Integrated Room Pressure Control Solutions for - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

Integrated Room Pressure Control Solutions for

Description:

No Special Set Up Tools Required. UL Listed. Complies with ... University of Northern Iowa, Cedar Rapids, IA. New Jersey Institute of Technology, Clifton, NJ ... – PowerPoint PPT presentation

Number of Views:141
Avg rating:3.0/5.0
Slides: 14
Provided by: tria
Category:

less

Transcript and Presenter's Notes

Title: Integrated Room Pressure Control Solutions for


1
Integrated Room Pressure Control Solutions for
2
FMS 1630 Series Room Pressure Controller
  • Stand Alone Controller
  • N2 direct connect
  • Monitor Only Mode
  • UL Listed
  • Adjustable Alarm Setpoints
  • Easy to Read
  • Thru the Wall Sensing
  • Audible and Visual Alarms

3
FMS 1600 Series Room Pressure General Exhaust
Controller Applications
  • Hospital TB Isolation Rooms
  • Operating Rooms
  • Research and Teaching Laboratories
  • Clean Rooms
  • Pharmaceutical Manufacturers
  • Nursing Homes
  • Correctional Facilities
  • Printing Plants
  • Any Area Requiring Isolation of Contaminants

4
FMS 1600 Series Room ControllerStandard Features
  • N2 Direct - Compatibility with no Integrator
    needed
  • Room pressure Monitoring and Control
  • High Accuracy and Repeatable Thru the Wall Flow
    Sensing
  • Patented Ultra-Sensitive Thermal Anemometer
  • Negative, Positive or No Isolation Modes
  • Adjustable Alarm Set Points
  • Audible and Visual Alarms whenRoom is Unsafe
    Showing Safe, Cautionand Alarm Conditions
  • No Special Set Up Tools Required
  • UL Listed
  • Complies with CDC Guidelines

5
FMS 1600 Series Room ControllerStandard Features
(continued)
  • Easy to Use by Customers Staff
  • Flexibility
  • Ideal for Remote Sensor Locations
  • Display of Pressure to 5 Digits
  • Display Pressure Reading in English or Metric
    Units
  • Display Includes Location Description, i.e. Lab
    141, Room 1320
  • Precision Floating Point Measurement, 12 Bit
    Accuracy

6
System Architecture with Metasys
Metasys Operator Workstation can control and
monitor TRIATEK FMS-1630
N1
Johnson Controls N1
Johnson Controls N2
JCI VAV Controller
JCI Network Control Module
JCI AHU Controller
TRIATEK FMS-1630 Controller
TRIATEK FMS-1630 Monitor
7
TRIATEK Pressure Independent Venturi Air Valves
  • Material
  • Stainless Steel
  • Aluminum
  • Heresite Coating
  • Sizes
  • 6,8,10,12,16
  • Actuator Options
  • Pneumatic
  • Electric

8
TRIATEK Sound Attenuated Pressure Independent
Venturi Air Valves Options
  • Material
  • Aluminum
  • Sizes
  • 6,8,10,12,16
  • Group Valves for Larger Requirements
  • Actuator
  • Pneumatic
  • Electric

9
TRIATEK Fast Acting Actuator
  • Fast Acting Electronic Actuator
  • Analog Input
  • Stroke Time
  • 33ms/Degree of Rotation
  • Typical Control Stroke
  • 10o to 20o
  • 0.3 to 0.6 sec.
  • Torque
  • 35 in. lb.

10
TRIATEK HMS-1600 Series Fume Hood Controller
Sample Installations
  • Nestle Research Development, New Milford, CT
  • Lederle Labs, Pearl, NY
  • Warner Lambert Park Davis, Morristown, NJ
  • Georgetown University, Washington, DC
  • Roanoke College, Roanoke, VA
  • University of Northern Iowa, Cedar Rapids, IA
  • New Jersey Institute of Technology, Clifton, NJ
  • VA Medical Center, Waco, TX
  • University of Alabama, Birmingham, AL
  • Center for Forensic Science, Hauppauge,New York
    (Worlds Largest)

11
TRIATEK FMS-1600 SeriesSample Installations
  • Center for Disease Control and Prevention,
    Atlanta, GA
  • St Josephs Hospital, Atlanta, GA
  • Georgetown University, Washington, DC
  • VA Medical Center, Battle Creek, MI
  • Broward General Medical Center, Ft Lauderdale, FL
  • St Francis Medical Center, Honolulu, HI
  • St Joseph Health Center, London Ontario, Canada
  • Scottsdale Memorial Hospital, Scottsdale, AZ
  • University Hospital, San Antonio, TX
  • BASF Corporation, Lavonia, MI
  • Charles River Corporation, Monona, IA
  • Linvatec Corporation, Tampa, FL

12
TheRoom Pressure Control SolutionTo Meet The
Customers Need
13
Johnson Controls
Write a Comment
User Comments (0)
About PowerShow.com