EIS Sensitivity Update - PowerPoint PPT Presentation

1 / 7
About This Presentation
Title:

EIS Sensitivity Update

Description:

Measured FL 7 efficiencies (combination of reflectivity and groove efficiency) ... Model uses a TRACE 195 Angstrom image to interpolate between quiet Sun and ... – PowerPoint PPT presentation

Number of Views:33
Avg rating:3.0/5.0
Slides: 8
Provided by: Pra8155
Category:

less

Transcript and Presenter's Notes

Title: EIS Sensitivity Update


1
EIS Sensitivity Update
John Mariska NRL 3-5 Feb 2003
2
EIS Effective Areas
  • First set of flight optics coated at Columbia
    University and Characterized at Brookhaven
  • Effective areas computed using
  • Measured M 1 reflectivities
  • Measured FL 7 efficiencies (combination of
    reflectivity and groove efficiency)
  • Same Al filter transmission as earlier
    calculations
  • Al filter mesh transmission factor of 0.85
  • Spider transmission factor of 0.80
  • CCD QE of 0.80
  • Mirror area of 0.588.4
  • Results are near those used in all earlier EIS
    sensitivity calculations

3
EIS Effective Area Curves
4
EIS Effective Area Data
  • All data files used to compute the effective area
    are in the EIS SolarSoft directory
    SSW_EIS/response
  • All data files are text, with -delimited
    comments at beginning
  • Read using data rd_tfile(file, /nocom, /auto,
    /conv)
  • Each data file has a three digit extensionhigher
    numbers are newer, so highest number of each file
    should be considered current
  • Key files are
  • EIS_EffArea_A.001 and EIS_EffArea_B.001
  • Procedure for reading effective area files will
    be placed in SSW_EIS/idl/cal and will default to
    taking highest version number of area files
  • Procedures for using emission measure curves and
    Chianti data to generate spectra for planning
    purposes under development

5
Modeling EIS
  • Using preliminary sensitivity information, have
    modeled EIS detectors
  • Model uses a TRACE 195 Angstrom image to
    interpolate between quiet Sun and active region
    differential emission measure curves
  • For each location in the TRACE image, model
    computes an emission measure and uses that to
    synthesize the spectrum along the EIS slit
  • Thermal, nonthermal, and instrumental broadening
    included
  • Includes Poisson statistics on number of arriving
    photons and converts to photoelectrons and then
    DN
  • Adds a pedestalcurrently 100 electronsand a
    normal distribution of read noise with a standard
    deviation of 6 electrons
  • Will be updating to include random Doppler shifts
    and other delights
  • Data and detailed description at
    http//tcrb.nrl.navy.mil/mariska/eismod

6
EIS Model Sample Output
7
EIS Model Implications
  • Large difference in count rates between the two
    detectors
  • For active regions and a 10 s integration, the
    model predicts
  • 10,000 to 14,000 DN for Fe XII
  • 1,500 DN for Fe XV
  • Observing strategy will need to carefully
    consider how to handle these differences
Write a Comment
User Comments (0)
About PowerShow.com