Title: String Combiner Box and String Monitoring Modules
1INDIA belive Power From Sun Green Power/Silent
Power/Econmical Power Sabco Bijlee Milegi Hum
Dekarke Rahenge
Presentation on Best Practice for Electrical
Equipment Installation and Safety of
Product(Earthing Protection)
2Solar PV Power and String Combiner Box
3String Design
4String Design
5String Design
6Electric Power Systems Lets us work till dark is
away from Each Home
Generation Transmission Distribution
Consumption
Generation
Transmission
Distribution
Load
7(No Transcript)
8(No Transcript)
9(No Transcript)
10(No Transcript)
11(No Transcript)
12(No Transcript)
13Easy to generate power as our Choice
14(No Transcript)
15An Arcing Fault is the flow of current through
the air between phase conductors or phase
conductors and neutral or ground. Concentrated
radiant energy is released at the point of arcing
an a small amount of time resulting in Extremely
High Temperature.
16(No Transcript)
17Fire Accident in Solar PV Power PlantReason Lose
Contact Earthing Disorder and Lightning
18Solar Panel Fire Accident
19More Picture Fire in Solar Pv Power Plant
20More Picture
21We are offering Surge Protection Devices as
IS/IEC 62305-4
22v
23Horrifying Losses Due To Devil Lightning
24(No Transcript)
25Sikhana to Padega Hi Follow NBC2016
26 Surge in Systems and Result
27Surge in DC Application
28(No Transcript)
29Maintenance Free - Equipment Earthing
30JMV LPS Products
31Copper Cladded Conductor For Electrical
Installation
The Copper Clad Steel Grounding Conductor is made
up of steel with the coating of 99.99 pure
copper. These conductors/ wires or strands are
equipped with the strength of steel with the
conductivity and copper with the better corrosion
resistance property. The concentric copper
cladding is metallurgic ally bonded to a steel
core through a continuous, solid cladding
process using pressure rolling for primary
bonding. The copper cladding thickness remains
constant surrounding steel. We use different
steel grades for the steel core result in Dead
Soft Annealed, High strength and Extra High
Strength Characteristics. Â The Copper Clad Steel
Wire yields a composite conductivity of 21, 30
and 40 IACS, and available in Annealed and Hard
drawn. We are delivering products with varied
conductivity and tensile strength as per the
customer need. Further, the wire can be processed
to be silver plated or tinned copper clad steel
wire.
32Most Efficient Joint Process/Fail Proof
It is efficient and superior to all existing
surface to-surface mechanical retention
connectors.
33What is Exothermic Welding System Copper to
Bi-Metal and Alumenium
- Types of Exothermic Joints
- Possible to join any bi metal except aluminum
- Exothermic welding is a process of making
maintain free highly molecular bonding process is
superior in performance connection to any known
mechanical or compression-type surface-to-surface
contact connector. Exothermic weld connections
provide current carrying (fusing) capacity equal
to that of the conductor and will not deteriorate
with age. - It offers Electrical connections between two or
more copper to copper and copper to steel
conductors. - Highly portable method as it does not require
any external power source or heat source, so it
can be done almost anywhere. - It provides strong permanent molecular bond
among metallic conductors that cannot loosen and
further will not deteriorate with age. - Connection does not corrode with time and it
offers permanent conductivity.
34Copper Clad Steel Solid ROD and Conductor
35(No Transcript)
36(No Transcript)
37(No Transcript)
38Picture in large
39JMVs Clients
40Contact Professionals for Advise
41We Protect You Use Electrical SafetyEarthing
Protection
42Contact our Team JMV INDIALeader and
Insperation behind Mr.Neeraj Saini
neeraj_at_jmv.co.inMr.Mahesh Chandra Manav Brand
JMV HOD manav_at_jmv.co.inwww.jmv.co.inMoblie
-919910398999Telecom -9191204590000