Title: CLASSES OF FIRE
1CLASSES OF FIRE
- Class A combustible materials
- Characteristics deep seated, leave ash and
embers. - Extinguishing method cooling
- Class B flammable liquid, gases, greases and
similar products. - Characteristic surface burning.
- Extinguishing method cut off oxygen supply or
prevent flammable vapor from being given off. - Class C electrical fires
- Characteristic electrical shock
- Extinguishing method use non-conducting
extinguishing agent. - Class D combustible metal fires
2Types of Portable Fire Extinguishers
Different types of fire extinguishers are
designed to fight different types of fires. The
three most common types of fire extinguishers
are
- Air pressurized water extinguishers
- Carbon Dioxide extinguishers
- Dry Chemical Extinguishers
3Air-pressurized water extinguishers
4Air-pressurized water extinguishers
- Water is one of the most commonly used
extinguishing agents for type A fires. They are
filled about two-thirds of the way with ordinary
water, then pressurized with air. In some cases,
detergents are added to the water to produce a
foam. They stand about two to three feet tall and
weigh approximately 25 pounds when full. - APWs extinguish fire by cooling the surface of
the fuel to remove the "heat" element of the fire
triangle. - APWs are designed for Class A (wood, paper,
cloth, rubber, and certain plastics) fires only.
5Air-pressurized water extinguishers
- Never use water to extinguish flammable liquid
fires. Water is extremely ineffective at
extinguishing this type of fire and may make
matters worse by the spreading fire. - Never use water to extinguish an electrical fire.
Water is a good conductor and may lead to
electrocution if used to extinguish an electrical
fire. Electrical equipment must be unplugged
and/or de-energized before using a water
extinguisher on an electrical fire.
6Carbon Dioxide extinguishers
7Carbon Dioxide extinguishers
- This type of extinguisher is filled with Carbon
Dioxide (CO2), a non-flammable gas under extreme
pressure. These extinguishers put out fires by
displacing oxygen, or taking away the oxygen
element of the fire triangle. Because of its high
pressure, when you use this extinguisher pieces
of dry ice shoot from the horn, which also has a
cooling effect on the fire. You can recognize
this type of extinguisher by its hard horn and
absent pressure gauge. - CO2 cylinders are red and range in size from five
to 100 pounds or larger. - CO2 extinguishers are designed for Class B and C
(flammable liquid and electrical) fires only.
8Carbon Dioxide extinguishers
- CO2 is not recommended for Class A fires because
they may continue to smolder and re-ignite after
the CO2 dissipates. - Never use CO2 extinguishers in a confined space
while people are present without proper
respiratory protection.
9Dry Chemical extinguishers
10Dry Chemical extinguishers
- Dry chemical extinguishers put out fires by
coating the fuel with a thin layer of fire
retardant powder, separating the fuel from the
oxygen. The powder also works to interrupt the
chemical reaction, which makes these
extinguishers extremely effective. - Dry chemical extinguishers are usually rated for
class B and C fires and may be marked multiple
purpose for use in A, B, and C fires. They
contain an extinguishing agent and use a
compressed, non-flammable gas as a propellant. - Dry Chemical extinguishers will have a label
indicating they may be used on class A, B, and/or
C fires.
11HCFC extinguishers
- Ideal for all classes of fire (A,B,C)
-
- Non-expirable. No need for yearly refill.
- Non-corrosive.
- Non-residual. Not messy to use.
- Multi-shot. Can be used for several times.
- Stop combustion chemically and directly without
powder, foam or water.
12How Fire Extinguishers Work?
Portable fire extinguishers apply an
extinguishing agent that will either cool burning
fuel, displace or remove oxygen, or stop the
chemical reaction so a fire cannot continue to
burn. When the handle of an extinguisher is
compressed, it opens an inner canister of
high-pressure gas that forces the extinguishing
agent from the main cylinder through a siphon
tube and out the nozzle.
13 Care and Maintenance of Your
Extinguisher At least once a month you should
inspect your extinguisher. Ensure that
- The extinguisher is not blocked by objects that
could interfere with access in an emergency. - The labels are readable.
- The pressure is at the recommended level.
- The nozzle or other parts are not obstructed.
- The pin and tamper seal (if it has one) are
intact. - There are no dents, leaks, rust, chemical
deposits and other signs of abuse/wear. - Some manufacturers recommend shaking your dry
chemical extinguishers to prevent the powder from
settling/packing. - Fire extinguishers should be pressure tested (a
process called hydrostatic testing) after a
number of years to ensure that the cylinder is
safe to use.
If the extinguisher is damaged or needs
recharging, get it replaced immediately! Recharge
all extinguishers immediately after use
regardless of how much they were used.
14Following the P.A.S.S Technique
15Following the P.A.S.S Technique
Pull Pull the pin. This will also break the
tamper seal.
If you have the slightest doubt about your
ability to fight a fireEVACUATE IMMEDIATELY!
16Following the P.A.S.S Technique
Aim Aim low, pointing the extinguisher nozzle
(or its horn or hoses) at the base of the fire.
If you have the slightest doubt about your
ability to fight a fireEVACUATE IMMEDIATELY!
17Following the P.A.S.S Technique
Squeeze Squeeze the handle so that it will
release the extinguishing agent.
If you have the slightest doubt about your
ability to fight a fireEVACUATE IMMEDIATELY!
18Following the P.A.S.S Technique
Sweep Sweep from side to side at the base of
the fire until the extinguisher is completely
empty assuring that the fire is out.
If you have the slightest doubt about your
ability to fight a fireEVACUATE IMMEDIATELY!
19Fire extinguishers can represent an important
segment of any overall fire protection program.
However, their successful functioning depends
upon the following conditions having been met
- (a) The fire extinguisher is properly located and
in working order. - (b) The fire extinguisher is of the proper type
for a fire that can occur. - (c) The fire is discovered while still small
enough for the fire extinguisher to be effective. - (d) The fire is discovered by a person ready,
willing, and able to use the fire extinguisher.
20In The Event of Fire
F
ind
I
nform
R
eact
E
xtinguish