Title: Knick Elektronische Megerte GmbH
1KnickElektronische MeßgeräteGmbH Co.
2Product Range
3Turnover 2005 by Product Lines
41 Mio USD
4Product Mix Interface Modules
5Product Mix Interface Modules
strong
weak
growing
strong
strong
6Market Size Estimation
7Market Situation
- large suppliers of automation products
(Rockwell, Siemens, etc.) - specialized suppliers of interface
products(Knick, Dataforth, Action
Instruments/Eurotherm/Invensys, etc. ) - several small manufacturers / suppliers
- dozens of models / variants
- high-quality to shady products
- discriminating customers and buyers of
convenience products (in bundles with other
products or systems) -
8Knick's Product Philosophy
- Knick products stand for
- high-performance products, thorough design
withstanding extreme conditions - reliable - with 5 years of warranty
- general application and specialized
productsstandard signal isolators to
high-voltage isolators, - broad range of analog signal isolators for
safe-area applications -
9Why use Galvanic Isolation?
10Signal Conditioning / Transmission
- Factory Automation
- Process Automation
- Power Plants
- Railway Systems
- Ships
- Machines
- .....
11Application
- Example magnetic levitation train in Shanghai
Knick isolators (VariTrans) are used for signal
conditioning.
12Application
- Example magnetic levitation train in Berlin
13Basics
- Isolator Functions
- Transmit / amplify / convert analog
electrical signals
Out
In
0...20 mA4...20 mA0...10 V/- 60 mV/- 90
mV/-150 mV0...100 mA0...30 V0...1000 V...
0...20 mA4...20 mA0...10 V/- 20 mA/- 10 V
- standard signals- bipolar signals- shunt
voltages- power supply voltages- TC voltages-
RTD and other resistors- ...
14Basics
- Isolator Functions
- Transmit / amplify / convert analog
electrical signals - Cut direct (galvanic) electrical connection,
i.e. isolate
Out
In
15Basics
- Isolator Functions
- Transmit / amplify / convert analog
electrical signals - Cut direct (galvanic) electrical connection,
i.e. isolate - auxiliary power
Out
In
Power 24V DC ... 230 V AC
16Basics
- Manufacturing or processing plant
CONTROL ROOM
FIELD
control signals
Control System
measurement signals
8888
recorder
indicator
17Basics
Motor current measurement
18Basics
- Important properties of isolation amplifiers
- input / output range (switchable?)
- precision / transmission error
- isolation (working voltage, test voltage)
- power supply
- other characteristics, depending on application
- cut-off frequency
- common-mode rejection
- output load
- ...
19Electronic Design Know-How
- "Hidden" product characteristics
- temperature coefficient
- common mode rejection
- zero-point behavior
- oversteer behavior
- EMC
20Electronic Design Know-How
21Electronic Design Know-How
temperature coefficient
50 ppm/K (0.005
/K) expected temperature in a cabinet 50
C 50 C - 23 C (?ref.)
27 C 27 K x 50 ppm/K 1350
ppm
1350 ppm x 20 mA
27 µA
temperature error 0.14
22Electronic Design Know-How
temperature coefficient
300 ppm/K (0.03
/K) expected temperature in a cabinet 50
C 50 C - 23 C (?ref.)
