • The fixing solution (20 (v/v) 25mL
    trichloroacetic acid) toxic!!
  • The final stage solution (0.1 (w/v) CuSO4 over
    mixture of washing solution and stock solution)
  • Final IEF solution (to be used fresh)

10
Prepare the samples
  • Dissolve proteins into prepared Urea solutions
  • Fill the samples and standards to the 8
    depressions on the Parafilm (2 for each)
  • Load sample applicator

11
PhastSystem operations
  • Place two gels onto the separation bed, remove
    plastic film
  • Insert the applicator
  • Run the sample with the PhastSystem programmed
    operations
  • Remove the gel into fresh final solution for
    staining.

12
Results
  • Experimental Failure no results appeared for the
    3 runs.
  • Sample results are used instead for calculations

13
Sample results
14
Useful data
15
Solving the problem
Run 1a y 0.855x - 2.0364
Run 1b y 0.8635x - 2.0408
16
Discussion
  • Theoretical PI point
  • Ovalbumin 5.19
  • Casein 4.98
  • Gluten 7.64
  • Blank result in our film
  • Possible problems

17
Solutions
  • Protein solutions
  • Protein solubility
  • Protein purity
  • Solvent
  • Stain solutions
  • Fix solution

18
Equipment
  • Equipment set up
  • Insufficient electrodes cleaning
  • Poor contact between electrode and gel
  • Dropping of Applicator arm
  • Damage of contact block and pin
  • PhaseSystem operate and programming problem
  • Bent applicator
  • Insufficient power/time

19
Cooling problem
  • PI point of protein is temperature dependant.
  • The performance of coolant will affect the mark
    positions. (May result the marks will be out of
    gels visible range)

20
Conclusion
  • Unexpected results occurred
  • Possible reasons
  • Solutions prepare
  • Equipments
  • Procedure

21
Recommendations
  • Use better buffer such as acid or detergent
    buffer to improve the proteins solubility
  • Prevent possible protein denature.
  • more accurate concentration.
  • Make the final solution and fix solution fresh

22
Recommendations (con.)
  • Use the equipment (PhastSystem) after it has been
    tested and prove the machine work as expect.
  • Program different and appropriate methods of IEF
    PhastSystem.
  • Make better experiment plan and implement
    accordingly.
  • Use more time to study the theory of the
    experiment before rush into lab work
Write a Comment
User Comments (0)