Title: DVS CAP


1
DVS CAP Secure Configuration Drawing
(Example) (Replace this header with your Site ID)
NOTE This Configuration is only authorized with
proper isolation integrated within the A/B
Switch, such as optical isolation. (See the
current list on the Approved Equipment page.)
BLDG/ROOM
A / B
A / B
Brand X CODEC
Brand X IMUX
RS-449 or EIA-530
RS-449 or EIA-530
(Dial From the CODEC)
PRI or 3BRI
KIV
RS-366
RS-366
Dial Isolation Module
LEC or DSN Switch
BLDG/ROOM
Mic
BLDG/ROOM
Monitor
PC
RED EQUIPMENT BAY
BLACK EQUIPMENT BAY
All Configuration Drawings must include the Make
and Model of the CODEC, IMUX, Dial Isolator, and
all switches. This information is required prior
to processing your request for service or renewal
of service. The VTF connectivity diagram must
include all associated devices including video
equipment, MCUs, line interface units, hubs, IP
connections, routers, firewalls, gateways,
modems, encryption devices, backup devices, type
of transport, bandwidth being utilized, your Site
ID, and building / room locations of all
equipment. (PLEASE REMOVE THIS TEXT BOX PRIOR TO
SUMISSION.)
2
DVS CAP Secure Configuration Drawing
(Example) (Replace this header with your Site ID)
NOTE This Configuration is only authorized with
proper isolation integrated within the A/B
Switch, such as optical isolation. (See the
current list on the Approved Equipment page.)
BLDG/ROOM
A / B
A / B
Brand X CODEC
RS-449 or EIA-530
RS-449 or EIA-530
Brand X IMUX
PRI or 3BRI
KIV-7
LEC or DSN Switch
(Dial ONLY From the IMUX)
BLDG/ROOM
Mic
BLDG/ROOM
Monitor
PC
BLACK EQUIPMENT BAY
RED EQUIPMENT BAY
All Configuration Drawings must include the Make
and Model of the CODEC, IMUX, Dial Isolator, and
all switches. This information is required prior
to processing your request for service or renewal
of service. The VTF connectivity diagram must
include all associated devices including video
equipment, MCUs, line interface units, hubs, IP
connections, routers, firewalls, gateways,
modems, encryption devices, backup devices, type
of transport, bandwidth being utilized, your Site
ID, and building / room locations of all
equipment. (PLEASE REMOVE THIS TEXT BOX PRIOR TO
SUMISSION.)
3
DVS CAP Secure Configuration Drawing
(Example) (Replace this header with your Site ID)
UNCLASS PATH
F / M
F / M
(Fiber Modem)
(Fiber Modem)
BLDG/ROOM
A / B
A / B
Brand X CODEC
Brand X IMUX
RS-449 or EIA-530
RS-449 or EIA-530
(Dial From the CODEC)
PRI or 3BRI
KIV
(KIV-7,or KIV-19)
RS-366
RS-366
LEC or DSN Switch
BLDG/ROOM
Dial Isolation Module
Mic
BLDG/ROOM
Monitor
Fiber Modems Must Extend RS-449 or
EIA-530 Handshaking Signals in Addition to Data
PC
BLACK EQUIPMENT BAY
RED EQUIPMENT BAY
All Configuration Drawings must include the Make
and Model of the CODEC, IMUX, Dial Isolator, and
all switches. This information is required prior
to processing your request for service or renewal
of service. The VTF connectivity diagram must
include all associated devices including video
equipment, MCUs, line interface units, hubs, IP
connections, routers, firewalls, gateways,
modems, encryption devices, backup devices, type
of transport, bandwidth being utilized, your Site
ID, and building / room locations of all
equipment. (PLEASE REMOVE THIS TEXT BOX PRIOR TO
SUMISSION.)
4
DVS CAP Secure Configuration Drawing
(Example) (Replace this header with your Site ID)
(Patch KIV-7 into path for Classified
remove/replace with UNCLASS patch for
Unclassified.)
BLDG/ROOM
P / P
P / P
Brand X CODEC
RS-449 or EIA-530
RS-449 or EIA-530
Brand X IMUX
PRI or 3BRI
KIV-7
(Patch Panel)
(Patch Panel)
LEC or DSN Switch
Dial From IMUX
BLDG/ROOM
Mic
BLDG/ROOM
Monitor
PC
BLACK EQUIPMENT BAY
RED EQUIPMENT BAY
All Configuration Drawings must include the Make
and Model of the CODEC, IMUX, Dial Isolator, and
all switches. This information is required prior
to processing your request for service or renewal
of service. The VTF connectivity diagram must
include all associated devices including video
equipment, MCUs, line interface units, hubs, IP
connections, routers, firewalls, gateways,
modems, encryption devices, backup devices, type
of transport, bandwidth being utilized, your Site
ID, and building / room locations of all
equipment. (PLEASE REMOVE THIS TEXT BOX PRIOR TO
SUMISSION.)
5
DVS CAP Secure Configuration Drawing
(Example) (Replace this header with your Site ID)
(Patch KIV-7 into path for Classified -/-
Remove/replace with UNCLASS patch for
Unclassified.)
BLDG/ROOM
(Patch Panel)
(Patch Panel)
P / P
P / P
Brand X CODEC
RS-449 or EIA-530
Brand X IMUX
RS-449 or EIA-530
(Dial From the CODEC)
PRI or 3BRI
KIV
RS-366
RS-366
Dial Isolation Module
LEC or DSN Switch
BLDG/ROOM
Mic
BLDG/ROOM
Monitor
PC
RED EQUIPMENT BAY
BLACK EQUIPMENT BAY
All Configuration Drawings must include the Make
and Model of the CODEC, IMUX, Dial Isolator, and
all switches. This information is required prior
to processing your request for service or renewal
of service. The VTF connectivity diagram must
include all associated devices including video
equipment, MCUs, line interface units, hubs, IP
connections, routers, firewalls, gateways,
modems, encryption devices, backup devices, type
of transport, bandwidth being utilized, your Site
ID, and building / room locations of all
equipment. (PLEASE REMOVE THIS TEXT BOX PRIOR TO
SUMISSION.)
6
DVS CAP Secure Configuration Drawing
(Example) (Replace this header with your Site ID)
F / M
F / M
(Fiber Modem)
(Fiber Modem)
(Patch KIV-7 into path for Classified -/-
Remove/replace with UNCLASS patch for
Unclassified.)
BLDG/ROOM
P / P
Brand X CODEC
RS-449 or EIA-530
P / P
Brand X IMUX
RS-449 or EIA-530
(Dial From the CODEC)
PRI or 3BRI
KIV
(Patch Panel)
(Patch Panel)
RS-366
RS-366
Dial Isolation Module
LEC or DSN Switch
BLDG/ROOM
Mic
BLDG/ROOM
Monitor
PC
BLACK EQUIPMENT BAY
RED EQUIPMENT BAY
All Configuration Drawings must include the Make
and Model of the CODEC, IMUX, Dial Isolator, and
all switches. This information is required prior
to processing your request for service or renewal
of service. The VTF connectivity diagram must
include all associated devices including video
equipment, MCUs, line interface units, hubs, IP
connections, routers, firewalls, gateways,
modems, encryption devices, backup devices, type
of transport, bandwidth being utilized, your Site
ID, and building / room locations of all
equipment. (PLEASE REMOVE THIS TEXT BOX PRIOR TO
SUMISSION.)