27 C 27 K x 300 ppm/K
8100 ppm
8100 ppm x
20 mA 162 µA
temperature error 0.8
23Electronic Design Know-How
- 50 Hz common-mode rejection
24Electronic Design Know-How
standard isolator -0.25 to 1 standard
isolator 1 to - 0.25 Knick 1 to - 0.25
and -0.25 to 1
25Electronic Design Know-How
26Electronic Design Know-How
27Electronic Design Know-How
28Electronic Design Know-How
- "Hidden" product characteristics
- temperature coefficient
- common mode rejection
- zero-point behavior
- oversteer behavior
- EMC
Safe operation must be guaranteed for all
circumstances
29Electronic Design Know-How
- Mean Time Between Failures MTBF low number of
components thorough selection of components
long-term electronic design experience - e.g. VariTrans B 10 000
- MTBF 440 years
30Basics
- Electromagnetic - high isolation
voltage(transformer) - long-term stability - DC
signals via AC conversion - Optical - high isolation voltage(LED/photo
transistor) - standard components (costs) -
analog drift - Capacitive - low isolation voltage - common-mode
interference -gt no relevant use
31Basics
- Working principle chopper amplifier
chopper
chopper
output stage
transformer
32Chopper Amplifier
chopper phase control
transformer
in
out
field
rectangular AC current
direct current
direct current
33Chopper Amplifier
chopper phase control
transformer
in
out
field
rectangular AC current
direct current
direct current
34Isolator Principles
3-port isolation
35Isolator Principles
2-port isolation
3-port isolation
36Isolator Principles
- Pulse Width Modulation (PWM)VariTrans P40000 /
P27000 / A26000 / P15000 / B13000
PWM converter
rectifier
output stage
input stage
transformer
37Isolator Principles
- Pulse Width Modulation (PWM)VariTrans P40000 /
P27000 / A26000 / P15000 / B13000
DIL switch
DIL switch
VariPower
output
input
Controller
PWM converter
rectifier
output stage
input stage
transformer
38Product Classification
- Product classification by function / task
39Product Classification
40Product Classification
modular housing DIN rail
41VariTrans
42VariTrans P 27000 Universal Isolators
- programmable through PWM technology ? flexible
application - calibrated range selection ? no need for manual
adjustment - mains adapter 20 ... 253 V AC/DC ? worldwide
installation - 12 mm thin (0.46 in.) ? low space requirements
43VariTrans P 27000 Universal Isolators
- input 20 mV ... 200 V 0.1mA ... 100 mA
- output 0/4 ... 20 mA, 0 ... 10 V, 20 mA,
10 V etc. - gain error 0.08 meas. val.
- cut-off frequency 10 kHz 10 Hz selectable
- test voltage 5000 V (input-output) 4000
V (output-power supply)working voltage 1000
Vsafe isolation 600 V (input-output) - power supply 20 ... 253 V ac/dc
44VariTrans P 27000
VariTrans P 27000 Universal Isolators
P27000H1 / P27000F1 86.2
P27000H1-nnnn P27000F1-nnnn 7.7
P270xxH1 / P270xxF1 6.1
45VariTrans P 27000 Universal Isolators
0
-150
20
150
46VariTrans P 26000 Universal Isolators
- input 20 mA or 10 V
- output 20 mA or 10 V
- gain error 0.1 meas. val.
- cut-off frequency 5 kHz
- test voltage 4000 Vworking voltage
1000 Vsafe isolation 300 V surge
withstand 5000 V - power supply 20 ... 253 V ac/dc
47VariTrans P 15 000 Standard Signal Isolators
- input 0 ... 20 mA / 4 ... 20 mA / 0 ... 10 V
- output 0 ... 20 mA / 4 ... 20 mA / 0 ... 10 V
- gain error 0.08 meas. val.
- cut-off frequency 10 kHz 10 Hz selectable
- test voltage 4000 Vworking voltage
1000 Vsafe isolation 300 V surge
withstand 5000 V - power supply 20 ... 253 V ac/dc
486 mm Product Series (0.24 in.)
- B10000 isolator for unipolar standard signals
- A20000 isolator for unipolar standard signals
with safe isolation - B10116 repeater power supply for 2-wire
transmitters - A20100 repeater power supply for 2-wire
transmitters, HART, switchable outputs - A20200 transmitter for temperature, strain gages
and potentiometers - P32000 transmitter for temperature, strain gages
and potentiometers, IrDA interface, SIL
approval, universal power supply - A20300 standard signal doubler
- A20400 passive isolator with up to 2 channels
49VariTrans B 10 000 Standard Signal Isolators
- input 0/4 ... 20 mA or 0 ... 10 V
- output 0/4 ... 20 mA or 0 ... 10 V
- gain error 0.3
- cut-off frequency 100 Hz
- test voltage 510 Vworking voltage
100 V - power supply 24 V dc pluggable cross-connection
for power supply
50DuraTrans M12
DuraTrans Signal Converters / Isolators
- input 0 ... 20 mA / 4 ... 20 mA / 0 ... 10 V
- output 0 ... 20 mA / 4 ... 20 mA / 0 ... 10 V
- gain error lt 0.2 measured value
- test voltage 1500 V ac
- connections M12
51High Voltage Isolator
52High Voltage Isolators VariTrans P 40000
- DC power supplies- high-power drives -
transport systems- battery systems- ... - special high-voltage applications
53High Voltage Isolators VariTrans P 40000
P 40000
P 42000D3 100V... 3600V
P 43000D2 0.1 A ... 5 A
P 41000D1 60mV... 100V
basic isolation test voltage
basic isolation test voltage
basic isolation test voltage
basic isolation test voltage
basic isolation test voltage
basic isolation test voltage
2.2 kV
3.6 kV
3.6 kV
2.2 kV
3.6 kV
2.2 kV
10 kV
15 kV
10 kV
15 kV
15 kV
10 kV
54VariTrans P 40000
High Voltages Amplifier VariTrans P 40000
- high input voltage up to 3600 V
- input current up to 5 A
- high working voltage up to 3600 V
- safe isolation up to 1800 V
- test voltage up to 15 kV
- low error 0.1 to 0.3
- compact design 22.5 / 45.0 / 67.5 mm
- CMMR 150 dB, T-CMRR 115 dB (1000V/1µs)
55Thanks a lot for your attention!